1、 ABSGUIDE FOR PORTABLE ACCOMMODATION MODULES .2013 1 GUIDE FOR PORTABLE ACCOMMODATION MODULES JANUARY 2013 NOTICE NO. 1 May 2014 The following Rule Changes become EFFECTIVE AS OF 1 MAY 2014. (See http:/www.eagle.org for the consolidated version of the Guide for Portable Accommodation Modules 2013, w
2、ith all Notices and Corrigenda incorporated.) Notes - The date in the parentheses means the date that the Rule becomes effective for new construction based on the contract date for construction, unless otherwise noted. (See 1-1-4/3.3 of the ABS Rules for Conditions of Classification Offshore Units a
3、nd Structures (Part 1).) SECTION 1 INTRODUCTION (Revise Subsection 1/5, as follows:) 5 Application (1 May 2014) This Guide is intended for accommodation modules installed onboard ABS-classed vessels or offshore units. Industrial modules in which people normally work (laboratories, workshops, wirelin
4、e units, mudloggers, ROV control rooms, etc.) need not comply with this Guide so long as the modules are unmanned during heavy weather and sufficient space for the entire complement of personnel assigned to work in the unit(s) is provided in a deckhouse, superstructure, or module complying fully wit
5、h applicable structural requirements. A notice indicating the same is to be affixed to the module. Industrial modules are to comply with Appendix 7-2-A2 of the ABS MODU Rules or Appendix 7-A-17 of the ABS Rules for Survey After Construction (Part 7), as applicable. Non-sleeping accommodation modules
6、 are to comply with this Guide. However, the structural requirements of this Guide need not apply so long as the same conditions listed above for industrial modules are met. If non-sleeping accommodation modules are stacked, the stacking arrangements are to be reviewed and surveyed in accordance wit
7、h this Guide. Containers or portable buildings provided for storage or to house miscellaneous industrial equipment need not be considered class items. This Guide may be applied on a voluntary basis. The equipment installed in such containers or portable buildings may however be subject to additional
8、 requirements within other ABS Rules. Equipment essential to the operation of the vessel is not considered miscellaneous industrial equipment. This Guide is not applicable to modular buildings which protect against down flooding or those considered buoyant in stability or load line calculations. Thi
9、s Guide is not applicable to accommodation modules intended for Passenger Vessels or Special Purpose Ships carrying more than 60 persons. Modules intended for installation onboard this type of vessel are subject to additional requirements and will be considered on a case by case basis. This Guide is
10、 intended for modules generally not to exceed length, width, and height dimensions of 14 4.9 3 m (46 16 10 ft). Notice No. 1 March 2014 2 ABSGUIDE FOR PORTABLE ACCOMMODATION MODULES .2013 Modules constructed on or after 15 January 2013 are to comply with the requirements contained herein. Existing m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ABS193NOTICE12014GUIDEFORPORTABLEACCOMMODATIONMODULESPDF

链接地址:http://www.mydoc123.com/p-400733.html