AHRI 1361 SI-2016 Performance Rating of Computer and Data Processing Room Air Conditioners.pdf
《AHRI 1361 SI-2016 Performance Rating of Computer and Data Processing Room Air Conditioners.pdf》由会员分享,可在线阅读,更多相关《AHRI 1361 SI-2016 Performance Rating of Computer and Data Processing Room Air Conditioners.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、 2016 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners Approved by ANSI on July 8, 2016 ANSI/AHRI Standard 1361 (SI) Price $10.00 (M) $20.00 (NM) Copyright 2016, by Air-Conditioning Heating and Refrigeration Institute Printed in U.S.A. Registered United States Pa
2、tent and Trademark Office IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that prod
3、ucts be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/ guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and acc
4、epted industry practices. AHRI does not certify or guarantee that any tests conducted under the standards/guidelines will not be non-hazardous or free from risk. Note: This 2016 standard supersedes AHRI Standard 1361 (SI)-2013 with Addendum 1. For I-P ratings, see ANSI/AHRI Standard 1360 (I-P)-2016.
5、 AHRI CERTIFICATION PROGRAM PROVISIONS The current scope of the Datacom Cooling (DCOM) Certification Programs can be found on AHRI website www.ahrinet.org. The scope of the Certification Programs should not be confused with the scope of the standard, as the standard also includes ratings for product
6、s that are not covered by a certification program. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose . 1 Section 2. Scope 1 Section 3. Definitions . .1 Section 4. Classification . .4 Section 5. Test Requirements 5 Section 6. Rating Requirements 6 Section 7. Minimum Data Requirements for Published Ra
7、tings . 10 Section 8. Operating Requirements . 11 Section 9. Marking and Nameplate Data . 11 Section 10. Conformance 11 TABLES Table 1. Classification of Computer and Data Processing Room Air Conditioners . 4 Table 2. Standard Rating Conditions 7 Table 3. Minimum External Static Pressure for Up-Flow
8、 Ducted Discharge Units . 8 Table 4. Published Ratings . 10 FIGURES Figure 1. Up-flow Unit Test Duct 5 APPENDICES Appendix A. References Normative 12 Appendix B. References Informative 13 Appendix C. Standard Models - Normative . 14 Appendix D. Integrated Net Sensible COP - Informative 18 TABLES FOR
9、 APPENDICES Table C1. Standard Model Airflow Configurations 15 FIGURES FOR APPENDICES Table C1. Down-flow Unit 15 Table C2. Horizontal-flow Unit 15 Table C3. Up-flow Unit Ducted or Up-flow Unit Non-ducted 15 ANSI/AHRI STANDARD 1361 (SI)-2016 1 PERFORMANCE RATING OF COMPUTER AND DATA PROCESSING ROOM
10、AIR CONDITIONERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish definitions, classification, test requirements, rating requirements, minimum data requirements for Published Ratings, marking and nameplate data, and conformance conditions for Computer and Data Processing
11、Room Air Conditioners (CDPR), which provide cooling year round, and are designed to serve Data Centers and other Information Technology Equipment. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, users, and regulat
12、ors. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to floor mounted Computer and Data Processing Room Air Conditioners as defined in Section 3. 2.2 Exclusions. This standard does not apply to the
13、 following: 2.2.1 Rating and testing of individual assemblies, such as condensing units or coils, for separate use. 2.2.2 Unitary air-conditioners and unitary heat pumps as defined in ANSI/AHRI Standard 210/240 and AHRI Standard 340/360. 2.2.3 Variable refrigerant flow air conditioners and heat pump
14、s as defined in ANSI/AHRI Standard 1230. 2.2.4 Single package vertical packaged air conditioners rated using ANSI/AHRI Standard 390. 2.2.5 Packaged terminal air-conditioners rated using AHRI Standard 310/380. Section 3. Definitions All terms in this document will follow the standard industry definit
15、ions in the ASHRAE Wikipedia website (https:/www.ashrae.org/resources-publications/free-resources/ashrae-terminology) unless otherwise defined in this section. 3.1 Computer and Data Processing Room Air Conditioner (CDPR). A Computer and Data Processing Room Air Conditioner consists of one or more fa
16、ctory-made assemblies, which include a direct expansion evaporator or chilled water cooling coil, an air-moving device(s) and air-filtering device(s). The air conditioner may include a compressor, condenser, humidifier or reheating function. The functions of a CDPR, either alone or in combination wi
17、th a cooling plant, are to provide air filtration, air circulation, cooling, and humidity control (if the necessary options are included) These have two airflow configuration options: Direction and Connection. Each CDPR can be a combination of one Direction and two Connections (one Discharge from Un
18、it and one Return to Unit) 3.1.1 Direction. 3.1.1.1 Down-flow. Air passes vertically downward through cooling coil. Return air enters the top of the unit and discharge air leaves at the bottom of the unit. 3.1.1.2 Horizontal-flow. Air passes horizontally through cooling coil. Return air enters the r
19、ear of the unit and discharge air leaves at the front of the unit. ANSI/AHRI STANDARD 1361 (SI)-2016 2 3.1.1.3 Up-flow. Air passes vertically upward through cooling coil. Return air enters the bottom of the unit and discharge air leaves at the top of the unit. 3.1.2 Connections. 3.1.2.1 Discharge fr
20、om Unit. 3.1.2.1.1 Raised Floor Plenum Discharge. A unit which is sitting on and discharges air into an opening in a raised floor plenum. 3.1.2.1.2 Ducted Discharge. A unit which has and discharges air into field installed ductwork attached. 3.1.2.1.3 Free Air Discharge. A unit with a free air disch
21、arge which does not have field installed ductwork attached. This may include a factory installed integral grill or a field installed factory built plenum. 3.1.2.2 Return to Unit. 3.1.2.2.1 Raised Floor Plenum Return. A unit which is sitting on and returns air into an opening in a raised floor plenum
22、. 3.1.2.2.2 Ducted Return. A unit which has and returns air into a field installed ductwork attached. 3.1.2.2.3 Free Air Return. A unit with a free air return which does not have field installed ductwork attached. This may include a factory installed integral grill. 3.2 Computer Room Air Conditioner
23、 (CRAC). A CDPR that utilizes dedicated compressors and refrigerant cooling coils rather than chilled-water coils. 3.3 Computer Room Air Handler (CRAH). A CDPR that utilizes chilled-water coils for cooling rather than dedicated compressors. 3.4 Data Center. A building, room(s), or portions thereof,
24、serving an ITE load. 3.5 Floor Mounted Unit. A CDPR designed to be installed on a raised floor, floor stand, or a solid floor inside the building. 3.6 Fluid Economizer. An option available with a CRAC or CRAH system in which a cold fluid is circulated by a pump through an indoor heat exchanger to pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI1361SI2016PERFORMANCERATINGOFCOMPUTERANDDATAPROCESSINGROOMAIRCONDITIONERSPDF

链接地址:http://www.mydoc123.com/p-422506.html