1、A-A-58001 1 JUNE 1992 COMMERCIAL ITEM DESCRIlTION GENERATOR, SIGNAL, DIGITAL WORD The General Services Administration has authorized the use of this Commercial Item Description. Abstract. This Description (CID) describes a Digital Signal Generator, This CID is meant as a minimum requirement for the
2、Digital Signal Generator in which only those manufacturers that meet or surpass the following requirements are qualified per this CID. Classification. Equipment covered by this CID shall be commercially a available following description. equipment and may be modified to the extent necessary to meet
3、the MIL-T-28800. The equipment shall meet the following paragraphs of MIL-T-28800. Paragraph 1.2.2 1.2.4 3.6.5.1 3.7.4.1 3.8.3 3.9.3.1 3e9.3e1.2 Title Class 5 Color R Enclosure Form, Style E Vibration, sinuosoidal, Class 5 EM1 I Type III Accessible Potentials Type III Leakage Current Protection, Typ
4、e III Order of Precedence. In the event of a conflict between the text of this CID and the references cities herein (except for associated detail specifications, specification sheets or MS standards) the text of this CID shall take prgcedence. Nothing in this CID, however, shall supersede applicable
5、 laws and regulations unless a specific exemption has been obtained. Salient Characteristics. The equipment shall be capable of operation and bid sample tested within the accuracies, limits, and specifications herein. Safety and Environmental. The equipment shall meet all safety and environmental re
6、quirements as specified in MIL-T-28800 for the classification as stated herein. Electrical Power Sources. commercial, military, and shipboard power sources of 1151230 volts AC (+ 10%) at line frequencies of 45 Rz to 66 Rz. watts. classification specified herein. The equipment shall operate from nomi
7、nal Power consumption shall not exceed 630 Transient state conditions shall meet MIL-T-28800 requirements for the Beneficial comment (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should Technology Distribution is unlimited. Provided by
8、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58001 lab m 9999974 00b5560 5 m A-A-58001 Temperature Requirements. a. Operatine, temperature. The equipment shall meet its performance and accuracy requirements in an operating environment of O C to +50 C. b.
9、Nonoperating temperature. The equipment shall meet its performance and accuracy requirements in an nonoperating environment of -40 C to +65 C. Mean Time Between Failures (MTBF). The equipment Mean Time Between failures (MTBF) shall be 2,000 hours. The lower test MTBF shall be 2,000 hours and the upp
10、er test MTBF shall be 4,000 hours. Pre-conditioning requirement. Each deliverable equipment shall be capable of being subjected to the environmental screening effects of burn in and thermal cycling, with thermal cycling being accomplished in the sample testing phase. Calibration and maintenance adju
11、stment. The design of the system shall provide for readily accessible calibration adjustments and maintenance adjustment. These adjustment shall be provided by variable value components which are adjustable by the use of simple means, of selected components or parts is unacceptable unless specifical
12、ly approved. The calibration adjustable, wherever possible, shall be accessible without removal of the instrument case or modules. The calibration on interval shall be a period of one year or greater based on an operating time of 2000 hours. The calibration by substitution Performance characteristic
13、s. The Digital Signal Generator shall have at least eight parallel channels which meet the requirements listed below and unless otherwise specified, all vernier controls shall be in the calibrated position and all performance requirements shall apply after a 30 minute warm up period in a laboratory
14、ambient operating temperature. Two of the eight channels shall have a minimum data rat of 100 Mbits/S in the serial mode with an even number of bits. All eight channels shall have a minimum data rate of 50 Nbits/S in the parallel mode. Electrical function specification. Unless otherwise specified th
15、e Digital Signal Generator shall meet the following minimum requirements: ECL Drivers: The ECL Drivers shall drive to a logic “low“ of less or equal to -1.6OV and shall drive to a logic “highif of greater than or equal to -1.02v. Rise and Fall Times: The rise and fall times for inputs shall not exce
16、ed 3 nano seconds (ns). Skew: The Skew between channels shall be less than or equal to 6 ns. Internal Clock. The internal clock shall have a programmable period from 20 nsec to 999 usec and shall be derived from either the system clock or an external clock. Digitally Generatad Internal Clock Range a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA580011992GENERATORSIGNALDIGITALWORD 数字 信号发生器 PDF

链接地址:http://www.mydoc123.com/p-426896.html