1、Section 17 SOIL-THERMOPLASTIC PIPE INTERACTION SYSTEMS 17.1 GENERAL 17.1.1 Scope The specifications of this section are intended for the structural design of plastic pipes. It must be recognized that a buried plastic pipe is a composite structure made up of the plastic ring and the soil envelope, an
2、d that both ma- terials play a vital part in the structural design of plastic pipe. 17.1.2 Notations A = area of pipe wall in square inchedfoot (Articles B = water buoyancy factor (Articles 17.2.2 and c = distance from inside surface to neutral axis (Arti- De = effective diameter = ID + 2c E = modul
3、us of elasticity of pipe material (Articles FF = flexibility factor (Articles 17.2.3 and 17.3.3) fa = allowable stress-specified minimum tensile strength divided by safety factor (Article 17.2.1) f, = critical buckling stress (Articles 17.2.2 and 17.3.2) f, = specified minimum tensile strength (Arti
4、cles 17.2.1, 17.3.1, and 17.3.2) I = average moment of inertia, per unit length, of cross section of the pipe wall (Articles 17.2.2, 17.2.3, and 17.3.3) ID = inside diameter (Articles 17.2.2, 17.3.2, and 17.4.2) M, = soil modulus (Articles 17.2.2, 17.3.2) OD = outside diameter (Article 17.4.2) P = d
5、esign load (Article 17.1.4) SF = safety factor (Article 17.2.1) T = thrust (Article 17.1.4) TL = thrust, load factor (Article 17.3.1) T, = thrust, service load (Article 17.2.1) = capacity modification factor (Article 17.3.1) 17.2.1 and 17.3.1) 17.3.2) cles 17.2.2, 17.3.2, and 17.4.2) 17.2.2 and 17.3
6、.2) 17.1.3 Loads Design load, P, shall be the pressure acting on the stnic- ture. For earth pressures see Article 3.20. For live load see Articles 3.4 to 3.7, 3.11, 3.12, and 6.4, except that the words “When the depth of fill is 2 feet or more” in Article 6.4.1 need not be considered. For loading co
7、mbinations see Article 3.22. 17.1.4 Design 17.1.4.1 The thrust in the wall shall be checked by two criteria. Each considers the mutual function of the plastic wall and the soil envelope surrounding it. The cri- teria are: (a) Wall area (b) Buckling stress 17.1.4.2 The thrust in the wall is: D T=PX y
8、 L where: P = design load, in pounds per square foot; D = diameter in feet; T = thrust, in pounds per foot. (17-1) 17.1.4.3 Handling and installation strength shall be sufficient to withstand impact forces when shipping and placing the pipe. 17.1.5 Materials The materials shall conform to the AASHTO
9、 and ASTM specifications referenced herein. 17.1.6 Soil Design 17.1.6.1 Soil Parameters The performance of a flexible culvert is dependent on soil structure interaction and soil stiffness. 43 1 432 HIGHWAY BRIDGES 17.1.6.1 The following must be considered: (a) Soils: (1) The type and anticipated beh
10、avior of the founda- tion soil must be considered; Le., stability for bedding and settlement under load. (2) The type, compacted density, and strength proper- ties of the envelope immediately adjacent to the pipe must be established. Good side fill is obtained from a granular material with little or
11、 no plasticity and free of organic material, Le., AASHTO classification groups A-1, A-2, and A-3, compacted to a minimum 90% of standard density based on AASHTO T 99 (ASTM D 698). (3) The density of the embankment material above the pipe must be determined. See Article 6.2. (b) Dimensions of envelop
12、e The general recommended criteria for lateral limits of the culvert envelope are as follows: (1) Trench installations-the minimum trench width shall provide sufficient space between the pipe and the trench wall to ensure sufficient working room to prop- erly and safely place and compact backfill ma
13、terial. As a guide, the minimum trench width should not be less than the greater of the pipe diameter plus 16.0 inches, or the pipe diameter times 1.5 plus 12.0 inches. The use of specially designed equipment may enable satisfac- tory installation and embedment even in narrower trenches. (2) Embankm
14、ent installations-the minimum width of the soil envelope shall be sufficient to ensure lateral restraint for the buried structure. The combined width of the soil envelope and embankment beyond shall be adequate to support all the loads on the pipe. As a guide, the width of the soil envelope on each
15、side of the pipe should be the pipe diameter or 2.0 feet, whichever is less. (3) The minimum upper limit of the soil envelope is 1 foot above the culvert. 17.1.7 Abrasive or Corrosive Conditions Extra thickness may be required for resistance to abra- sion. For highly abrasive conditions, a special d
16、esign may be required. 17.1.8 Minimum Spacing When multiple lines of pipes greater than 48 inches in diameter are used, they shall be spaced so that the sides of the pipe shall be no closer than one-half diameter or 3 feet, whichever is less, to permit adequate compaction of backfill material. For d
17、iameters up to and including 48 inches, the minimum clear spacing shall not be less than 2 feet. 17.1.9 End Treatment Protection of end slopes may require special consider- ation where backwater conditions may occur, or where erosion and uplift could be a problem. Culvert ends con- stitute a major r
18、un-off-the road hazard if not properly de- signed. Safety treatment, such as structurally adequate grating that conforms to the embankment slope, extension of culvert length beyond the point of hazard, or provision of guardrails, is among the alternatives to be considered. End walls on skewed alignm
19、ent require a special design. 17.1.10 Construction and Installation The construction and installation shall conform to Sec- tion 26, Division II. 17.2 SERVICE LOAD DESIGN Service Load Design is a working stress method, as tra- ditionally used for culvert design. 17.2.1 Wall Area A = T,/fa where: A =
20、 required wall area in square inches per foot; T, = thrust, service load in pounds per foot; fa = allowable stress, specified minimum tensile strength, pounds per square inch, divided by safety factor, f,/SF. (For, SF, see Article 17.4.1.2.) 17.2.2 Buckling Walls within the required wall area, A, sh
21、all be checked for possible buckling. If the allowable buckling stress, fcJSF, is less than fa, the required area must be recalculated using fcJSF in lieu of fa. The formula for buckling is: f, = 9.24 (WA) VBM, EV0.149R3 where: B = water buoyancy factor or = 1 -0.33hWk; h, = height of water surface
22、above top of pipe; h = height of ground surface above top of pipe; E = Long term (50-year) modulus of elasticity of the plastic in pounds per square inch; M, = soil modulus in pounds per square inch; = 1700 for side fills meeting Article 17.1.6; f, = critical buckling stress in pounds per square inc
23、h; 17.2.2 DIVISION 1-DESIGN 433 R = effective radius in inches = c + ID/2; A = actual area of pipe wall in square inchedfoot. 17.2.3 Handling and Installation Strength Handling and installation rigidity is measured by a flexibility factor, FF, determined by the formula: FF = D:/EI where: FF = flexib
24、ility factor in inches per pound; De = effective diameter in inches; E = initial modulus of elasticity of the pipe material in pounds per square inch; I = average moment of inertia per unit length of cross section of the pipe wall in inches to the 4th power per inch. 17.3 LOAD FACTOR DESIGN Load Fac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOHB17DIVISIONISEC172002DIVISIONIDESIGNSOILTHERMOPLASTICPIPEINTERACTIONSYSTEMS 土壤 热塑管 交互 系统 PDF

链接地址:http://www.mydoc123.com/p-417557.html