AHRI GUIDELINE Q-2016 Content Recovery & Proper Recycling of Refrigerant Cylinders.pdf
《AHRI GUIDELINE Q-2016 Content Recovery & Proper Recycling of Refrigerant Cylinders.pdf》由会员分享,可在线阅读,更多相关《AHRI GUIDELINE Q-2016 Content Recovery & Proper Recycling of Refrigerant Cylinders.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 AHRI Guideline Q 2016 Guideline for Content Recovery & Proper Recycling of Refrigerant Cylinders Price $10.00 (M) $20.00 (NM) Copyright 2016, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY RECOMMENDAT
2、IONS It is strongly recommended that the product be designed, constructed, assembled and installed in accordance with nationally recognized safety requirements appropriate for products covered by this guideline. AHRI, as a manufacturers trade association, uses its best efforts to develop guidelines,
3、 employing state-of-the-art and accepted industry practices. However, AHRI does not certify or guarantee safety of any products, components or systems designed, tested, rated, installed or operated in accordance with these guidelines or that any tests conducted under its guidelines will be non-hazar
4、dous or free from risk. Note: This guideline supersedes AHRI Guideline Q-2010. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope . 1 Section 3. Definitions . 1 Section 4. Responsibilities . 2 Section 5. Procedure 2 FIGURES Figure 1. Placement of Screwdriver for Piercing . 2 Figure
5、 2. Pierce Rupture Disc . 3 Figure 3. Open Rupture Disc 3 Figure 4. Placement of Non-sparking Pick for Piercing . 3 Figure 5. Pierce Side of Tank . 4 Figure 6. Label Pierced Hole 4 APPENDICES Appendix A. References Normative . 5 Appendix B. References Informative 5 AHRI GUIDELINE Q-2016 1 CONTENT RE
6、COVERY AND PROPER RECYCLING OF REFRIGERANT CYLINDERS Section 1. Purpose 1.1 Purpose. For practical, safety and environmental reasons, there is a need for content recovery and proper recycling of refrigerant cylinders. This document is a guideline for content recovery and recycling of cylinders at th
7、e end of their useful service life. This document is not intended to be an exhaustive listing of all good practices or requirements. Applicable federal, state and local requirements should be reviewed. 1.1.1 Intent. This guideline is intended for the guidance of the industry, including manufacturers
8、, engineers, installers, contractors, users, refrigerant reclaimers and metal recyclers 1.1.2 Review and Amendment. This guideline is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This guideline is applicable to all U.S Department of Transportation (DOT) non-ref
9、illable and refillable fluorocarbon refrigerant cylinders, as defined in Section 3, having water capacity greater than two pounds used to transport refrigerants sold in the United States. 2.2 Exclusions. This guideline does not apply to drums used to ship refrigerants. Section 3. Definitions All ter
10、ms in this document will follow the standard industry definitions in the ASHRAE Terminology website (https:/www.ashrae.org/resources-publications/free-resources/ashrae-terminology) unless otherwise defined in this section. 3.1 DOT-39 Non-refillable Cylinder. A single-use container produced in accord
11、ance with Title 49, Code of Federal Regulations, Section 178.65. 3.2 DOT Refillable Cylinder. A refillable container produced in accordance with the Title 49, Code of Federal Regulations, Section 178.36 (DOT 3A), 178.37 (DOT 3AA), 178.51 (DOT 4BA) or 178.61 (DOT 4BW) or as specified in an applicable
12、 special permit authorization as provided by the cylinder manufacturer. 3.3 Empty State. 3.3.1 Non-refillable Cylinder. A cylinder whose contents have been evacuated to a vacuum of 15 in Hg, relative to standard atmospheric pressure of 29.9 in Hg. 3.3.2 Refillable Cylinder. A cylinder whose contents
13、 have been recovered to an internal pressure of 0 psig or less with the intent to return it to the owner for proper handling. 3.4 End User. The individual or entity that renders the cylinder empty as defined in Section 3.3. 3.5 Metal Recycler. A business or organization that processes or recycles in
14、dustrial consumed scrapped material in a sound, environmentally responsible manner. 3.6 Recover. To remove refrigerant from a cylinder at the end of its useful service life and store it in a properly pressure rated recovery cylinder. 3.7 Should. “Should“ is used to indicate provisions which are not
15、mandatory but which are desirable as good practice. 3.8 Special Permit Cylinder. A cylinder that has been authorized by the DOT to be manufactured outside the scope of existing DOT regulations but in accordance with the requirements specified by DOT in a special permit. The requirements in AHRI GUID
16、ELINE Q-2016 2 the special permit may include design, composition, manufacture, testing, marking, and transportation criteria as well as special provisions. Section 4. Responsibilities 4.1 Responsibilities. It is the responsibility of the End User to verify that any residual refrigerant contents are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRIGUIDELINEQ2016CONTENTRECOVERYPROPERRECYCLINGOFREFRIGERANTCYLINDERSPDF

链接地址:http://www.mydoc123.com/p-422618.html