ACI 506.4R-1994 Guide for the Evaluation of Shotcrete《喷浆混凝土评估指南》.pdf
《ACI 506.4R-1994 Guide for the Evaluation of Shotcrete《喷浆混凝土评估指南》.pdf》由会员分享,可在线阅读,更多相关《ACI 506.4R-1994 Guide for the Evaluation of Shotcrete《喷浆混凝土评估指南》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、ACI 506.4R-94 became effective October 1, 1994.Copyright 1994, American Concrete Institute.All rights reserved including rights of reproduction and use in any form or by anymeans, including the making of copies by any photo process, or by electronic ormechanical device, printed, written, or oral, or
2、 recording for sound or visual reproductionor for use in any knowledge or retrieval system or device, unless permission in writingis obtained from the copyright proprietors.ACI Committee Reports, Guides, and Commentaries areintended for guidance in planning, designing, executing, andinspecting const
3、ruction. This document is intended for the useof individuals who are competent to evaluate the significanceand limitations of its content and recommendations and whowill accept responsibility for the application of the material itcontains. The American Concrete Institute disclaims any andall respons
4、ibility for the stated principles. The Institute shallnot be liable for any loss or damage arising therefrom.Reference to this document shall not be made in contractdocuments. If items found in this document are desired by theArchitect/Engineer to be a part of the contract documents, theyshall be re
5、stated in mandatory language for incorporation bythe Architect/Engineer.506.4R-1Guide for the Evaluation of ShotcreteReported by ACI Committee 506ACI 506.4R-94(Reapproved 2004)Evaluation of in-place shotcrete requires experience, education, andengineering judgment. This document serves as a guide fo
6、r engineers,inspectors, contractors, and others involved in accepting, rejecting, orevaluating in-place dry- or wet-mix shotcrete.Keywords: brooming; construction practices; cracking (fracturing);defects; dry mix; finishing; in-situ testing; inspection; lenses; nozzleman;overspray; permeability; qua
7、lity; sags; sand pockets; screeding; shotcrete;trowel cutting; visual appearance voids; wet mix.CONTENTSChapter 1Introduction, p. 506.4R-2Chapter 2Strength, p. 506.4R-22.1General2.2Destructive testing2.3Nondestructive testingChapter 3Bond and voids, p. 506.4R-33.1General3.2Sounding3.3Direct tension
8、(tensile bond)3.4Sonic and radar methods3.5Infrared thermography3.6RadiographyChapter 4Density, p. 506.4R-84.1General4.2DensityChapter 5Permeability, p. 506.4R-95.1General5.2Permeability testsChapter 6Evaluation of freshly mixed shotcrete,p. 506.4R-106.1General6.2Tests applicable for wet process sho
9、tcrete6.3Tests applicable for dry-mix process shotcreteChapter 7Determination of shotcrete mixture proportions, p. 506.4R-107.1General7.2Sampling7.3Test procedureChapter 8References, p. 506.4R-118.1Specified references8.2Cited referencesSteven H. Gebler*ChairLars Balck, Jr.SecretaryRaymond J. Schutz
10、*Subcommittee ChairSeymour A. Bortz Kristian Loevlie Vern SchultheisPaul D. Carter Dudley R. Morgan Philip T. Seabrook*Gary L. Chynoweth Dale A. Pearcey W. L. Snow, Sr.I. Leon Glassgold John E. Perry, Jr. Curt E. StraubCharles H. Henager V. Ramakrishnan*Lawrence J. TottenRichard A. Kaden*Thomas J. R
11、eading Gary L. VondranBruce K. Langson Ernest K. Schrader R. Curtis White, Jr.Albert Litvin*Members of the subcommittee that prepared this report.506.4R-2 ACI COMMITTEE REPORTCHAPTER l-INTRODUCTIONl.l-The purpose of this report is to present proceduresthat can be used to evaluate the quality and pro
12、perties ofin-place shotcrete.1.2 -Considerable literature is available on testing freshconcrete, concrete specimens, and in-place concrete. Pro-cedures for the production and testing of concrete arecovered by ACI and ASTM Standards. The developmentof in-place (nondestructive) test procedures for eva
13、l-uating concrete structures has progressed to the pointwhere the use of such procedures has become common.1.3 -Procedures for in-place evaluation of shotcrete havenot been well developed or widely used This may be dueto the lack of understanding of the difference betweenshotcrete and concrete. The
14、most important factor inproducing quality shotcrete construction is the skill of thenozzleman. While ACI 506. 2 requires preconstructiontesting to verify a nozzlemans ability, such testing is notalways done. Additionally, inspectors who are knowledge-able in shotcreting are not ordinarily available
15、to monitorshotcrete quality. Thus, if properly skilled nozzleme n arenot used, defects such as improper encasement of rein-forcing steel, voids behind steel, excessive crackingcaused by shrinkage, sand pockets, and defects caused byinclusions of overspray and rebound can occur.CHAPTER 2-STRENGTH2.1-
16、GeneralStrength is widely used to evaluate shotcrete quality.Although both compressive and flexural strength can beobtained, the compressive strength is most commonlyused. Many of the sampling and testing methods for shot-crete are similar to those used for concrete and can bebroadly categorized as
17、destructive and nondestructivedeterminations. Because it is generally not possible tomold standard test specimens for shotcrete, the samplingand testing of shotcrete are usually performed on in-place hardened material or on test panels as described inACI 506.2 and ASTM C 1140, which cover preparing
18、andtesting specimens from shotcrete test panels.2.2-Destructive testingUnder this category, samples obtained from hardenedshotcrete by drilling cores, sawing cubes, or prisms aretested to failure. Core samples are most frequently used.In addition to providing specimens for strength tests,drilled cor
19、es offer an excellent opportunity to visuallyexamine the shotcrete, at depth, for consolidation, em-bedment of reinforcement, contact with substrate, sandstreaks, and other faults, as discussed below.2.1.1 Obtaining core samples -Obtaining core samplesfrom the actual structure is not always possible
20、 and insituations where core samples can be obtained, the integ-rity of the structure may be damaged to varying degreesdepending on the size, number, and location of the coresamples. ASTM C 42 describes the testing procedure andexplains how the results should be corrected for height-to-diameter rati
21、o. The nominal core diameter should notbe less than 2 in. (50 mm) with 3 in. (75 mm) being thepreferred diameter for shotcrete. ASTM C 823 stateswhen and how cores should be taken, and the requiredmoisture condition of the cores at the time of test. It isrecommended that interpretation of results be
22、 made byan engineer experienced in shotcrete technology. Thefollowing factors should be considered:2.2.1.1 Damage to samples-Minor chipping of theperimeter of core ends during drilling is not significant.Cracks may invalidate the test result. Sharp diamond drillbits on watercooled drills rigidly fix
23、ed to the structurenormally produce suitable samples.2.2.1.2 Density -Each 1 percent of void volume inshotcrete will reduce the strength approximately 5 per-cent (Neville 1986). If undercompaction is significant,considerable voids will be present and the extent towhich it is typical of the shotcrete
24、 in the structure inquestion should be determined2.2.1.3 P resence of reinforcing bars-It is highlydesirable that cores do not contain reinforcing bars.However, there is no established standard to account forthe effect of reinforcement on the strength of the speci-men. Examination of the core failur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACI5064R1994GUIDEFORTHEEVALUATIONOFSHOTCRETE 喷浆 混凝土 评估 指南 PDF

链接地址:http://www.mydoc123.com/p-401332.html