AHRI 440-2008 Performance Rating of Room Fan-Coils.pdf
《AHRI 440-2008 Performance Rating of Room Fan-Coils.pdf》由会员分享,可在线阅读,更多相关《AHRI 440-2008 Performance Rating of Room Fan-Coils.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 2008 Standard for Performance Rating of Room Fan-Coils ANSI/AHRI Standard 440 (Formerly ARI Standard 440) Price $10.00 (M) $20.00 (NM) Copyright 2008, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office AHRI CERTIFICATION
2、PROGRAM PROVISIONS Scope of the Certification Program The certification program includes Room Fan-Coils as defined in Section 3, having air-delivery capacities of 1500 cfm 0.7080 m3/s or less. Room Fan-Coils employing Volatile Refrigerant Coils or steam coils, central-station air-handling units as d
3、efined in AHRI Standard 430, and unit ventilators as defined in ARI Standard 840 are not included. Certified Ratings The following certification program ratings shall be verified by test at the Standard Rating Conditions for Cooling Capacity (Section 6.3.1), and for power input (Section 6.3.4): 1. T
4、otal Cooling Capacity, Btu/h W 2. Sensible Cooling Capacity, Btu/h W 3. Power Input, W W Conformance to the requirements of the insulation efficiency test and the low voltage test (Section 8) shall also be verified by test. Note: This standard supersedes ARI Standard 440-2005. IMPORTANT SAFETY DISCL
5、AIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, instal
6、led and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify o
7、r guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose .1 Section 2. Scope 1 Section 3. Definitions 1 Section 4. Classifications .3 Section 5. Test Requirements 3 Section 6. Rating Requirements 3
8、Section 7. Minimum Data Requirements for Published Ratings .5 Section 8. Operating Requirements .6 Section 9. Marking and Nameplate Data .6 Section 10. Conformance Conditions 6 TABLES Table 1. Heating Rating Conditions .4 APPENDICES Appendix A. References - Normative 7 Appendix B. References - Infor
9、mative 7 ANSI/AHRI STANDARD 440-2008 1 PERFORMANCE RATING OF ROOM FAN-COILS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to provide for Room Fan-Coils: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; operating
10、requirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as techn
11、ology advances. Section 2. Scope 2.1 Scope. This standard applies to Room Fan-Coils, defined in Section 3, having air-delivery capacities of 1500 cfm 0.7080 m3/s or less. 2.2 Exclusions. 2.2.1 This standard does not apply to central-station air-handling units as defined in ANSI/AHRI Standard 430. 2.
12、2.2. This standard does not apply to unit ventilator units as defined in AHRI Standard 840. 2.2.3 This standard does not apply to Room Fan-Coils employing: a. Volatile Refrigerant Coils b. Steam coils Section 3. Definitions All terms in this document shall follow the standard industry definitions in
13、 the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined in this section. 3.1 Capacity. 3.1.1 Cooling Capacity. The capacity associated with the change in air enthalpy which includes both the Latent and Sensible Capacities expres
14、sed in Btu/hW. 3.1.1.1 Latent Capacity. Capacity associated with a change in humidity ratio. 3.1.1.2 Sensible Capacity. Capacity associated with a change in dry-bulb temperature. 3.1.2 Heating Capacity. The capacity associated with the change in dry-bulb temperature expressed in Btu/hW. 3.2 Fan. A d
15、evice for moving air which utilizes a power-driven rotating impeller. 3.3 Forced-Air Circulation. Air circulation caused by a difference in pressure produced by a fan. 3.4 Grille. Lattice or grating covering the delivery or intake opening of an air passage. 3.5 Non-Volatile Refrigerant Coil. A coil
16、in which the cooling fluid (usually water) remains in the liquid state during its passage through the coil. ANSI/AHRI STANDARD 440-2008_ 2 3.6 Published Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to f
17、it its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature con
18、trolled by the manufacturer, at stated Rating Conditions. 3.6.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.6.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.7 Rating Condition
19、s. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.7.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.8 Room Fan-Coil (cooling, heating, or
20、cooling and heating). A factory-made assembly which provides the functions of cooling, heating, or cooling and heating, but which does not include the source of cooling or heating. This device is designed for free-delivery of air into a room, but may be applied with minimal duct work having a static
21、 resistance generally not exceeding 0.25 in H2O 0.062 kPa. These devices may be designed for furred-in application, or with an enclosure for application within the conditioned space. 3.8.1 Free Delivery Units. Free Delivery Units are Room Fan-Coils furnished with both integral filters and grilles on
22、 the unit. 3.8.2 Furred-in Units. Furred-in Units are Room Fan-Coils intended to be installed above a ceiling, within a side wall, or with a discharge grille. It may or may not have provisions for a filter. 3.9 Room Fan-Coil Motors. 3.9.1 Shaded Pole Motor. Single phase AC motor with offset start wi
23、nding and no capacitor. 3.9.2 PSC Motor. Single phase AC motor with offset start winding with capacitor. 3.9.3 EC Motor. AC electrically commutated permanent magnet DC motor. 3.10 “Shall“ or “Should,“ “Shall“ or “should“ shall be interpreted as follows: 3.10.1 Shall. Where “shall“ or “shall not“ is
24、used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.10.2 Should. “Should“ is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.11 Standard Air. Air weighing 0.075 lb/ft31.2 kg/m3 which approximates dr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI4402008PERFORMANCERATINGOFROOMFANCOILSPDF

链接地址:http://www.mydoc123.com/p-422534.html