ABS 213 NOTICE 3-2015 GUIDE FOR THE CLASS NOTATION HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF)).pdf
《ABS 213 NOTICE 3-2015 GUIDE FOR THE CLASS NOTATION HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF)).pdf》由会员分享,可在线阅读,更多相关《ABS 213 NOTICE 3-2015 GUIDE FOR THE CLASS NOTATION HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF)).pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、 GUIDE FOR THE CLASS NOTATION HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF) APRIL 2008 NOTICE NO. 3 October 2015 The following Rule Changes were approved by the ABS Rules Committee on 18 September 2015 and become EFFECTIVE AS OF 1 OCTOBER 2015. (See http:/www.eagle.org for the consolidated
2、 version of the Guide for the Class Notation Helicopter Decks and Facilities (HELIDK and HELIDK(SRF) 2008, with all Notices and Corrigenda incorporated.) Notes - The date in the parentheses means the date that the Rule becomes effective for new construction based on the contract date for constructio
3、n. (See 1-1-4/3.3 of the ABS Rules for Conditions of Classification (Part 1).) SECTION 2 STRUCTURAL DESIGN AND SAFETY CRITERIA 7 Arrangements (Revise Paragraph 2/7.1, as follows.) 7.1 Projections (1 October 2015) The helicopter deck is to be free of projections except that landing lights or other es
4、sential projections may be installed around the periphery of the deck provided they do not rise above the level of the helicopter deck as specified in 2/9.9.1. 9 Safety (Revise Paragraph 2/9.1, as follows.) 9.1 Safety Net (1 October 2015) 9.1.1 Vessels Safety nets for personnel protection are to be
5、installed around the periphery of the helicopter deck to the requirements provided by the flag Administration (or the cognizant authority). Those requirements are to be specified and acceptable documentation to verify compliance with those specific requirements is to be submitted to ABS. In the abse
6、nce of such requirements, a safety net as least 1.5 m (5 ft) wide is to be provided around the periphery of the helicopter deck, except where structural protection exists. The net should be inclined upwards and outwards from below the edge of the helicopter deck to a horizontal distance of 1.5 m. Th
7、e outer edge of the safety net or structural protection is not to rise more than 150 mm (6 in.) above the edge of the deck. ABSGUIDE FOR THE CLASS NOTATION HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF) .2008 1 Notice No. 3 October 2015 9.1.2 Mobile Offshore Drilling Units and other Offshor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ABS213NOTICE32015GUIDEFORTHECLASSNOTATIONHELICOPTERDECKSANDFACILITIESHELIDKANDHELIDKSRFPDF

链接地址:http://www.mydoc123.com/p-400803.html