1、Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe AASHTO Designation: M 206M/M 206-171Technical Section: 4a, Concrete Drainage Structures Release: Group 2 (June 2017) ASTM Designation: C506M-16b and C506-16b American Association of State Highway and Transportat
2、ion Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-4a M 206M/M 206-1 AASHTO Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe AASHTO Designation: M 206M/M 206-171Technical Section: 4a, Concrete Drainage Structures Release: Group 2
3、(June 2017) ASTM Designation C506M-16b and C506-16b 1. SCOPE 1.1. This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2. This specification is applicable for orders in either S
4、I units (M 206M) or in inch-pound units (M 206). SI units and inch-pound units are not necessarily equivalent. Inch-pound units are shown in brackets in the text for clarity, but they are the applicable values when the material is ordered to M 206. Note 1This specification is a manufacturing and pur
5、chase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends on the proper selection of the class of p
6、ipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. Owners of the reinforced concrete pipe specified herein are cautioned that they must correlate the field requirements with the class of pipe specified and provide inspection at the construc
7、tion site. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 6, Fine Aggregate for Hydraulic Cement Concrete M 31M/M 31, Deformed and Plain Carbon and Low-Alloy Steel Bars for Concrete Reinforcement M 32M/M 32, Steel Wire, Plain, for Concrete Reinforcement M 55M/M 55, Steel Welded Wire Reinforcement,
8、 Plain, for Concrete M 80, Coarse Aggregate for Hydraulic Cement Concrete M 85, Portland Cement M 154M/M 154, Air-Entraining Admixtures for Concrete M 157, Ready-Mixed Concrete M 194M/M 194, Chemical Admixtures for Concrete M 221M/M 221, Steel Welded Wire Reinforcement, Deformed, for Concrete M 225M
9、/M 225, Steel Wire, Deformed, for Concrete Reinforcement M 240M/M 240, Blended Hydraulic Cement 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 206M/M 206-2 AASHTO M 262, Concrete Pipe and Relate
10、d Products M 295, Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete M 302, Slag Cement for Use in Concrete and Mortars T 280, Concrete Pipe, Manhole Sections, or Tile 2.2. ASTM Standards: A36/A36M, Standard Specification for Carbon Structural Steel A706/A706M, Standard Specificat
11、ion for Deformed and Plain Low-Alloy Steel Bars for Concrete Reinforcement C309-03, Standard Specification for Liquid Membrane-Forming Compounds for Curing Concrete C1017/C1017M, Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete C1116/C1116M, Standard Specification
12、 for Fiber-Reinforced Concrete 3. TERMINOLOGY 3.1. DefinitionsFor definitions of terms relating to concrete pipe, see M 262. 4. CLASSIFICATION 4.1. Pipe manufactured according to this specification shall be of three classes identified as Class A-II, A-III, and A-IV. The strength requirements are pre
13、scribed in Table 1 for SI units or Table 2 for inch-pound units. 5. BASIS OF ACCEPTANCE 5.1. Unless otherwise designated by the owner at the time of or before placing an order, there are two separate and alternative bases of acceptance. Independent of the method of acceptance, the pipe shall be desi
14、gned to meet both the 0.3-mm 0.01-in. crack and ultimate strength requirements. 5.1.1. Acceptance on Basis of Plant Load Bearing Tests, Material Tests, and Inspection of Manufactured Pipe for Visual Defects and ImperfectionsAcceptability of the pipe in all diameters and classes produced in accordanc
15、e with Section 7.1 or Section 7.2 shall be determined by the results of the three-edge-bearing tests as defined in Section 11.3.1; by such material tests as are required in accordance with Sections 6.2, 6.3, 6.5, and 6.6; by an absorption test of the concrete from the wall of the pipe as required in
16、 11.9; and by visual inspection of the finished pipe to determine its conformance with the accepted design and its freedom from defects. 5.1.2. Acceptance on Basis of Material Tests and Inspection of the Complete ProductAcceptability of the pipe in all diameters and classes produced in accordance wi
17、th Section 7.1 or 7.2 shall be determined by the results of such material tests as are required in Sections 6.2, 6.3, 6.5, and 6.6; by crushing tests on concrete cores or cured concrete cylinders; by an absorption test of the concrete from the wall of the pipe for each mix design that is used on an
18、order; and by inspection of the finished pipe, including amount and placement of reinforcement, to determine its conformance with the accepted design and its freedom from defects. 5.1.3. When agreed upon by the owner and the manufacturer, any portion or any combination of tests itemized in Section 5
19、.1.1 or Section 5.1.2 may form the basis of acceptance. 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 206M/M 206-3 AASHTO 5.2. Age for AcceptancePipes shall be considered ready for acceptance w
20、hen they conform to the requirements as indicated by the specified tests. 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 206M/M 206-4 AASHTO Table 1Strength Requirements for Reinforced Concrete
21、Pipe (SI units)a Approx. Equiv. Round Size, mm T, mm Min. Rise, mm Min. Span, mm cf MPabDouble Line ReinforcementcSingle Line Reinforcement Continuous Basic Reinforcement = AsdAdditional Requirement = AsdClass Inner Cage Outer Cage “U” (Inner Cage) “V” (Outer Cage) A- II A- III A- IV A- II A- III A-
22、 IV A- II A-III A- IV Di- men- sion, mm A- II A- III A- IV Di- men- sion, mm A- II A-III A- IV A- II A-III A- IV 375 57 280 460 27.6 27.6 27.6 1.7 2.5 3.6 450 63 345 560 27.6 27.6 27.6 2.3 3.0 5.5 525 69 395 660 27.6 27.6 27.6 2.8 3.6 6.1 600 75 460 725 27.6 27.6 27.6 660 735 3.4 4.6 6.8 750 88 570
23、920 27.6 27.6 27.6 1.9 2.5 3.8 1.5 1.9 3.0 760 1.9 2.5 3.8 865 1.5 1.9 2.8 3.8 5.1 7.6 900 100 675 1110 27.6 27.6 27.6 2.3 3.2 4.6 1.9 2.5 3.6 865 2.3 3.2 4.6 990 1.9 2.5 3.4 4.6 6.3 9.3 1050 113 795 1300 27.6 27.6 27.6 2.8 3.8 5.7 2.1 3.0 4.4 1065 2.8 3.8 5.7 1090 2.1 3.0 4.6 5.5 7.6 11.4 1200 125
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOM206MM2062017STANDARDSPECIFICATIONFORREINFORCEDCONCRETEARCHCULVERTSTORMDRAINANDSEWERPIPEPDF

链接地址:http://www.mydoc123.com/p-417708.html