AHRI IWH-TS-1-2003 PERFORMANCE OF INDIRECT-FIRED WATER HEATERS - TESTING STANDARD.pdf
《AHRI IWH-TS-1-2003 PERFORMANCE OF INDIRECT-FIRED WATER HEATERS - TESTING STANDARD.pdf》由会员分享,可在线阅读,更多相关《AHRI IWH-TS-1-2003 PERFORMANCE OF INDIRECT-FIRED WATER HEATERS - TESTING STANDARD.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、Indirect-Fired Water Heater Testing Standard IWH-TS-1 March 2003 GAMA TESTING STANDARD Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition Sponsored by Gas Appliance Manufacturers Association, Inc. Arlington, Virginia 22201 Telephone: (703) 525-7060 Program Administrat
2、or Gas Appliance Manufacturers Association, Inc. Hydronics Institute Division Rating Program Berkeley Heights, New Jersey 07922-0218 Telephone: (908) 464-8200 024 Indirect-Fired Water Heater Testing Standard IWH-TS-1 - March 2003 2 TESTING STANDARD Method to Determine Performance of Indirect-Fired W
3、ater Heaters TABLE OF CONTENTS Section 1 Purpose. 1 Section 2 Scope 1 Section 3 Definitions 1 Section 4 Instruments 3 Section 5 Apparatus 3 Section 6 Test Condition . 5 Section 7 Test Procedure 9 Section 8 Data To Be Recorded 12 Section 9 Calculations. 12 Section 10 Test Report 15 FIGURES 1 Example
4、Of Test Setup . 6 2 Example Of Test Setup When Mixing Valve Is Used 7 FORMS IWH-TS-1 Indirect-Fired Water Heater Volume Log. 17 IWH-ST-1 Indirect-Fired Water Heater Standby Test Log 18 IWH-CD-1 Indirect-Fired Water Heater Continuous Draw Test 19 IWH-FD-1 Indirect Water Heater First Draw Test. 20 IWH
5、-R-1 Indirect-Fired Water Heater Report Sheet. 21 TABLES 3 Density Of Water. 22 Exibit A Least Square Method For A Straight Line Through A Series Of Points 23 Indirect-Fired Water Heater Testing Standard IWH-TS-1 - March 2003 3 TESTING STANDARD Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER
6、 HEATERS March 2003 Edition 1.0 PURPOSE To establish a method of test to determine the performance of Indirect-Fired Water Heaters; both Indirect-Fired Storage Waters Heaters and Indirect-Fired Instantaneous Water Heaters. 2.0 SCOPE 2.1 This test method is intended to apply to Indirect-Fired Water H
7、eaters designed for installation with a hot water boiler or some other external source of heated water. 2.2 This standard is limited to Indirect-Fired Water Heaters having a total volume (potable plus heat source) of 120 gallons or less. 2.3 This standard does not apply to direct-fired instantaneous
8、 or storage water heaters, direct fired instantaneous water heaters, tankless water heaters, or heat pump water heaters. 3.0 DEFINITIONS COMBINATION SPACE HEATING AND WATER HEATING APPLIANCE - A unit designed to provide space heating and potable water heating from a single primary energy source. HOT
9、 WATER STORAGE TANK - A tank used to store heated, potable water. INDIRECT-FIRED STORAGE WATER HEATER - A water heater consisting of a potable hot water storage tank equipped with an internal or external heat exchanger used to transfer heat to the stored potable water from an external source. INDIRE
10、CT-FIRED INSTANTANEOUS WATER HEATER - A water heater consisting of a tank which contains hot water from an external source and a heat exchanger used to transfer heat from this stored water to the potable water. TANKLESS WATER HEATER - A heat exchanger for indirect heating of domestic water, designed
11、 to be used without a Indirect-Fired Water Heater Testing Standard IWH-TS-1 - March 2003 4 domestic water storage tank. It may be attached directly to the boiler, or installed external to the boiler and connected by piping. THERMOSTAT, TANK - A device which senses changes in stored water temperature
12、, and controls by means of separate components, the flow of energy to maintain selected temperatures. 3.1 NOMENCLATURE cpSpecific heat of water, Btu per pound F DR Mean tank water temperature decay rate during standby test, F per hour DRuUncorrected mean tank water temperature decay rate during stan
