AIIM MS17-2001 Information and Image Management - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use《信息和图像管理-缩微摄影术-循环的(流量)缩微胶卷的测试图表和指标.pdf
《AIIM MS17-2001 Information and Image Management - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use《信息和图像管理-缩微摄影术-循环的(流量)缩微胶卷的测试图表和指标.pdf》由会员分享,可在线阅读,更多相关《AIIM MS17-2001 Information and Image Management - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use《信息和图像管理-缩微摄影术-循环的(流量)缩微胶卷的测试图表和指标.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、ANSVAIIM MS17-2001 American National Standard for Information and Image Management - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use An American National Standard prepared by The Association for Information and Image Management International Approved
2、as an American National Standard May 4, 2001 Abstract: This standard describes specifications for creating and using a test chart and a test target for rotary (flow) microfilm cameras and a method for evaluating the photographic quality and mechanical performance of rotary microfilm cameras. ANSI/AI
3、IM MS17-2001 - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use Contents . P a g e Foreword . III . Scope and purpose I Normative references . 1 Definitions . 2 Content of the test cha 3 Method for using the test cha . 8 Method for using a white paper
4、test . 11 Table BI Rotary microfilm camera: Approximate number of document images per 30.5 meter (100.0 foot) roll of film 21 Fig u res 1 Rotary camera test chart . 4 2 Reproduction of a photomicrograph showing an example of acceptable resolved test pattern (8.0) 9 Annexes A (Informative) An example
5、 of a completed test report form 13 AI (informative) Blank test report form . 15 B (informative) Resolution and capstan check . 17 II ASSOCIATION FOR INFORMATION AND IMAGE MANAGEMENT INTERNATIONAL ANSI/AIIM MS17-2001 - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descr
6、iptions and Use Foreword (This foreword is not a part of American National Standard for Information and Image Management - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use. ANSVAIIM MS17-2001.) This standard describes a methodology for determining seve
7、ral aspects of the optical quality of rotary microfilm cameras, permitting comparisons of products designed for the same purpose. Evaluations of how consistent a single cameras quality is over time is also included. This standard features editorial revisions of ANSVAIIM MS17-I 992 and supercedes edi
8、tions previously published in 1992,1983 and 1977. Two annexes are included with this standard, annex A. An example of a completed test report form (also annex AI, Blank test report form), and annex B, Resolution and capstan check. These annexes are informative annexes, and are not a part of the stan
9、dard. Physical test charts are used in the methodology covered in this standard. The wide variety of material now being microfilmed with this type of equipment, from overwritten tissue copies through checks, letters, carbons, and long graphical material, has indicated the use of “generic” test chart
10、s. The use of such generic charts will provide valid comparison of equipment and mechanical/optical conditions, making it possible to select or optimize the choice of film, processing, size of type font, etc., for any specific installation. A chart can also be used to ensure continuous quality of mi
11、crofilming or to help locate specific equipment malfunctions. Chart materials specified are both paper and heavy-duty, cleanable plastic film, giving users a selection that is, as nearly as possible, compatible with their system control problems. The charts do not purport to be typical in image cont
12、ent or contrast, stiffness or weight. Rather, they are tools to be used to determine machine performance. Remember other factors-the type of microfilm used and the type of film processing, for example-also have a major effect on the appearance of the recorded chart and must be considered fully when
13、evaluating the resulting images. The charts and test methodology described here enable the user to measure photographic quality and mechanical performance of 16mm flow cameras. The test charts include a variety of type sizes. The overall dimension of the rotary camera test chart is 216 mm X 297 mm (
14、8.5 inch X 11.7 inch). This test chart can be trimmed to metric A4 size of 210 mm X 297 mm (8.3 inch X 11.7 inch) or “A letter size of 216 mm X 279 mm (8.5 inch X 11.0 inch). These sizes were selected not only because of trends toward the use of metric sizes in the U.S., but in recognition of the gr
15、owing use of American equipment in areas employing metric-size originals. Obtaining the charts XI12 Rotary Camera Test Chart (Plastic) and XI13 Rotary Camera Test Chart (Paper) are available separately from this standard from the Association for Information and Image Management (AIIM), Publication S
16、ales, 1100 Wayne Avenue, Silver Spring, Maryland 20910; (301) 587-8202; fax: (301) 587-271 1 and other sources. References in the text to the plastic and paper charts refer to XI 12 and XI 13, above. The charts are nof standards. ASSOCIATION FOR INFORMATION AND IMAGE MANAGEMENT INTERNATIONAL ANSI/AI
17、IM MS17-2001 - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use This standard is divided into three sections: 1) Specification for creating a chart, including size, materials, and quality. 2) Method for using the chart, which covers microimage quality,
18、 mechanical performance, correlation of optical and mechanical performance, reduction, and, in an annex, resolution and capstan check. 3) Method for using a white paper (blank) target with an explanation of test report forms Suggestions for improvement of this standard are welcome. They should be se
19、nt to the Chair, AIIM Standards Board, Association for Information and Image Management, 1100 Wayne Avenue, Silver Spring, Maryland 2091 0-5699. At the time it approved this standard, the AIIM Standards Board had the following members: Name of Representative Organization Represented Herbert J. White
20、, II, Chair Genealogical Society of Utah Robert Breslawski Eastman Kodak Company Betsy Fanning Association for Information and Image Management International William Neale U.S. TAG to TC 171 Louis H. Sharpe, II Picture Elements Technologies Herman Silbiger APPLICOM, Inc. Christopher D. Thompson Reco
21、gnition Research, Inc. The AIIM Micrographics Quality and Control Committee, CIO, had the following members at the time it reviewed, revised, and approved this standard. Name of Organization Represented Rep rese n tat ive Michael J. Badal Badal Associates Jan Bastien Agfa Gevaert NV Sandra Behel Ene
22、rgen Corporation John Breeden Virginia Retirement Systems Robert Breslawski, Chair Adele Carboni, CRM Gateway 2000 Eastman Kodak Company IV ASSOCIATION FOR INFORMATION AND IMAGE MANAGEMENT INTERNATIONAL ANSI/AIIM MS17-2001 - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target -
23、 Descriptions and Use Myron Chace Richard R. Conger Walter Cybulski Suzanne Dodson Eric Erickson W. Camden Gass Bruno Glavich John Glover Richard M. Harrington Jack W. Hostettler Clara Jehle Virginia Jones, CRM Paul Kafun Jan Kinzer Theresa Maultsby Whit Minkler Paul G. Montgomery Ted Montuori Rober
24、t Mottice William Neale Eugene Pawlowski Robert Phelan Robert M. Saholsky George Sedun Joseph Steffen Tamara Swora Ron Throunk Mike VanDamme Herbert J. White, II Library of Congress Conger Consultants National Library of Medicine University of British Columbia Genealogical Society of Utah Deere 2) d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIIMMS172001INFORMATIONANDIMAGEMANAGEMENTMICROGRAPHICSROTARYFLOWMICROFILMCAMERATESTCHARTANDTESTTARGETDESCRIPTIONSANDUSE

链接地址:http://www.mydoc123.com/p-426764.html