AECMA TR 4647-2008 Aerospace series Termination procedure for EN 4639 optical contact Edition 1《航空航天系列.EN 4639标准光学接触用终止程序.版本1》.pdf
《AECMA TR 4647-2008 Aerospace series Termination procedure for EN 4639 optical contact Edition 1《航空航天系列.EN 4639标准光学接触用终止程序.版本1》.pdf》由会员分享,可在线阅读,更多相关《AECMA TR 4647-2008 Aerospace series Termination procedure for EN 4639 optical contact Edition 1《航空航天系列.EN 4639标准光学接触用终止程序.版本1》.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、ASD Technical Report Rapport Technique ASD ASD Fachbericht TR 4647 Edition 1 December 2008 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 763 3565 - www.asd-stan.orgICS: Descripto
2、rs: ENGLISH VERSION Aerospace series Termination procedure for EN 4639 optical contact Srie arospatiale Procdure de cblage pour contact optique EN 4639 Luft- und Raumfahrt Montageanleitung, fr Kontakte nach EN 4639 This Technical Report was drawn up by the Electrical Domain of ASD-STAN. The reason w
3、hich led to the publication of the document as a Technical Report is explained in the foreword. Edition approved for publication 31 December 2008 Electrical Domain Copyright 2008 by ASD-STAN Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permi
4、tted without license from IHS-,-,-Page 2 TR 4647:12-08 Contents Page Foreword2 1 EN 4639-10* contacts terminus assembly.3 2 Normative references 3 3 Safety summary .4 4 Termini contact procedure .4 4.1 EN-4639-101 termini contact procedure4 4.2 EN-4639-102 termini contact procedure.14 5 Fibre cleave
5、 . 24 6 Standard polish (multimode fibre) 25 6.1 General. 25 6.2 Coarse polishing (manual). 25 6.3 Fine polishing automatic . 26 7 Quality check. 26 7.1 Visual examination . 26 7.2 Interferometer control 29 8 Installation of the terminus into a multipin connector 29 Foreword The main task of ASD-STA
6、N Technical Committees is to prepare EN Standards, in exceptional circumstances however, the publication of Technical Report of one of the following types may be proposed: Type 1, the subject is still under technical development requiring wider exposure; Type 2, a Technical Committee has collected d
7、ata of a different kind from that which is normally published as a European Standard. The Electrical Domain decided to publish this document in the form of a Technical Report of type 2 in order to facilitate the updating of this document. Copyright ASD-STAN Provided by IHS under license with AECMA N
8、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 3 TR 4647:12-08 1 EN 4639-10* contacts terminus assembly This termination process defines the stages to reach the minimum qualification requirements for the EN 4639-101 terminus onto tight structure simplex fibre
9、optic cable and the EN 4639-102 terminus onto semi-loose structure simplex fibre optic cable using Epo-Tek 353ND epoxy adhesive in accordance with EN 4639-001. Other procedure could be applied if they conform to the minimum qualification requirements and with common agreement between manufacturers a
10、nd user. NOTE Two types of termini are described in the following termination processes. It is critical to use the proper termini with the correct type of fibre optic cable: EN 4641-100 cable (2 mm max. tight structure) must use the EN 4639-101 termini. EN 4641-102 cable (2 mm max. semi-loose struct
11、ure) must use the EN 4639-102 termini. CAUTION Training and qualification personnel terminating fibre optic contacts are mandatory. Throughout the termination process, cleanliness is critical to obtain a high optical quality contact. Make sure that the hands and work area are as clean as possible to
12、 minimise the intake of dirt into the contact parts. NOTE Verify that the epoxy adhesive shelf life has not expired. Do not use epoxy adhesive with an expiration date that has passed. 2 Normative references The following referenced documents are indispensable for the application of this document. Fo
13、r dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 4639-001, Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 diameter ferrule, with removable alignment sleeve
14、holder Part 001: Technical specification. EN 4639-101, Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 diameter ferrule, with removable alignment sleeve holder Part 101: Optical contact for cable EN 4641-100 Operating temperature between 65 C and 152 C Product standard
15、. EN 4639-102, Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 diameter ferrule, with removable alignment sleeve holder Part 102: Optical contact for cable EN 4641-102 Operating temperature between 55 C and 100 C Product standard. EN 4641-100, Aerospace series Cables,
16、optical 125 m diameter cladding Part 100: Tight structure 62,5/125 m GI fibre 1,8 mm outside diameter Product standard. 1)EN 4641-102, Aerospace series Cables, optical 125 m diameter cladding Part 102: Semi-loose 62,5/125 m GI fibre nominal 1,8 mm outside diameter Product standard. 1) In preparation
17、 at the date of publication of this standard. Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 4 TR 4647:12-08 3 Safety summary The following safety precautions shall be observed: a) Safety glasses sha
18、ll be worn at all times when handling bare fibres or dispensing epoxy adhesive. b) To reduce the chance of skin contamination wear suitable disposable gloves i.e. surgical latex gloves. c) Do not touch the ends of the fibre as they may puncture the skin. Wash the hands after handling bare fibre. d)
19、Avoid skin contact with epoxy adhesives. e) Never look directly into the end of a fibre, always look indirectly at the fibre end after verifying that the fibre is not emitting energy or use a microscope with integrated camera. 4 Termini contact procedure 4.1 EN-4639-101 termini contact procedure 4.1
20、.1 Cable and fibre preparation Step 1 Before termination, clean minimum of 10 cm of the outer jacket of cable end with a suitable cleaning solution (for example. Isopropyl Alcohol (IPA) impregnated wipes, or a lint free cloth dampened with the cleaning solution). Step 2 Install the cable marker slee
21、ve and supplied crimp sleeve over the simplex cable (single fibre cable). Ensure that the crimp sleeve is installed onto the cable rib side first. Slide the crimp sleeve back from the end of the simplex cable. See Figure 1. Key 1 Cable marker sleeve 2 Introduction direction 3 Simplex cable 4 Crimpin
22、g sleeve 5 Crimping sleeve ribs Figure 1 Installing crimp sleeve NOTE For items 3 to 6 refer to Figure 2 for dimensional information. Introduction direction3 4521 Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IH
23、S-,-,-Page 5 TR 4647:12-08 Step 3 Remove the cable jackets back to 23,5 mm using the cable stripper and cut the aramid yarn using the strength member shears so that it is even with the cable jacket. NOTE The optimum way to remove the cable jackets is to ring cut the jacket with the cable stripper an
24、d pull the jacket off by hand. Pushing off the simplex cable jacket with a tightly held simplex cable stripper can lead to fibre breakage. Step 4 Remove the simplex cable jacket back to 3 mm from outer jacket using the cable stripper. This step will expose the aramid yarn to the appropriate length.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMATR46472008AEROSPACESERIESTERMINATIONPROCEDUREFOREN4639OPTICALCONTACTEDITION1 航空航天 系列 EN4639 标准 光学

链接地址:http://www.mydoc123.com/p-421804.html