AHRI 490 I-P-2011 Performance Rating of Remote Mechanical-Draft Evaporatively-Cooled Refrigerant Condensers.pdf
《AHRI 490 I-P-2011 Performance Rating of Remote Mechanical-Draft Evaporatively-Cooled Refrigerant Condensers.pdf》由会员分享,可在线阅读,更多相关《AHRI 490 I-P-2011 Performance Rating of Remote Mechanical-Draft Evaporatively-Cooled Refrigerant Condensers.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 2011 Standard for Performance Rating of Remote Mechanical- Draft Evaporatively- Cooled Refrigerant Condensers AHRI Standard 490 (I-P) Price $10.00 (M) $20.00 (NM) Copyright 2011, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademar
2、k Office IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed,
3、 constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry pra
4、ctices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ARI Standard 490-2003. For the SI version, see AHRI Standard 491 (SI) 2011 TABLE OF CONTENTS SECTION PAGE Section 1. Purpose .1 S
5、ection 2. Scope 1 Section 3. Definitions 1 Section 4. Test Requirements 2 Section 5. Rating Requirements 3 Section 6. Calculations 3 Section 7. Minimum Data Requirements for Published Ratings .4 Section 8. Marking and Nameplate Data .5 Section 9. Conformance Conditions 5 TABLE Table 1. Standard Rati
6、ng Conditions 3 APPENDICES Appendix A. References - Normative 6 Appendix B. References - Informative 6 AHRI STANDARD 490 (I-P)-2011 1 PERFORMANCE RATING OF REMOTE MECHANICAL-DRAFT EVAPORATIVELY-COOLED REFRIGERANT CONDENSERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish
7、 for Remote Mechanical-Draft Evaporatively-Cooled Refrigerant Condensers (Evaporative Condensers): definitions; test requirements; rating requirements; calculations; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard i
8、s intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Evaporative Condensers as defi
9、ned in Section 3 of this standard and is limited to Halocarbon Refrigerants and ammonia (R-717), for use with or without external air resistance. 2.2 Exclusions. 2.2.1 This standard does not apply to Evaporative Condensers designed primarily for installation within the machinery compartment of a sel
10、f-contained product or on a factory-assembled condensing unit. 2.2.2 This standard does not apply to Remote Mechanical-Draft Air-Cooled Refrigerant Condensers as covered by AHRI Standard 460. Section 3. Definitions Definitions. All terms in this document will follow the standard industry definitions
11、 in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined in this section. 3.1 Entering Air Wet-Bulb Temperature. The average wet-bulb temperature of the air entering the condenser assembly, F. 3.2 Halocarbon. A hydrocarbon der
12、ivative containing one or more of the halogens bromine, chlorine, or fluorine; hydrogen also may be present. 3.3 Net Refrigeration Effect. The rate of total heat absorption by the Refrigerant, at stated evaporator conditions, of the complete refrigeration system. This effect is equal to the product
13、of the refrigerant mass flow rate through the system and the enthalpy difference between the refrigerant vapor leaving the evaporator and the refrigerant liquid entering the liquid control device of the evaporator, Btu/h. 3.4 Published Rating. A statement of assigned values of those performance char
14、acteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown
15、on the unit or published in specifications, advertising or other literature, including computer software and computer-generated reports, controlled by the manufacturer, at stated Rating Conditions. 3.4.1 Application Rating. A rating based on tests performed at application rating conditions (other th
16、an Standard Rating Conditions). 3.4.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. AHRI STANDARD 490 (I-P)-2011 2 3.5 Rating Conditions. Any set of operating conditions under which a single level of performance results, and which causes only that level of perform
17、ance to occur. 3.5.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.6 Refrigerant. Fluid used for heat transfer in a refrigerating system which absorbs heat at a low temperature and low pressure of the fluid and transfers heat at a hi
18、gher temperature and a higher pressure of the fluid, usually involving changes of state of the the fluid. 3.7 Remote Mechanical-Draft Evaporatively-Cooled Refrigerant Condenser (Evaporative Condenser). A factory-made encased unit for connection to a refrigerant piping system. The unit shall include
19、means for mechanical air circulation, water distribution and heat transfer surface by which heat is transferred from Refrigerant to water and air. The purpose of this unit is to condense refrigerant vapor by rejecting heat to water and air which are circulated over its heat transfer surface, thereby
20、 causing evaporation of the water and an increase in the enthalpy of the air. 3.8 Saturated Condensing Temperature (Condensing Temperature). For single component and Azeotropic Refrigerants, the saturation temperature corresponding to the refrigerant pressure at the condenser entrance. For Zeotropic
21、 Refrigerants, the arithmetic average of the Dew Point and Bubble Point corresponding to the Refrigerant pressure at the condenser entrance, F. 3.8.1 Azeotropic Refrigerant. Blend of two or more component Refrigerants whose equilibrium vapor-phase and liquid-phase compositions are the same at a give
22、n pressure. 3.8.2 Bubble Point. The Refrigerant temperature at which bubbles begin to appear in a saturated liquid. 3.8.3 Dew Point. The Refrigerant temperature at which moisture begins to form. 3.8.4 Zeotropic Refrigerant. Blend of two or more component Refrigerants whose equilibrium vapor-phase an
23、d liquid-phase compositions are different at a given temperature. 3.9 Shall or Should. Shall or Should shall be interpreted as follows: 3.9.1 Shall. Where shall or shall not is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.9.2 Should. Shoul
24、d is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.10 Total Heat Rejection Effect (Capacity). The rate of total heat removal from the Refrigerant. This effect is equal to the product of the mass flow rate and enthalpy difference between the refrigera
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI490IP2011PERFORMANCERATINGOFREMOTEMECHANICALDRAFTEVAPORATIVELYCOOLEDREFRIGERANTCONDENSERSPDF

链接地址:http://www.mydoc123.com/p-422539.html