13、dby test, F per hour Q Standby heat loss from the Indirect-Fired Water Heater tank in Btu/hr QhHeat exchanger heat input for indirect-fired storage water heater, Btu per hour TaMeasured ambient air temperature, F TcCold water supply temperature, F TiMeasured potable water inlet temperature, F Ti,avg
14、Average potable water inlet temperature, F TihInlet heat source water temperature to the Indirect-Fired Water Heater, F Tih,avgAverage inlet heat source water temperature to the Indirect-Fired Water Heater, F ToMeasured potable water outlet temperature, F To,avgAverage potable water outlet temperatu
15、re, F TohOutlet water temperature from Indirect-Fired Water Heater to heat source, F Toh,avgAverage outlet water temperature from Indirect-Fired Water Heater to heat source, F To(max)Maximum potable water outlet temperature, draw test, F TsMean tank temperature, F V Potable water volume for indirect
16、-fired storage water heater, gallons VcVolume of potable water drawn during continuous draw test, gallons per 30 minutes VcdContinuous draw rating, gallons per hour VdVolume of potable water drawn duing the first draw test, gallons V(end)Volume reading of potable water meter at end of first draw tes
17、t, gallons VfFirst hour rating, gallons per hour VhHeat source water volume for indirect-fired storage water heater, gallons Vt Initial volume reading of potable meter reading at begining of first draw test, gal w Water flow rate (potable) in Indirect-Fired Water Heater, gallons per minute whWater f
18、low rate (heat source) for Indirect-Fired Water Heater, gallons per minute wh,avgAverage water flow rate (heat source) for Indirect-Fired Water Heater, gallons per minute WcTotal weight of potable water drawn during continuous draw test, pounds per 30 minutes WdTotal weight of potable water drawn du
19、ring first draw test, pounds WpWeight of tank when filled with potable water, pounds WphWeight of tank when filled with potable and heat source water, pounds WtDry weight of tank, pounds WT(end)Weight of weigh tank and potable water at end of first draw test, pounds Indirect-Fired Water Heater Testi
20、ng Standard IWH-TS-1 - March 2003 5 WTtInitial weight of weigh tank at beginning of first draw test, pounds Density of water, pounds per gallon (see Table 3) 4.0 INSTRUMENTS 4.1 GENERAL All instruments shall be in working order and be calibrated periodically. Records of periodic calibration shall be
21、 kept and they shall contain, at a minimum, the date of calibration, method of calibration, and reference standard used. 4.2 TEMPERATURE 4.2.1 THERMOMETERS Shall have an error no greater than 1F. 4.2.2 THERMOCOUPLES Unless otherwise specified herein, thermocouples and their read out instrumentation
22、shall have an error no greater than 0.2F for all readings. Thermocouples shall be the bead type having a wire size no greater than No. 24 American Wire Gauge (AWG). Water temperatures thermocouples shall be the immersion type. The meter for reading the temperature shall have 0.1F graduations 4.3 PRE
23、SSURE Water pressure measuring instruments shall be calibrated so that the error is not greater than 1 pound per square inch. 4 .4 WEIGHT OR VOLUME The error associated with the measuring instruments shall not exceed 0.5 percent of the quantity measured. 4.5 TIME The error associated with timing ins
24、truments shall not exceed 0.5 seconds per hour. 4.6 WATER FLOW RATE A flow meter, if used, shall be calibrated so that the error is no greater than 0.5 percent of the hourly rate. 5.0 APPARATUS The apparatus described below is used in conjunction with Indirect-Fired Water Heaters during the testing.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRIIWHTS12003PERFORMANCEOFINDIRECTFIREDWATERHEATERSTESTINGSTANDARDPDF

链接地址:http://www.mydoc123.com/p-422626.html