AIR FORCE A-A-59579 B-2012 TEST SET FUEL CONTROL SYSTEM - AC DC QUANTITY.pdf
《AIR FORCE A-A-59579 B-2012 TEST SET FUEL CONTROL SYSTEM - AC DC QUANTITY.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-59579 B-2012 TEST SET FUEL CONTROL SYSTEM - AC DC QUANTITY.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 AMSC N/A FSC 4920 DISTRIBUTION STATEMENT A. Approved for public release: distribution is unlimited. Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to WR-ALC/403 SCMS/GUEEA, 460 Richard Ray Bvld, Robin
2、s AFB, GA 31098-1813. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil . A-A-59579B 15 May 2012 SUPERSEDING A-A-59579A 10 May 2010 COMMERCIAL ITEM DESCRIPTION TEST SET, FUEL CONTROL SY
3、STEM - AC/DC QUANTITY The General Services Administration has authorized the use of this commercial item description (CID), for all federal agencies. 1. Scope.This Commercial Item Description ( CID ) describes an AC/DC Fuel Quantity Test Set (ADFQTS) based on Bridge Capacitance/Resistance Test Set (
4、BC/RFGTS) technology. This CID describes the minimum requirements for the ADFQTS for which only those manufacturers that meet or exceed the requirements herein are qualified per this CID. The ADFQTS will be capable of 1) measuring fuel tank resistance, capacitance and voltage, 2) simulating tank uni
5、t capacitance, 3) simulating the compensator capacitance for testing with dry fuel tanks, and 4) being utilized as a standard to calibrate the fuel measurement systems and compensator capacitance. 2. SALIENT CHARACTERISTICS. 2.1 General.The equipment shall be capable of operation and be bid sample t
6、ested within the accuracies, limits, and specifications herein. Equipment covered by this CID shall be commercially available equipment and may be modified to the extent necessary to meet the following description. The equipment shall be Class 1, in accordance with MIL-PRF-28800. 2.2. Order of Prece
7、dence.In the event of a conflict between the text of this CID and the references cited herein (except for associated detail specifications, specification sheets or MS standards) the text of this CID shall take precedence. Nothing in this CID, however, shall supersede applicable laws and regulations
8、unless a specific exemption has been obtained. 2.3 Safety. The equipment shall be UL (Underwriters Laboratories) listed and approved and/or shall comply with the safety requirements of Class 1, in accordance with MIL-PRF-28800. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking pe
9、rmitted without license from IHS-,-,-A-A-59579B 2 2.31 Intrinsic Safety. Current shall be limited to 10 milliamperes (mA) in all modes. Capacitive discharge energy shall be limited to 0.02 milli-joules at 0.016 uF for all modes of operation as stated in Boeing Specification 10-61959 for intrinsic sa
10、fety. The test set shall be tested in accordance with explosive atmosphere requirements MIL-STD-810, METHOD 511.4. 2.3.2 Leakage Current Protection.2.4 Protection shall be provided from leakage current in excess of 3.5 mA rms (AC and DC) from any accessible conductive parts of equipment (such as con
11、trol shafts with knobs broken or removed and recessed calibration or adjustment controls) to either pole of the power source for any position of the power switch. Power Consumption. 2.5 Aggregate power consumption of all components shall not exceed 200 VA. Electrical Power Sources.2.5.1 The ADFQTS,
12、when re-charging from external power sources, shall re-charge from nominal commercial, military, and shipboard power sources over the following ranges. Single-Phase, 120 Vrms.2.5.2 The ADFQTS shall re-charge using 120 Vrms, single-phase at frequencies of 50 Hz, 60 Hz, and 400 Hz in accordance with t
13、he MIL-PRF-28800 Steady-State Conditions, Transient-State Conditions, and Interruption of Power Source requirements. Single-Phase, 240 Vrms.2.6 The ADFQTS shall re-charge using 240 Vrms, single-phase at frequencies of 50 Hz and 60 Hz in accordance with the MIL-PRF-28800 Steady-State Conditions, Tran
14、sient-State Conditions, and Interruption of Power Source requirements. DC Internal Power Source.2.7 The ADFQTS shall operate from a DC internal power source in accordance with MIL-PRF-28800. The DC internal power source shall be replaceable with widely available or preferred stock listed (NSN 6140-0
15、1-213-0199) battery. Operating Temperature.2.8 The ADFQTS shall meet its performance and accuracy requirements in an operating environment of -20C to +55C. Nonoperating Temperature.2.9 General Specifications. The ADFQTS shall provide a means to determine the serviceability of Air Force aircraft empl
16、oying a variety of AC capacitance fuel gauging systems. It shall consist of a single integral unit incorporating a transportable case, direct current (DC) electrical resistance measuring circuitry, capacitance and DC voltage measuring circuitry, capacitance substitution circuitry (simulates tank uni
17、t and compensator capacitance), switches, wiring, cable assemblies, and accessories. The ADFQTS shall operate from an external AC power source and DC internal power source and shall be capable of operating while the internal power source is being charged. The structure and feature relating to calibr
18、ation shall provide for lowest cost, simplicity, accuracy and reasonable convenience in use. The ADFQTS shall meet its performance and accuracy requirements in a non-operating environment of -51C to +71C. 2.9.1 ADFQTS Functions. The ADFQTS shall contain four basic types of circuitry. Each type shall
19、 perform a separate function as described. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59579B 3 2.9.1.1 Capacitance Measurement.2.9.1.1.1 The ADFQTS shall have AC and DC capacitance measurement capability to determine the serviceability of Ai
20、r Force aircraft capacitance type fuel quantity gauging systems. The ADFQTS shall automatically display the measured capacitance, i.e., no necessary manual computation of the tank unit and the compensator. The capacitance measurement system shall have a minimum range of 0.01 pF to 39,990 pF. AC capa
21、citance readings shall have an accuracy of the greater of 0.1% of the reading or 0.05 pF. DC capacitance readings shall have an accuracy of the greater of 0.2% of the reading or 0.05 pF. The resolution shall be at least 0.005% of the range selected. Rectified wave (DC) Capacitance Measurement.2.9.1.
22、2 The ADFQTS shall have an additional capability for capacitance measurement of peculiar aircraft fuel measurement systems where in-line diodes are used in the tank units. The ADFQTS shall automatically display the measured capacitance, i.e., no necessary manual computation of the tank unit and the
23、compensator. Simulated Tank Unit Capacitance.2.9.1.3 The ADFQTS shall be able to simulate tank unit capacitance in the range from 0 to 9,990 pF or greater. The capacitance simulation shall have an accuracy of at least 0.2% or 0.2 pF whichever is larger. Simulated Compensator Capacitance. 2.9.1.4 The
24、 ADFQTS shall be able to simulate Compensator capacitance in the range from 0 to 990 pF or greater. The capacitance simulation shall have an accuracy of at least 0.2% or 0.2 pF whichever is larger. Simulated Auxiliary (Aux) Capacitance. 2.9.1.5 The ADFQTS shall be able to simulate Aux capacitance ac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA59579B2012TESTSETFUELCONTROLSYSTEMACDCQUANTITYPDF

链接地址:http://www.mydoc123.com/p-427124.html