AECMA PREN 3475-307-2009 Aerospace series Cables electrical aircraft use Test methods Part 307 Corona extinction voltage Edition P 2《航空航天系列.航空用电缆.测试方法.第307部分 电晕熄灭电压.版本P2》.pdf
《AECMA PREN 3475-307-2009 Aerospace series Cables electrical aircraft use Test methods Part 307 Corona extinction voltage Edition P 2《航空航天系列.航空用电缆.测试方法.第307部分 电晕熄灭电压.版本P2》.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 3475-307-2009 Aerospace series Cables electrical aircraft use Test methods Part 307 Corona extinction voltage Edition P 2《航空航天系列.航空用电缆.测试方法.第307部分 电晕熄灭电压.版本P2》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、ASD STANDARD NORME ASD ASD NORM prEN 3475-307 Edition P 2 June 2009 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 775 8131 - www.asd-stan.orgICS: 49.060 Supersedes edition P 1 of
2、 March 2002 and will supersede EN 3475-307:2005 Descriptors: ENGLISH VERSION Aerospace series Cables, electrical, aircraft use Test methods Part 307: Corona extinction voltage Srie arospatiale Cbles lectriques usage aronautique Mthodes dessais Partie 307 : Tension dextinction corona Luft- und Raumfa
3、hrt Elektrische Leitungen fr Luftfahrtverwendung Prfverfahren Teil 307: Corona-Aussetzspannung This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of t
4、he European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionall
5、y, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN na
6、tional members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 10 June 2009 Comments should be sent within six months after the date of publication t
7、o ASD-STAN Electrical Domain Copyright 2009 by ASD-STAN Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3475-307:20092 Contents Page Foreword2 Introduction .3 1 Scope 3 2 Normative references 3 3 Abbr
8、eviations and definitions 4 4 Applicability4 5 Apparatus .4 6 Methods 4 7 Procedure .7 8 Requirement.8 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD
9、-STANs General Process Manual, this standard has received approval for Publication. Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3475-307:2009 3 Introduction For an electrical cable, the presence o
10、f partial discharges effects at operating voltage may result in a significant reduction of service life. Some insulation materials are more susceptible to such discharge damage than others. Evidence of partial discharges during operation signifies for example: the insulation thickness is insufficien
11、t for the applied voltage; the quality of the insulation is inadequate possibly due to excessive size of internal cavities or voids; an overstress is present, resulting in a local reduction of the cable insulation properties. Significant parameters may influence PDIV and PDEV such as pressure, tempe
12、rature, humidity, previous electrification, rate of the voltage increase. Attention shall be given to installation conditions, for example excessive bending or surface wrinkling of insulation shall be avoided. Up to few tens of kHz frequency can be considered as non-significant parameter. 1 Scope Th
13、is test standard defines methods to cover the detection and measurement of partial discharge (corona) under an applied test voltage, including the determination of partial discharges (corona) inception and extinction voltages as the test voltage is raised and lowered, of electrical cables for aircra
14、ft use. It shall be used together with EN 3475-100. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including
15、 any amendments) applies. EN 2084, Aerospace series Cables, electric, single-core, general purpose, with conductors in copper or copper alloy Technical specification. EN 2235, Aerospace series Single and multicore electrical cables, screened and jacketed. EN 3475-100, Aerospace series Cables, electr
16、ical, aircraft use Test methods Part 100: General. EN 60270, High-voltage test techniques Partial discharge measurements. ASTM D 1868, Standard test method for detection and measurement of partial discharge (Corona) pulses in evaluation of insulation systems. 1)1) Published by: American Society for
17、Testing and Materials (ASTM), 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 USA. Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3475-307:20094 3 Terms and definitions For the p
18、urposes of this document, the following terms and definitions apply. 3.1 partial discharge inception voltage (PDIV) is the lowest voltage at which continuous partial discharges occur as the applied voltage is increased 3.2 partial discharge extinction voltage (PDEV) is the highest voltage at which p
19、artial discharges no longer occur as the applied voltage is decreased from the inception voltage described before More precise information on the partial discharge phenomenon, such as definition, can be found in ASTM D 1868-07 or in EN 60270. 4 Applicability This test method is suitable for coaxial
20、cables, high voltage cables and for thin wall insulated cables. Three methodologies are proposed to cover: coaxial cables (Method A), wires used in altitude (Method B) and wires in ambient conditions (Method C). 5 Apparatus The equipment shall be capable of detecting partial discharges of five picoc
21、oulombs or less. The detection equipment, cautions and measurement procedures shall be equivalent to those described in ASTM D 1868 or in EN 60270. The frequency of the test voltage shall be between 48 Hz to 62 Hz. 6 Methods 6.1 General Three methods are proposed according to specific needs. Unless
22、otherwise specified in the concerned product standard Method A applies. The minimum specimen length shall be chosen so that its capacitance is matched to the needs of the detecting equipment to permit observation of discharges of the level described in Clause 5. Use ASTM D 1868 for guidance to deter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMAPREN34753072009AEROSPACESERIESCABLESELECTRICALAIRCRAFTUSETESTMETHODSPART307CORONAEXTINCTIONVOLTAGEEDITIONP2

链接地址:http://www.mydoc123.com/p-420320.html