1、9999974 OLbLOBO 526 A-A-59 127 October 15, 1997 COMMERCIAL ITEM DESCRIPTION Generator, Signal, VORALS, AN/ARM-180 The General Services Administration has authorized the use of this commercial item description (CID) for ali federal agencies. 1. SCOPE. This commercial item description covers a VOR/ILS
2、 signal generator. This CID is meant as a minimum requirement for the VOR/ILS signal generator in which only those manufacturers that meet or surpass the following requirements are qualified per this CID. This signal generator shall produce both rf and audio signals for testing VOR, localizer, glide
3、slope, and marker beacon signals. 2. SALIENT CHARACTERISTICS. 2.1 The equipment shall meet Class 3 requirements of MIL-PFW-28800 and be bid sample tested within the accuracies, limits, and specifications herein. 2.2 Environmental requirements. 2.2.1 Temperature requirements. The product shall meet i
4、ts performance and accuracy requirements in an operating temperature of +1O“C to +40“C and non-operating -20C to +65“C. 2.2.2 Electromaanetic interference (EMI). The equipment shall comply with the EMI requirements specified for Class B equipment in MIL-STD-46 1 , excluding tests CE06, CE07 and modi
5、 tests RE02, RS03 as follows. a. RE02 full limits to 10 times the highest used or intentionally generated fkequency or 1 GHz whichever is greater. b. RS03 full limits to 1 GHz. Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this docum
6、ent should be sent to: Technology k2.0 dB for RF output level from -60 to -120 be supplied both separately and together; be of sufficient magnitude to modulate the carrier to a preset depth of 40% and a variable range from 10 to 80% AM; vary simultaneously and proportionately. 2.11.3.4 90/150 Hz pha
7、se error. The phase error of the 90 and 150 Hz signals shall not exceed 1.0“. Relative phase is defined as the difference in 30 Hz degrees of the points at which the 90 Hz and the 150 Hz wave form crosses the zero axis in the same direction at the same time. 2.1 1.3.5 DDM control. The output ratio o
8、f the 90 Hz signals shall have presets at 0.000,0.175 and 0.400 +0.001 DDM, at both 90 Hz predominant and 150 Hz predominant for all settings except 0.000 DDM. For purposes of determining DDM, the base shall be 0.40 for the GS function. 2.1 1.3.5.1 Variable DDM control. A control shall be provided t
9、o continuously vary the DDM from 0.800 k.001 DDM, 90 Hz predominant to 0.800 S.001 DDM, 150 Hz predominant. This control shall have an off position in which the variable DDM circuitq is not operative. 2.1 1.3.6 90 Hz and 150 Hz delete. Two front panel controls shall be provided to delete the 90 and
10、150 Hz tones independently or simultaneously. 2.12 LOCALIZER GENERATOR. 2.12.1 Localizer shall be supplied both separately and together; shaii be of sufficient amplitude to modulate the canier to a preset depth of 10% and a variable range from 5 to 40% AM; shall vary simultaneously and proportionate
11、ly. 2.12.3.4 90 Hz and 150 Hz phase error. The phase error of the 90 Hz and 150 Hz signals shall be as specified in 2.1 1.3.4. 2.12.3.5 DDM control. The output ratio of the 90 Hz and 150 Hz signals shall have presets at 0.000,0.046,0.093,0.155, and 0.200 kO.001 DDM, for both 90 Hz dominant and 150 H
12、z predominant for all signals except 0.000 DDM. For purposes of determining DDM, the base shall be 0.20 when the function selector is in the LOC function. 2.12.3.5.1 Variable DDM control. A control shall be provided to continuously vary the DDM fiom 0.400 M.001 DDM 90 Hz predominant to 0.400 M.001 D
13、DM 150 Hz predominant. This control shall have an off position in which the variable DDM circuitry is not operative. 2.12.3.6 90 Hz and 150 Hz delete. Front panel controls shall be provided to delete the 90 Hz and 150 Hz tones independently and simultaneously. 2.12.3.7 ID tone. The 1020 Hz signal sh
14、all amplitude modulate localizer frequencies, either separately or with the LOC modulation present and shall be selectable by a front panei ON-OFF control or function selector. 2.12.3.7.1 Modulation. The depth of modulation of the localizer frequencies by the 1020 Hz signal shall be fixed at a modul
15、ation level of 30.0% S.5% with 4.0% RF tone distortion. 2.13 VHF Omnirange penerator. 2.13.1 VOR nenerator selection. The VOR signai generator shail be selected by means of an ON- OFF control located on the front panel. 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA591271997GENERATORSIGNALVORILSANARM180 信号发生器 VORILSANARM180PDF

链接地址:http://www.mydoc123.com/p-427039.html