AHRI 1111 SI-2013 Performance Rating of Mechanical Transport Refrigeration Units.pdf
《AHRI 1111 SI-2013 Performance Rating of Mechanical Transport Refrigeration Units.pdf》由会员分享,可在线阅读,更多相关《AHRI 1111 SI-2013 Performance Rating of Mechanical Transport Refrigeration Units.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、 2013 Standard for Performance Rating of Mechanical Transport Refrigeration Units AHRI Standard 1111 (SI) Price $15.00 (M) $30.00 (NM) Copyright 2013, by Air-Conditioning Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY DISCL
2、AIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, instal
3、led and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify o
4、r guarantee that any tests conducted under the standards/guidelines will not be non-hazardous or free from risk. Note: For I-P ratings, see AHRI Standard 1110 (I-P)-2013. The AHRI Mechanical Transport Refrigeration (TR) Certification Program will certify only to AHRI Standard 1110 (I-P)-2013. AHRI S
5、tandard 1111 (SI)-2013 will not be used for the TR Certification Program. Price $15.00 (M) $30.00 (NM) Copyright 2007, by Air-Conditioning and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office TABLE OF CONTENTS SECTION PAGE Section 1. Purpose .1 Section 2
6、. Scope 1 Section 3. Definitions 1 Section 4. Test Requirements 3 Section 5. Rating Requirements 3 Section 6. Minimum Data Requirements for Published Ratings .4 Section 7. Operating Requirements .5 Section 8. Marking and Nameplate Data .5 Section 9. Conformance Conditions 5 TABLES Table 1. Standard
7、Rating Conditions 3 APPENDICES Appendix A. References - Normative 6 Appendix B. References - Informative 6 Appendix C. Calibrated-Box Method of Testing for Rating Mechanical Transport Refrigeration Units - Normative .7 Appendix D. Isothermal-Box Method of Testing for Rating Mechanical Transport Refr
8、igeration Units Normative 14 TABLES FOR APPENDICES Table C1. Calibrated-Box Test Tolerances .10 Table D1. Isothermal-Box Test Tolerances .18 FIGURES FOR APPENDICES Figure C1. Calibrated-Box Test Setup Schematic 8 Figure C2. Ambient Area Temperature Measuring Station Location Diagram 9 Figure C3. Cal
9、ibrated-Box Temperature Measuring Station Location Diagram 9 Figure D1. Isothermal-Box Test Setup Schematic .15 Figure D2. Surround Area Temperature Measuring Station Location Diagram .16 Figure D3. Isothermal-Box Temperature Measuring Station Location Diagram .16 AHRI STANDARD 1111-2013 (SI) 1 PERF
10、ORMANCE RATING OF MECHANICAL TRANSPORT REFRIGERATION UNITS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Mechanical Transport Refrigeration Units: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requir
11、ements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology
12、advances. Section 2. Scope 2.1 Scope. This standard applies to encased direct expansion vapor compression type Mechanical Transport Refrigeration Units with the following components: 2.1.1 Compressor 2.1.2 Air-cooled condenser 2.1.3 Refrigerant flow control(s) 2.1.4 Forced-Circulation Air-Cooler 2.1
13、.5 Base or frame 2.1.6 Prime Mover as described in the unit manufacturers literature 2.1.7 Power Train (coupling, power take-off, transmission, V-belt drive, etc.) connecting the unit to the Prime Mover Section 3. Definitions All terms in this document will follow the standard industry definitions i
14、n the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki) unless otherwise defined in this section. 3.1 Ambient Air. 3.1.1 The air surrounding the vehicle served by the Mechanical Transport Refrigeration Unit. 3.1.2 The air in the test enclosure surrounding the Calibrated-Box, per
15、the calibrated-box method of testing. 3.1.3 The air surrounding the engine-condenser side of a Mechanical Transport Refrigeration Unit, per the isothermal-box method of testing. 3.2 Calorimeter. A test facility consisting of one or two rooms, which may have an annular space(s); each equipped with in
16、strumented reconditioning equipment. The output of this equipment is measured and controlled to counterbalance the Net Refrigerating Capacity of the Mechanical Transport Refrigeration Unit under test. 3.2.1 Calibrated-Box. A well-insulated enclosure, with a known heat transfer rate determined throug
17、h calibration, which is used for measuring the heat loss or gain between the enclosures interior temperature and ambient temperature. The area surrounding the entire exterior of the Calibrated-Box is maintained at the rated ambient air temperature. 3.2.2 Isothermal-Box. A well-insulated enclosure, w
18、ith a known heat transfer rate determined through calibration, which is used for measuring the heat loss or gain between the enclosures interior temperature and ambient temperature. The area surrounding the Isothermal-Box is divided into a Surround Area and an ambient space. The Surround Area is mai
19、ntained at the rated return air temperature to the Forced-Circulation Air-Cooler, while the ambient space is maintained at the rated ambient air temperature. AHRI STANDARD 1111-2012(SI) 2 3.3 Forced-Circulation Air-Cooler. A factory-made assembly including means for forcing air circulation and compo
20、nents where heat is transferred from air to refrigerant. The purpose of this unit is to transfer heat from a refrigerated space, through the medium of air, to the refrigerant. 3.4 High-Temperature Service. Service requiring the maintenance of air temperature at a value of -4.0C or above in the refri
21、gerated compartment of the vehicle typically transporting non-frozen product. 3.5 Low-Temperature Service. Service requiring the maintenance of air temperature at a value below -4.0C in the refrigerated compartment of the vehicle typically transporting frozen product. 3.6 Mechanical Transport Refrig
22、eration Unit. A combination of one or more of the following factory-made assemblies: 3.6.1 A compressor, drive, and condenser combination 3.6.2 A Forced-Circulation Air-Cooler 3.6.3 All necessary refrigerant lines and electrical wiring 3.6.4 Means whereby the unit can be suitably mounted and install
23、ed on a vehicle which it is intended to serve Where such equipment is used in more than one assembly, the individual assemblies are designed to be used together, and the requirements of rating outlined in this standard are based on the use of matched assemblies. 3.7 Net Refrigerating Capacity. The r
24、ate of heat transferred from the air in the refrigerated space to the refrigerant circulated through the Forced-Circulation Air-Cooler, less heat added by the fan and drive, and other sources, in operation under specified conditions. It is the net refrigerating effect available for useful cooling. 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI1111SI2013PERFORMANCERATINGOFMECHANICALTRANSPORTREFRIGERATIONUNITSPDF

链接地址:http://www.mydoc123.com/p-422476.html