1、 2014 Standard for Performance Rating of Heat Pump Pool Heaters AHRI Standard 1161 (SI) Price $10.00 (M) $20.00 (NM) Copyright 2014, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office Note: This standard supersedes ANSI/AH
2、RI Standard 1161-2009 (SI). For I-P ratings, see AHRI Standard 1160 (I-P) 2014. AHRI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program There currently is no AHRI certification program for Heat Pump Pool Heaters this Standard. IMPORTANT SAFETY DISCLAIMER AHRI does not set safety sta
3、ndards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance wit
4、h nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conduct
5、ed under its standards/guidelines will be non-hazardous or free from risk. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose.1 Section 2. Scope1 Section 3. Definitions1 Section 4. Classifications2 Section 5. Test Requirements.2 Section 6. Rating Requirements3 Section 7. Minimum Data Requirements for
6、 Published Ratings3 Section 8. Operating Requirements4 Section 9. Marking and Nameplate Data5 Section 10. Conformance Conditions.5 TABLES Table 1. Classifications of Heat Pump Pool Heaters.2 Table 2. Standard Rating Conditions.3 APPENDICES Appendix A. References Normative.6 Appendix B. References In
7、formative.6 AHRI STANDARD 1161(SI)-2011 1 PERFORMANCE RATING OF HEAT PUMP POOL HEATERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Heat Pump Pool Heaters: definitions; classifications; test requirements; rating requirements; minimum data requirements for Publishe
8、d Ratings; operating requirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review a
9、nd amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to the rating and testing of complete factory-made Heat Pump Pool Heaters as defined in Section 3. 2.1.1 Energy Source. This standard applies only to air-source, electrically driven, mechanical compression type sy
10、stems. 2.2 Exclusions. This standard does not apply to the following: 2.2.1 Individual assemblies 2.2.2 Unitary Air-Conditioners as defined in ANSI/AHRI Standard 210/240 with capacities less than 19,000 W 2.2.3 Unitary heat operated air-conditioning equipment 2.2.4 Water-Source Heat Pumps as defined
11、 in ANSI/AHRI/ASHRAE/ISO 13256-1 2.2.5 Commercial and Industrial Unitary Air Conditioning and Heat Pump Equipment with capacities of 19,000 W or greater as defined in ANSI/AHRI Standard 340/360 2.2.6 Single Package Vertical Air-Conditioners and Heat Pumps as defined in ANSI/AHRI Standard 390 2.2.7 P
12、ackage Terminal Air-Conditioners and Heat Pumps as defined in AHRI Standard 310/380 (CSA-C744) Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki) unless otherwise defined in this
13、 section. 3.1 Coefficient of Performance (COP). A ratio of the Heating Capacity in watts to the power input values in watts at any given set of Rating Conditions expressed in watts/watt. For heating COP, supplementary resistance heat shall be excluded. 3.1.1 Standard Coefficient of Performance. A ra
14、tio of the capacity to power input value obtained at Standard Rating Conditions. AHRI STANDARD 1161(SI)-2011 2 3.2 Heat Pump Pool Heater. A factory-made assembly, which contains the air moving device, compressor, refrigerant-to-water heat exchanger and air-to-refrigerant heat exchanger using ambient
15、 air as the heat source. Models may consist of more than one assembly to be used together for the purpose of cooling and heating air. Models with separated assemblies shall be designed to be used together, and the requirements of rating outlined in this standard are based upon the use of matched ass
16、emblies. 3.2.1 Heat Pump Pool Heaters shall provide the capability of heating pool water to achieve a controlled temperature, but may include the capabilities of pool water cooling, air-heating, air cooling, air-circulating, air-cleaning, or dehumidifying. 3.3 Heating Capacity. The capacity associat
17、ed with the change in water temperature, expressed in W. 3.4 Published Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal capacity and t
18、ype (identification) produced by the same manufacturer. As used herein, the term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.4.
19、1 Application Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.4.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.5 Rating Conditions. Any set of operating conditions under which a single level
20、of performance results and which causes only that level of performance to occur. 3.5.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.6 “Shall“ or “Should“. “Shall“ or “should“ shall be interpreted as follows: 3.6.1 Shall. Where “shal
21、l“ or “shall not“ is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.6.2 Should. “Should“ is used to indicate provisions which are not mandatory but which are desirable as good practice. Section 4. Classifications 4.1 Classifications. A Heat
22、Pump Pool Heater within the scope of this standard shall be classified by Functions as shown in Table 1. Section 5. Test Requirements 5.1 All Standard Ratings shall be verified by tests conducted in accordance with ANSI/ASHRAE Standard 146. Table 1. Classifications of Heat Pump Pool Heaters Types of
23、 Heat Pump Pool Heaters Designation Unit Type Pool Heating Only Pool Heating and Cooling Single Package SPPH-H SPPH-H/C Split System SSPH-H SSPH-H/C AHRI STANDARD 1161(SI)-2011 3 Section 6. Rating Requirements 6.1 Standard Rating. Standard Ratings shall be established by tests conducted at the Stand
24、ard Rating Conditions specified in Table 2. 6.1.1 Values for Standard Ratings. Standard Ratings relating to Heating Capacity shall be net values. If a circulating pump is within the unit and energized under normal operation, that electrical energy shall be included in the total power input to the un
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI1161SI2014PERFORMANCERATINGOFHEATPUMPPOOLHEATERSPDF

链接地址:http://www.mydoc123.com/p-422480.html