AASHTO T 154-2018 Standard Method of Test for Time of Setting of Hydraulic Cement Paste by Gillmore Needles.pdf
《AASHTO T 154-2018 Standard Method of Test for Time of Setting of Hydraulic Cement Paste by Gillmore Needles.pdf》由会员分享,可在线阅读,更多相关《AASHTO T 154-2018 Standard Method of Test for Time of Setting of Hydraulic Cement Paste by Gillmore Needles.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Method of Test for Time of Setting of Hydraulic Cement Paste by Gillmore Needles AASHTO Designation: T 154-181Technical Section: 3a, Hydraulic Cement and Lime Release: Group 1 (April) ASTM Designation: C266-15 American Association of State Highway and Transportation Officials 444 North Capi
2、tol Street N.W., Suite 249 Washington, D.C. 20001 TS-3a T 154-1 AASHTO Standard Method of Test for Time of Setting of Hydraulic Cement Paste by Gillmore Needles AASHTO Designation: T 154-181Technical Section: 3a, Hydraulic Cement and Lime Release: Group 1 (April) ASTM Designation: C266-15 1. SCOPE 1
3、.1. This test method covers the determination of the time of setting of hydraulic cement paste by means of the Gillmore needles. 1.2. The values stated in inch-pound units are to be regarded as standard. The SI units, regarded as standard in ASTM C266, are provided for informational use only with re
4、gard to the original direction of mathematical conversion; as such, the inch-pound units are shown in parentheses. 1.3. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the re
5、sponsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Warning Fresh hydraulic cementitious mix tures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. 1
6、.4. The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 201, Mixing Rooms, Moist Cabinet
7、s, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes R 70, Use of Apparatus for the Determination of Length Change of Hardened Cement Paste, Mortar, and Concrete R 71, Sampling and Amount of Testing of Hydraulic Cement T 107M/T 107, Autoclave Expansion of Hy
8、draulic Cement T 129, Amount of Water Required for Normal Consistency of Hydraulic Cement Paste T 162, Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency 2018 by the American Association of State Highway and Transportation Officials. All rights reserved. Duplication is a
9、 violation of applicable law.TS-3a T 154-2 AASHTO 2.2. ASTM Standards: C219, Standard Terminology Relating to Hydraulic Cement C670, Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials C1005, Standard Specification for Reference Masses and Device
10、s for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements D1193, Standard Specification for Reagent Water 2.3. Other Standard: Azari, H. and R. Lutz. NCHRP Web-Only Document 140: Precision Estimates for AASHTO Test Methods T 186, T 154, and T 22, Determined Using CCRL Pr
11、oficiency Sample Data. National Cooperative Highway Research Program, Transportation Board of the National Academies, Washington, DC, 2009, 48 pp. http:/onlinepubs.trb.org/onlinepubs/nchrp/nchrp_w140.pdf 3. TERMINOLOGY 3.1. Refer to ASTM C219 for definitions of terms. 4. SUMMARY OF TEST METHOD 4.1.
12、Sufficient water is added to the cement that is being tested to produce a paste of normal consistency. A specimen is molded from this paste and is tested for time of setting by means of the Gillmore initial and final needles. The Initial Time of Setting is the time elapsed between initial contact of
13、 cement and water and the time when the Gillmore initial needle does not leave a complete circular impression in the paste surface. The Final Time of Setting is the time elapsed between initial contact of cement and water and the time when the Gillmore final needle does not leave a complete circular
14、 impression in the paste surface. 5. SIGNIFICANCE AND USE 5.1. The purpose of this test method is to establish whether a cement complies with a specification limit on Gillmore time of setting. 6. APPARATUS 6.1. Flat TrowelHaving a sharpened straight-edged steel blade 100 to 150 mm in length. The edg
15、es, when placed on a plane surface, shall not depart from straightness by more than 1 mm. 6.2. Mixer, Bowl, Paddle, and ScraperConforming to the requirements of T 162. 6.3. Glass Graduates200- or 250-mL capacity, conforming to the requirements of R 7 0. 6.4. Mass Determining DevicesConforming to the
16、 requirements of ASTM C1005. The devices for determining mass shall be evaluated for precision and accuracy at a total load of 1000 g. 6.5. Plane Nonabsorptive Plates102 5 mm2(4 0.125 in.2), of similar planeness, corrosivity, and absorptivity to that of glass (see T 129, Figure 1, item H). 6.6. Gill
17、more NeedlesConforming to the following requirements: 2018 by the American Association of State Highway and Transportation Officials. All rights reserved. Duplication is a violation of applicable law.TS-3a T 154-3 AASHTO 6.6.1. The Initial Time of Setting needle shall have a mass of 113.4 0.5 g (0.2
18、50 0.001 lb) and a tip diameter of 2.12 0.05 mm (0.084 0.002 in.). 6.6.2. The Final Time of Setting needle shall have a mass of 453.6 0.5 g (1.000 0.001 lb) and a tip diameter of 1.06 0.05 mm (0.042 0.002 in.). 6.6.3. The needle tips shall be cylindrical for a distance of 4.8 0.5 mm (0.189 0.020 in.
19、). The needle ends shall be plane and at right angles to the axis of the rod and shall be maintained in a clean condition. (See Note 1.) Note 1The Gillmore needles should preferably be mounted as shown in Figure 1(b). 6.7. Inspect and document Section 6 apparatus for conformance to the requirements
20、of this test method at least every 21/2years. 7. REAGENTS 7.1. Mixing WaterPotable water is satisfactory for routine tests. For all referee and cooperative tests, reagent water conforming to the requirements of ASTM D1193 for Type III or Type IV grade of reagent water shall be used. 8. SAMPLING 8.1.
21、 When the test is part of acceptance testing, sample the cement in accordance with R 71. 9. CONDITIONING 9.1. Maintain the temperature of the room, dry materials, paddle, bowl, and plane nonabsorptive plates at 23.0 3.0C (73.4 5.4F). Maintain the temperature of the mixing water at 23.0 2.0C (73.4 3.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便