AGA REPORT 7-2006 Measurement of Natural Gas by Turbine Meters (2006) (XQ0601)《用汽轮计测量天然气(2006)XQ0601》.pdf
《AGA REPORT 7-2006 Measurement of Natural Gas by Turbine Meters (2006) (XQ0601)《用汽轮计测量天然气(2006)XQ0601》.pdf》由会员分享,可在线阅读,更多相关《AGA REPORT 7-2006 Measurement of Natural Gas by Turbine Meters (2006) (XQ0601)《用汽轮计测量天然气(2006)XQ0601》.pdf(77页珍藏版)》请在麦多课文档分享上搜索。
1、 AGA Report No. 7 Measurement of Natural Gas by Turbine Meters Revised February 2006 Prepared by Transmission Measurement Committee Copyright 2006 American Gas Association 400 North Capitol Street, NW, 4th Floor, Washington, DC 20001, U.S.A. Phone: (202) 824-7000 Fax: (202) 824-7082 Web: www.aga.org
2、 Catalog # XQ0601 . . iiDISCLAIMER AND COPYRIGHT The American Gas Associations (AGA) Operating Section provides a forum for industry experts to bring collective knowledge together to improve the state of the art in the areas of operating, engineering and technological aspects of producing, gathering
3、, transporting, storing, distributing, measuring and utilizing natural gas. Through its publications, of which this is one, the AGA provides for the exchange of information within the gas industry and scientific, trade and governmental organizations. Each publication is prepared or sponsored by an A
4、GA Operating Section technical committee. While AGA may administer the process, neither the AGA nor the technical committee independently tests, evaluates, or verifies the accuracy of any information or the soundness of any judgments contained therein. The AGA disclaims liability for any personal in
5、jury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on AGA publications. The AGA makes no guaranty or warranty as to the accuracy and completeness of any informa
6、tion published therein. The information contained therein is provided on an “as is” basis and the AGA makes no representations or warranties including any express or implied warranty of merchantability or fitness for a particular purpose, In issuing and making this document available, the AGA is not
7、 undertaking to render professional or other services for or on behalf of any person or entity. Nor is the AGA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advi
8、ce of a competent professional in determining the exercise of reasonable care in any given circumstances. The AGA has no power, nor does it undertake, to police or enforce compliance with the contents of this document. Nor does the AGA list, certify, test, or inspect products, designs, or installati
9、ons for compliance with this document. Any certification or other statement of compliance is solely the responsibility of the certifier or maker of the statement. The AGA does not take any position with respect to the validity of any patent rights asserted in connection with any items which are ment
10、ioned in or are the subject of AGA publications, and the AGA disclaims liability for the infringement of any patent resulting from the use of or reliance on its publications. Users of these publications are expressly advised that determination of the validity of any such patent rights, and the risk
11、of infringement of such rights, is entirely their own responsibility. Users of this publication should consult applicable federal, state, and local laws and regulations. The AGA does not, through its publications intend to urge action that is not in compliance with applicable laws, and its publicati
12、ons may not be construed as doing so. This report is the cumulative result of years of experience of many individuals and organizations acquainted with the measurement of natural gas. However, changes to this report may become necessary from time to time. If changes in this report are believed appro
13、priate by any manufacturer, individual or organization, such suggested changes should be communicated to AGA by completing the last page of this report titled, “Form for Suggestion to Change AGA Report No. 7, Measurement of Natural Gas by Turbine Meters“ and sending it to: Operations all documents s
14、hall be dated: a) A description of the meter, giving technical characteristics and principle of operation. b) A perspective drawing or photograph of the meter c) A list of parts with a description of their constituent materials d) A dimensional drawing e) A drawing showing locations of seals f) A dr
15、awing of the data plate or badge, showing arrangement of inscriptions g) Instructions for installation, operation, and periodic maintenance h) A general description of operation i) A description of available mechanical outputs and electronic output signals, and any adjustment mechanisms j) A descrip
16、tion of available electronic interfaces, wiring points and essential characteristics k) Documentation of compliance with applicable safety codes and regulations l) Test report of meter performance 95. Performance Requirements 5.1 General Performance Tolerances The manufacturer shall specify flow rat
17、e limits for Qmin, Qtand Qmaxfor each meter design and size. Meter performance at atmospheric pressure shall be within the following tolerances (see also Figure 1) after calibration. Repeatability: 0.2% from Qminto Qmax, Maximum peak-to-peak error: 1.0% above Qt, Maximum error: 1.0% from Qtto Qmax,
18、and, 1.5% from Qminto Qt, Transition flow rate: Qtnot greater than 0.2 Qmax. Note 1. The tolerances apply after adjustment of the change gears (if any) and/or setting of K-factors and application of the final meter factor. Note 2. The tolerances apply after any corrections performed within the meter
19、 itself but prior to the application of any linearization algorithms by equipment auxiliary to the meter. Note 3. These tolerances are applicable at atmospheric pressure. As operating gas pressure increases, the performance of the turbine meter can be expected to improve dramatically, with smaller v
20、alues for repeatability and maximum peak-to-peak error, provided the meter is calibrated for the intended operating conditions. Qt 0.2 QmaxQminFlow rate (Qi) Maximum peak-to-peak error 1.0% (Qi Qt) Repeatability +/-0.2% Percent error-1.75 -1.50 -1.25 -1.00 -0.75 -0.50 -0.25 0.00 0.25 0.50 0.75 1.00
21、1.25 1.50 1.75 Figure 1. Turbine Meter Tolerances at Atmospheric Pressure 105.2 Temperature and Gas Composition Influences The turbine meter shall meet the above performance requirements over the full operating range of temperature and gas composition. 5.3 Pressure Influences Research on the effects
22、 of pressure on turbine meter performance was conducted in 2002 and 2003, and the results published in Reference 3. To minimize error, turbine meters should be calibrated for the applicable operating conditions. Guidance on calibration requirements is provided in Section 6. 5.4 Meter Body Interchang
23、eability Meters with interchangeable measurement cartridges are designed so that the measurement cartridge can be removed from the meter body without removing the body from the installation. This design facilitates in situ inspection and replacement or upgrading of a cartridge. The construction of a
24、 meter with an interchangeable measurement cartridge shall be such that the performance characteristics specified in Section 5.1 are maintained after installation of the cartridge in other meter bodies of the same manufacturer, size and model, or after repeated removal and installation of the measur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AGAREPORT72006MEASUREMENTOFNATURALGASBYTURBINEMETERS2006XQ0601 汽轮 测量 天然气 2006 XQ0601PDF

链接地址:http://www.mydoc123.com/p-421947.html