AHRI 810 I-P-2012 Performance Rating of Automatic Commercial Ice-Makers.pdf
《AHRI 810 I-P-2012 Performance Rating of Automatic Commercial Ice-Makers.pdf》由会员分享,可在线阅读,更多相关《AHRI 810 I-P-2012 Performance Rating of Automatic Commercial Ice-Makers.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 2012 Standard for Performance Rating of Automatic Commercial Ice-Makers Approved by ANSI on June 12, 2013 ANSI/AHRI Standard 810 (I-P) Price $15.00 (M) $30.00 (NM) Copyright 2012, by Air-Conditioning, Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademar
2、k Office IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed,
3、 constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry pra
4、ctices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. AHRI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program The Certification Program includes all Automatic Commercial Ice-Makers as defined in Se
5、ction 3 and includes all Ice Storage Bins as defined in Section 3 of AHRI Standard 820 (I-P)-2012, Performance Rating of Ice Storage Bins. Certified Ratings The following Certification Program ratings are verified by test at the Standard Rating Conditions: a. Ice Harvest Rate, lb/24 h b. Potable Wat
6、er Use Rate, gal/100 lb of ice (Batch Type Ice-Makers only) c. Condenser Water Use Rate, gal/100 lb of ice d. Energy Consumption Rate, kWh/100 lb of ice e. Bin Theoretical Storage Capacity, lb (Self-Contained Model Ice-Makers only) f. Ice Hardness Factor, % (Continuous Type Ice-Makers only) Note: Th
7、is standard supersedes AHRI Standard 810-2007 with Addendum 1. For SI ratings, see AHRI Standard 811 (SI)-2012. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope . 1 Section 3. Definitions. 1 Section 4. Test Requirements 2 Section 5. Rating Requirements . 3 Section 6. Minimum Data
8、 Requirements for Published Ratings . 4 Section 7. Marking and Nameplate Data . 4 Section 8. Conformance Conditions 4 APPENDICES Appendix A. References Normative 5 Appendix B. References Informative 5 ANSI/AHRI STANDARD 810 (I-P)-2012 1 PERFORMANCE RATING OF AUTOMATIC COMMERCIAL ICE-MAKERS Section 1
9、. Purpose 1.1 Purpose. The purpose of this standard is to establish for Automatic Commercial Ice-Makers: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intend
10、ed for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to factory-made Automatic Commercial Ice-
11、Makers as defined in Section 3. Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki) unless otherwise defined in this section. 3.1 Automatic Commercial Ice-Maker(ACIM). A factory-m
12、ade assembly (not necessarily shipped in one package) including a condensing unit and ice-making section operating as an integrated unit, with means for making and harvesting ice. It is an assembly that makes no less than 50 lbs of ice per day and up to 4,000 lbs of ice per day at Standard Ratings C
13、onditions and may also include means for storing or dispensing ice, or both. 3.1.1 Combined Ice-Maker and Dispenser. A machine that makes and dispenses ice. 3.1.2 Continuous Type Ice-Maker. An ACIM that continually freezes and harvests ice at the same time. 3.1.3 Batch Type Ice-Maker. An ACIM that h
14、as alternate freezing and harvesting periods. 3.1.4 Self-Contained Model Ice-Maker. A model in which the ice-making mechanism and storage compartment are in an integral cabinet. 3.1.5 Split System Ice-Maker. A model in which the ice-making mechanism and condenser or condensing unit are in separate s
15、ections. 3.1.5.1 Remote Condensing Unit Systems. A type of ACIM that has a condenser and compressor remote from the ice-making mechanism section. 3.1.5.2 Remote Condenser Systems. A type of ACIM in which the ice-making mechanism with compressor and condenser are in separate sections. 3.2 Bin Theoret
16、ical Storage Capacity. For Self-Contained Model Ice-Makers only, the theoretical storage capacity and the storage effectiveness of the ice storage bin shall be determined in accordance with AHRI Standard 820 (I-P). For these models, the internal volume is the volume calculated up to the intended shu
17、t-off level. The intended shut-off level is defined as the height of the thermostat bulb; the bottom of the curtain or the height of the electric eye, depending upon the mechanism used to shut off the Ice-Maker. 3.3 Condenser Water Use Rate. The amount of water used by the condensing unit (if water
18、cooled) according to ASHRAE Standard 29, expressed in 1 gal/100 lb of ice, stated in multiples of 1 gal/100 lb of ice. ANSI/AHRI STANDARD 810 (I-P)-2012_ 2 3.4 Dump or Purge Water: The water from the ice making process that was not frozen at the end of the freeze cycle and is discharged from the mac
19、hine for a Batch Type Ice-Maker. Note: This is a departure from the term as defined by ASHRAE Standard 29 but is more functional for ACIM testing purposes. 3.5 Energy Consumption Rate. Total energy input rate according to ASHRAE Standard 29, expressed in kWh/100 lb of ice stated in multiples of 0.1
20、kWh/100 lb of ice. For Split System Ice-Makers, total power input shall include condenser fan power. 3.6 Harvest Water: The water that has been collected with the ice used to measure the machines capacity. 3.7 Ice Hardness Factor. For Continuous Type Ice-Makers only, the ice hardness is defined in A
21、SHRAE Standard 29 based on Net Cooling Effect, %. = /144 1005T3.8 Ice Harvest Rate. The gross weight of ice harvested according to ASHRAE Standard 29, expressed in lb/24 h and in multiples of 1 lb/24 h. 3.9 Net Cooling Effect. Heat transfer per pound of ice to change the state of ice from its initia
22、l state as produced by the ACIM to a liquid state at 32F, Btu/lb. 3.10 Potable Water Use Rate. The amount of potable water used in making ice according to ASHRAE Standard 29, which is equal to the sum of the ice harvested, Dump or Purge Water, and the Harvest Water in gal/100 lb of ice, expressed in
23、 multiples of 0.1 gal/100 lb of ice. Alternatively, the amount of water entering the ACIM per cycle can be measured. 3.11 Published Rating. A statement of the assigned values of those performance characteristics, under stated rating conditions, by which a unit may be chosen to fit its application. T
24、hese values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the ratings of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manuf
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI810IP2012PERFORMANCERATINGOFAUTOMATICCOMMERCIALICEMAKERSPDF

链接地址:http://www.mydoc123.com/p-422582.html