1、Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe Metric AASHTO Designation: M 170M-171 Technical Section: 4a, Concrete Drainage Structures Release: Group 2 (June 2017) ASTM Designation: C76M-16 American Association of State Highway and Transportation Officials 444
2、North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-4a M 170M-1 AASHTO Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe Metric AASHTO Designation: M 170M-171Technical Section: 4a, Concrete Drainage Structures Release: Group 2 (June 2017) ASTM Designation
3、: C76M-16 1. SCOPE 1.1. This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2. This specification is the metric counterpart of M 170. Note 1This specification is a manufacturi
4、ng and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends on the proper selection of the
5、class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care that installation conforms to the construction specifications. Owners of the reinforced concrete pipe specified herein are cautioned that they must correlate the field requirements with the class of pipe speci
6、fied and provide inspection at the construction site. Note 2Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (M 242M/M 242). 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 6, Fine Aggregate for Hydraulic Cement Concrete M 31M/M 31, Deform
7、ed and Plain Carbon and Low-Alloy Steel Bars for Concrete Reinforcement M 32M/M 32, Steel Wire, Plain, for Concrete Reinforcement M 55M/M 55, Steel Welded Wire Reinforcement, Plain, for Concrete M 80, Coarse Aggregate for Hydraulic Cement Concrete M 85, Portland Cement M 86M/M 86, Nonreinforced Conc
8、rete Sewer, Storm Drain, and Culvert Pipe M 154M/M 154, Air-Entraining Admixtures for Concrete M 157, Ready-Mixed Concrete M 170, Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe M 194M/M 194, Chemical Admixtures for Concrete M 221M/M 221, Steel Welded Wire Reinforcement, Deformed, for Concr
9、ete 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 170M-2 AASHTO M 225M/M 225, Steel Wire, Deformed, for Concrete Reinforcement M 240M/M 240, Blended Hydraulic Cement M 242M/M 242, Reinforced Co
10、ncrete D-Load Culvert, Storm Drain, and Sewer Pipe M 262, Concrete Pipe and Related Products M 295, Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete M 302, Slag Cement for Use in Concrete and Mortars T 280, Concrete Pipe, Manhole Sections, or Tile 2.2. ASTM Standards: A36/A36M,
11、Standard Specification for Carbon Structural Steel A706/A706M, Standard Specification for Deformed and Plain Low-Alloy Steel Bars for Concrete Reinforcement C309-03, Standard Specification for Liquid Membrane-Forming Compounds for Curing Concrete C1017/C1017M, Standard Specification for Chemical Adm
12、ixtures for Use in Producing Flowing Concrete C1116/C1116M, Standard Specification for Fiber-Reinforced Concrete 3. TERMINOLOGY 3.1. DefinitionsFor definitions of terms relating to concrete pipe, see M 262. 4. CLASSIFICATION 4.1. Pipe manufactured in accordance with this specification shall be of fi
13、ve classes identified as Class I, Class II, Class III, Class IV, and Class V. The corresponding strength requirements are prescribed in Tables 1 to 5. 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4
14、a M 170M-3 AASHTO Table 1Design Requirements for Class I Reinforced Concrete Pipea Internal Designated Diameter, mm Reinforcement, cm2/Linear m of Pipe Wall Wall A Wall B Concrete Strength, 27.6 MPa Concrete Strength, 27.6 MPa Wall Thickness, mm Circular ReinforcementbElliptical ReinforcementcWall T
15、hickness, mm Circular ReinforcementbElliptical ReinforcementcInner Cage Outer Cage Inner Cage Outer Cage 1500 125 5.3 3.2 5.9 150 4.4 2.6 4.9 1650 138 6.4 3.8 7.0 163 5.3 3.2 5.9 1800 150 7.4 4.4 8.3 175 6.1 3.7 6.8 1950 163 8.5 5.1 9.3 188 6.8 4.1 7.6 2100 175 9.5 5.7 10.6 200 7.8 4.7 8.7 2250 188
16、10.4 6.2 11.4 213 8.7 5.2 9.7 2400 200 11.4 6.8 12.7 225 9.7 5.8 10.8 Concrete Strength, 34.5 MPa Concrete Strength, 34.5 MPa 2250 213 13.3 8.0 Inner Circular Plus Elliptical 5.3 8.0 238 11.4 6.8 Inner Circular Plus Elliptical 4.6 6.8 2700 225 14.4 8.6 Inner Circular Plus Elliptical 5.8 8.6 250 12.9
17、 7.7 Inner Circular Plus Elliptical 5.2 7.7 2850 a a 3000 a a 3150 a a 3300 a a 3450 a a 3600 a a aFor modified or special designs, see Section 7.2 or, with the permission of the owner, utilize the provision of M 242M/M 242. Steel areas may be interpolated between those shown for variations in diame
18、ter, loading, or wall thickness. Pipe more than 2400 mm in diameter shall have two circular cages or an inner circular cage plus one elliptical cage. bAs an alternative to designs requiring both inner and outer circular cages, the reinforcement may be positioned and proportioned in one of the follow
19、ing manners: (1) an inner circular cage plus an elliptical cage such that the area of the elliptical cage shall not be less than that specified for the outer cage in the table, and the total area of the inner circular cage plus the elliptical cage shall not be less than that specified for the inner
20、cage in the table; (2) an inner and outer cage plus quadrant mats in accordance with Figure 1; or (3) an inner and outer cage plus an elliptical cage in accordance with Figure 2. cElliptical and quadrant steel must be held in place by means of holding rods, chairs, or other positive means throughout
21、 the entire casting operation. Note: See Section 5 for basis of acceptance specified by the owner. The strength test requirements in newtons per linear meter of pipe under the three-edge-bearing method are listed below as the D-load (test load expressed in newtons per linear meter per millimeter of
22、diameter) to produce the 0.3-mm crack and the ultimate load multiplied by the internal diameter of the pipe in millimeters. For acceptance testing requirements, see Section 11.3.1. D-load to produce a 0.3-mm crack 40.0 D-load to produce the ultimate load 60.0 2017 by the American Association of Stat
23、e Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 170M-4 AASHTO Table 2Design Requirements for Class II Reinforced Concrete PipeaInternal Designated Diameter, mm Reinforcement, cm2/Linear m of Pipe Wall Wall A Wall B Wall C Concrete Stre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOM170M2017STANDARDSPECIFICATIONFORREINFORCEDCONCRETECULVERTSTORMDRAINANDSEWERPIPEMETRICPDF

链接地址:http://www.mydoc123.com/p-417684.html