AECMA PREN 4611-007-2004 Aerospace series Cables electrical for general purpose single and multicore assembly XLETFE Family Part 007 Nickel plated copper Operating temperatures bet.pdf
《AECMA PREN 4611-007-2004 Aerospace series Cables electrical for general purpose single and multicore assembly XLETFE Family Part 007 Nickel plated copper Operating temperatures bet.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 4611-007-2004 Aerospace series Cables electrical for general purpose single and multicore assembly XLETFE Family Part 007 Nickel plated copper Operating temperatures bet.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM Edition approved for publication prEN 461 1-007 Edition P 1 July 2004 Comments should be sent within six months Electrical Domain ICs: Descriptors: ENGLISH VERSION Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Fam
2、ily Part 007: Nickel plated copper Operating temperatures, between - 65 OC and 150 OC Dual extruded wall for open applications UV laser printable Product standard Srie arospatiale Cbles, lectriques, dusage gnral, mono et multiconducteurs Famille XLETFE Partie 007 : Cuivre nickel Tempratures de fonct
3、ionnement comprises entre - 65 OC et 150 OC Fil double isol pour applications externes Marquable au laser UV Norme de produit Luft- und Raumfahrt Ein- und mehradrige elektrische Leitungen fr allgemeine Vewendung XLETFE Familie Teil 007: Kupfer vernickelt Doppelt extrudierte Isolierung fr externe Ver
4、wendung UV-Laser bedruckbar Produktnorm Betriebstemperaturen zwischen - 65 OC und 150 OC This “Aerospace Series“ frestandard has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Ae
5、rospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this frestandard, the technical content shall not be changed to an extent that interchangeabilify is affected, physically or functionally, without re-
6、identification of the standard. After examination and review by users and formal agreement of AECMA-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national membe
7、rs have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. 31 July 2004 after the date of publication to AECMA-STAN I I Copytight 2004 O by AECMA-STA1 Copyright Association Europeene des Con
8、structeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 2 prEN 461 1-007:2004 Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANS Electrical Domain . After inqu
9、iries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA- STANS General Process Manual. this standard has received approval for Publication . Contents Page 1 Scope 3 2 Normative references . 3 3 4 4.1 4.2 4.3 4.4 5 6 7 8 9 10 Definitions and symbols . Materials and con
10、struction Materials Construction . Number of cores . Colour coding of cores . Required characteristics . Quality assurance . Designation Identification and marking Packaging, labelling and delivery lengths Technical specification 3 4 4 4 5 5 5 9 9 9 9 9 Copyright Association Europeene des Constructe
11、urs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 3 prEN 461 1-007:2004 1 Scope This standard specifies the characteristics of UV laser printable, nickel plated copper conductor, electrical cables
12、 Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use in the on-board electrical systems of aircraft at operating temperatures between - 65 OC and 150 OC, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 O00 Hz. These cables are suitable for airf
13、rame use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence. 2 Normative references This European Standard incorporates by dated or undated reference provisions from other publications. These
14、 normative references are cited at the appropriate places in the text and the publications are listed hereafter. Dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated ref
15、erences the latest edition of the publication referred to applies. EN 2083, EN 2084, EN 2235 EN 3475-loo*, EN 461 1-002, EN 9133, Aerospace series - Copper or copper alloy conductors for electrical cables - Product standard Aerospace series - Cables, electric, single-core, general purpose, with cond
16、uctors in copper or copper alloy - Technical specification ) Aerospace series - Single and multicore electrical cables, screened and jacketed ) Aerospace series - Cables, electrical, aircraft use - Test methods - Part 700: General Aerospace series - Cables, electrical, for general purpose, single an
17、d multicore assembly - XLETFE Family- Part 002: General ) Aerospace series - Quality management systems - Qualifiation Procedure for Aerospace Standard Parts ) 3 Definitions and symbols See EN 3475-100. * And all its parts 1) Published as AECMA Prestandard at the date of publication of this standard
18、 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 4 prEN 461 1-007:2004 Maximum external diameter mm 4 Materials and construction 4.1 Materials Condu
19、ctor The cable conductors shall be made of nickel plated copper according to EN 461 1-002 and EN 2083 code D. Insulation for conductor all size codes - first insulator extruded XLETFE, coloured blue or a contrasting colour if the second is blue; - second insulator extruded XLETFE. For single core, i
20、t shall be possible to mark the outer insulation by UV laser printing. Mass kg/km max. 4.2 Construction See EN 461 1-002, Table 1 and Table 2. Table 1 - Single core cables Code for nominal section O01 002 004 006 o1 o o1 2 020 030 050 O90 140 220 340 530 680 Nominal section mm2 I AWG a 0,15 0,25 0,6
21、 1 132 2 3 5 9 14 22 34 53 68 0,4 26 24 22 20 18 16 14 12 10 8 6 4 3 1 O Linear resistance at 20 OC Q/km max. 160,O 114,O 60,O 33,2 21,l 15,3 10,9 63 432 2,28 1,43 0,90 0,58 0,37 0,29 1 ,O7 1,19 1,37 1,58 1,85 2,13 2,44 2,95 3,61 5,16 6,38 8,13 10,67 13,36 15,20 2,52 3,49 4,90 7,55 10,80 15,70 20,63
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便