ACI 440.2R-2008 Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (Incorporating Errata 02 27 2015)《外加固玻璃纤维强化混凝土结构的设计及建造.pdf
《ACI 440.2R-2008 Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (Incorporating Errata 02 27 2015)《外加固玻璃纤维强化混凝土结构的设计及建造.pdf》由会员分享,可在线阅读,更多相关《ACI 440.2R-2008 Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (Incorporating Errata 02 27 2015)《外加固玻璃纤维强化混凝土结构的设计及建造.pdf(80页珍藏版)》请在麦多课文档分享上搜索。
1、ACI 440.2R-08Reported by ACI Committee 440Guide for the Design and Constructionof Externally Bonded FRP Systemsfor Strengthening Concrete StructuresGuide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete StructuresEighth printingErrata as of 02/27/15ISBN 978
2、-0-87031-285-4Copyright by the American Concrete Institute, Farmington Hills, MI. All rights reserved. This materialmay not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or otherdistribution and storage media, without the written consent of ACI.The technica
3、l committees responsible for ACI committee reports and standards strive to avoid ambiguities,omissions, and errors in these documents. In spite of these efforts, the users of ACI documents occasionallyfind information or requirements that may be subject to more than one interpretation or may beincom
4、plete or incorrect. Users who have suggestions for the improvement of ACI documents arerequested to contact ACI. Proper use of this document includes periodically checking for errata atwww.concrete.org/committees/errata.asp for the most up-to-date revisions.ACI committee documents are intended for t
5、he use of individuals who are competent to evaluate thesignificance and limitations of its content and recommendations and who will accept responsibility for theapplication of the material it contains. Individuals who use this publication in any way assume all risk andaccept total responsibility for
6、 the application and use of this information.All information in this publication is provided “as is” without warranty of any kind, either express or implied,including but not limited to, the implied warranties of merchantability, fitness for a particular purpose ornon-infringement.ACI and its member
7、s disclaim liability for damages of any kind, including any special, indirect, incidental,or consequential damages, including without limitation, lost revenues or lost profits, which may resultfrom the use of this publication.It is the responsibility of the user of this document to establish health
8、and safety practices appropriate tothe specific circumstances involved with its use. ACI does not make any representations with regard tohealth and safety issues and the use of this document. The user must determine the applicability of allregulatory limitations before applying the document and must
9、 comply with all applicable laws and regulations,including but not limited to, United States Occupational Safety and Health Administration (OSHA) healthand safety standards.Order information: ACI documents are available in print, by download, on CD-ROM, through electronicsubscription, or reprint and
10、 may be obtained by contacting ACI.Most ACI standards and committee reports are gathered together in the annually revised ACI Manual ofConcrete Practice (MCP).American Concrete Institute38800 Country Club DriveFarmington Hills, MI 48331U.S.A.Phone: 248-848-3700Fax: 248-848-3701www.concrete.orgACI 44
11、0.2R-08 supersedes ACI 440.2R-02 and was adopted and published July 2008.Copyright 2008, American Concrete Institute.All rights reserved including rights of reproduction and use in any form or by anymeans, including the making of copies by any photo process, or by electronic ormechanical device, pri
12、nted, written, or oral, or recording for sound or visual reproductionor for use in any knowledge or retrieval system or device, unless permission in writingis obtained from the copyright proprietors.1ACI Committee Reports, Guides, Manuals, and Commentariesare intended for guidance in planning, desig
13、ning, executing,and inspecting construction. This document is intended for theuse of individuals who are competent to evaluate thesignificance and limitations of its content and recommendationsand who will accept responsibility for the application of thematerial it contains. The American Concrete In
14、stitute disclaimsany and all responsibility for the stated principles. The Instituteshall not be liable for any loss or damage arising therefrom.Reference to this document shall not be made in contractdocuments. If items found in this document are desired by theArchitect/Engineer to be a part of the
15、 contract documents, theyshall be restated in mandatory language for incorporation bythe Architect/Engineer.Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete StructuresReported by ACI Committee 440Fiber-reinforced polymer (FRP) systems for strengthenin
16、g concrete structuresare an alternative to traditional strengthening techniques, such as steelplate bonding, section enlargement, and external post-tensioning. FRPstrengthening systems use FRP composite materials as supplementalexternally bonded reinforcement. FRP systems offer advantages overtradit
17、ional strengthening techniques: they are lightweight, relatively easyto install, and are noncorrosive. Due to the characteristics of FRP materials aswell as the behavior of members strengthened with FRP, specific guidanceon the use of these systems is needed. This document offers general infor-matio
18、n on the history and use of FRP strengthening systems; a descriptionof the unique material properties of FRP; and committee recommendationson the engineering, construction, and inspection of FRP systems used tostrengthen concrete structures. The proposed guidelines are based on theknowledge gained f
19、rom experimental research, analytical work, and fieldapplications of FRP systems used to strengthen concrete structures.Keywords: aramid fibers; bridges; buildings; carbon fibers; concrete;corrosion; crack widths; cracking; cyclic loading; deflection; developmentlength; earthquake-resistant; fatigue
20、; fiber-reinforced polymers; flexure;shear; stress; structural analysis; structural design; torsion.CONTENTSPART 1GENERALChapter 1Introduction and scope, p. 31.1IntroductionTarek Alkhrdaji*Russell Gentry James G. Korff Andrea ProtaCharles E. Bakis Janos Gergely Michael W. Lee Hayder A. RasheedLawren
21、ce C. Bank William J. Gold Maria Lopez de Murphy Sami H. RizkallaAbdeldjelil Belarbi Nabil F. Grace Ibrahim M. Mahfouz Morris SchupackBrahim Benmokrane Mark F. Green Orange S. Marshall Rajan SenLuke A. Bisby Zareh B. Gregorian Amir Mirmiran Khaled A. Soudki*Gregg J. Blaszak Doug D. Gremel Ayman S. M
22、osallam Samuel A. Steere, IIITimothy E. Bradberry Shawn P. Gross John J. Myers Gamil S. TadrosGordon L. Brown, Jr. H. R. Trey Hamilton, III Antonio Nanni Jay ThomasVicki L. Brown Issam E. Harik Kenneth Neale Houssam A. ToutanjiRaafat El-Hacha Kent A. Harries John P. Newhook J. Gustavo TumialanGarth
23、J. Fallis Mark P. Henderson Ayman M. Okeil Milan VatovecAmir Z. Fam Bohdan N. Horeczko Carlos E. Ospina Stephanie WalkupEdward R. Fyfe Vistasp M. Karbhari Max L. Porter David White*Co-chairs of the subcommittee that prepared this document.The Committee also thanks Associate Members Joaquim Barros, H
24、akim Bouadi, Nestore Galati, Kenneth Neale, Owen Rosenboom, Baolin Wan, in addition to Tom Harmon,Renata Kotznia, Silvia Rocca, and Subu Subramanien for their contributions.John P. BuselChairCarol K. ShieldSecretaryACI 440.2R-082 DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS (ACI 440.2R-0
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACI4402R2008GUIDEFORTHEDESIGNANDCONSTRUCTIONOFEXTERNALLYBONDEDFRPSYSTEMSFORSTRENGTHENINGCONCRETESTRUCTURESINCORPORATINGERRATA02272015

链接地址:http://www.mydoc123.com/p-401305.html