AASHTO TP 85-2010 Standard Method of Test for Apparent Viscosity of Hot-Poured Bituminous Crack Sealant Using Brookfield Rotational Viscometer RV Series Instrument.pdf
《AASHTO TP 85-2010 Standard Method of Test for Apparent Viscosity of Hot-Poured Bituminous Crack Sealant Using Brookfield Rotational Viscometer RV Series Instrument.pdf》由会员分享,可在线阅读,更多相关《AASHTO TP 85-2010 Standard Method of Test for Apparent Viscosity of Hot-Poured Bituminous Crack Sealant Using Brookfield Rotational Viscometer RV Series Instrument.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、TS-4e TP 85-1 AASHTO Standard Method of Test for Apparent Viscosity of Hot-Poured Bituminous Crack Sealant Using Brookfield Rotational Viscometer RV Series Instrument AASHTO Designation: TP 85-10 (2013) 1. SCOPE 1.1. This test method outlines the procedure for measuring the apparent viscosity of hot
2、-poured bituminous crack sealant at elevated temperature from 150 to 200C using a rotational viscometer. 1.2. The rotational viscometer is a rotating spindle-type viscometer that meets the requirements of T 316. This test method can be used for general specification and is especially convenient for
3、use in a field laboratory or a plant site. 1.3. This standard may involve hazardous material, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety
4、 and health practices and determine the application of regulatory limitations prior to use. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standard: T 316, Viscosity Determination of Asphalt Binder Using Rotational Viscometer 2.2. ASTM Standards: D 5167, Standard Practice for Melting of Hot-Applied Joint and C
5、rack Sealant and Filler for Evaluation E 1, Standard Specification for ASTM Liquid-in-Glass Thermometers E 220, Standard Test Method for Calibration of Thermocouples By Comparison Techniques 2.3. Sealant Consortium (SC) Standards:1 SC-1, Guidelines for Graded Bituminous Sealants SC-2, Test Method fo
6、r Measuring Apparent Viscosity of Hot-Poured Crack Sealant Using Brookfield Rotational Viscometer RV Series Instrument SC-3, Method for the Accelerated Aging of Bituminous Sealants SC-4, Sealant Flow and Deformation SC-5, Method to Measure Low-Temperature Sealant Flexural Creep Stiffness at Low Temp
7、erature by Bending Beam Rheometer SC-6, Method to Evaluate Sealant Extensibility at Low Temperature by Direct Tension Test SC-8, Blister Method to Predict the Adhesion of Bituminous Sealants 2013 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplicati
8、on is a violation of applicable law.TS-4e TP 85-2 AASHTO 3. TERMINOLOGY 3.1. hot-poured crack sealantshot-poured modified asphaltic materials used in pavement cracks and joints. 3.2. apparent viscositythe ratio of shear stress to shear rate for a liquid. This parameter is a measure of the resistance
9、 to flow of the liquid. The SI unit of viscosity is the Pascal second (Pas). 4. SUMMARY OF METHOD 4.1. Crack sealant material is homogenized according to ASTM D 5167, cut into cubes no larger than 5 mm by 5 mm and placed into standard containers. Apparent viscosity is measured utilizing the Brookfie
10、ld viscometer using Spindle #SC4-27. The spindle shall be attached to the rigid hook attachment and rotates at the speed of 60 rpm. The test shall be conducted at the manufacturers recommended installation temperature. 5. SIGNIFICANCE AND USE 5.1. This test is intended for bituminous sealants applie
11、d to roadway joints and cracks. 5.2. This procedure is designed to simulate the viscosity of crack sealants while pouring the sealant into the cracks. 5.3. Sealants must be homogenized (ASTM D 5167) before measuring the apparent viscosity by this method. 6. APPARATUS 6.1. Brookfield rotational visco
12、meter RV Series Instrument. 6.2. Brookfield ThermoselMaintaining a temperature ranging from 170 to 193C 1C. 6.3. Laboratory OvenAny laboratory standard oven capable of producing and maintaining a temperature ranging from 170 to 193C 1C. 6.4. Rigid hook attachment especially designed as an attachment
13、 in the Brookfield viscometer to measure hot-poured crack sealant viscosity. 6.5. Disposable aluminum containers or standard Brookfield containers. 6.6. The rotational viscometer contains sensors that monitor the applied torque and automatically display the calculated apparent viscosity. The keypad
14、on the instrument is used to enter the spindle number, zero the signal, and run the test at a selected speed. Torque and viscosity can be recorded manually, or an interface can be used to send the signal from the instrument to a personal computer. Optional software is also available that can be used
15、 to program preselected thermal profiles. This software is not needed for the specification test. However, the Thermosel must be used to control the temperature and thereby obtain acceptable reproducibility. 2013 by the American Association of State Highway and Transportation Officials.All rights re
16、served. Duplication is a violation of applicable law.TS-4e TP 85-3 AASHTO 7. HAZARDS 7.1. Standard laboratory caution should be used in handling hot sealant in accordance with ASTM D 5167, and when using the Brookfield Thermosel. Required safety procedures should be followed when chemical agents are
17、 used. 8. PREPARATION OF APPARATUS 8.1. The rotational viscometer must be leveled to function properly. A bubble-type level is normally located on top of the viscometer and is adjusted by using leveling screws located on the base. Preparing the device, leveling and aligning of the viscometer on the
18、stand, and setting the temperature of the Thermosel are explained in the operation instructions provided by the manufacturer. The detailed steps for testing are specified in T 316. 9. CALIBRATION AND STANDARDIZATION 9.1. Temperatures of the ovens should be calibrated in accordance with each users qu
19、ality assurance program. 9.2. Thermometer (temperature detector) should be calibrated every 6 months to ensure precision of 1C. Verify and calibrate in accordance with ASTM E 1 or ASTM E 220 as applicable. 9.3. The accuracy of the viscometer should be checked annually using a certified reference flu
20、id of known viscosity following the procedure recommended by the manufacturer. 10. PREPARATION OF SAMPLES AND TEST SPECIMENS 10.1. All apparent viscosity measurements must be performed on homogenized sealant. Sealant homogenization is conducted in accordance with the procedure presented in ASTM D 51
21、67. 10.2. Once homogenized, hot sealant should be cooled down to room temperature and stored for 24 h before usage. It is recommended that a can or plastic-lined box be used as a container during the cooldown period. The container must be of sufficient size so that the sealant depth is no greater th
22、an 100 mm to allow for rapid cooling. 10.3. Cut 10.5 g of the homogenized sealant into small cubes no larger than 5 mm by 5 mm, and place the cubes in aluminum chambers. Disposable chambers installed in the Thermosel shall be used. 11. PROCEDURE 11.1. Preheat the Thermosel to test temperature and, u
23、nless otherwise noted, use the temperature recommended by the manufacturer. 11.2. Place aluminum chamber containing sealant in the Thermosel. 11.3. Turn on the viscometer and zero it. 11.4. Allow 5 min for sealant to melt. 11.5. Assemble spindle #SC4-27 and attach the spindle to a rigid rod (see Not
24、e 1). 2013 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4e TP 85-4 AASHTO Note 1The current hook that is used for asphalt cement should not be applied to asphalt binder that contains rubber fillers, whi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOTP852010STANDARDMETHODOFTESTFORAPPARENTVISCOSITYOFHOTPOUREDBITUMINOUSCRACKSEALANTUSINGBROOKFIELDROTATIONALVISCOMETERRVSERIESINSTRUMENTPDF

链接地址:http://www.mydoc123.com/p-418418.html