API RP 11S-1994 Recommended Practice for the Operation Maintenance and Troubleshooting of Electric Submersible Pump Installations (THIRD EDITION)《电动潜水泵安装作业.维护和故障解决方法》.pdf
《API RP 11S-1994 Recommended Practice for the Operation Maintenance and Troubleshooting of Electric Submersible Pump Installations (THIRD EDITION)《电动潜水泵安装作业.维护和故障解决方法》.pdf》由会员分享,可在线阅读,更多相关《API RP 11S-1994 Recommended Practice for the Operation Maintenance and Troubleshooting of Electric Submersible Pump Installations (THIRD EDITION)《电动潜水泵安装作业.维护和故障解决方法》.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、Recommended Practice for the Operation, Maintenance and Troubleshooting of Electric Submersible Pump InstallationsAPI RECOMMENDED PRACTICE 11STHIRD EDITION, NOVEMBER 1994REAFFIRMED, OCTOBER 2013Recommended Practice for the Operation, Maintenance and Troubleshooting of Electric Submersible Pump Insta
2、llationsUpstream SegmentAPI RECOMMENDED PRACTICE 11STHIRD EDITION, NOVEMBER 1994REAFFIRMED, OCTOBER 2013API RP*LLS 94 W 0732290 0539049 297 m SPECIAL NOTES API publications necessarily address problems of a general nature. With respect to par- ticular circumstances, local, state, and federal laws an
3、d regulations should be reviewed. API is not undertaking to meet the duties of employers, manufacturers, or suppliers to warn and properly train and equip their employees, and others exposed, concerning health and safety risks and precautions, nor undertaking their obligations under local, state, or
4、 federal laws. Information concerning safety and health risks and proper precautions with respect to particular materials and conditions should be obtained from the employer, the manufacturer or supplier of that material, or the material safety data sheet. Nothing contained in any API publication is
5、 to be construed as granting any right, by im- plication or otherwise, for the manufacture, sale, or use of any method, apparatus, or prod- uct covered by letters patent. Neither should anything contained in the publication be construed as insuring anyone against liability for infringement of letter
6、s patent. Generally, API standards are reviewed and revised, reaffirmed, or withdrawn at least ev- ery five years. Sometimes a one-time extension of up to two years will be added to this re- view cycle. This publication will no longer be in effect five years after its publication date as an operativ
7、e API standard or, where an extension has been granted, upon republication. Status of the publication can be ascertained from the API Authoring Department telephone (214) 953-1 1011. A catalog of API publications and materials is published annually and up- dated quarterly by API, 1220 L Street, N.W.
8、, Washington, D.C. 20005. This document was produced under API standardization procedures that ensure appro- priate notification and participation in the developmental process and is designated as an API standard. Questions concerning the interpretation of the content of this standard or comments an
9、d questions concerning the procedures under which this standard was devel- oped should be directed in writing to the director of the Exploration and Production Depart- ment, American Petroleum Institute, 700 North Pearl, Suite 1840, Dallas, Texas 75201. Requests for permission to reproduce or transl
10、ate all or any part of the material published herein should also be addressed to the director. API publications may be used by anyone desiring to do so. Every effort has been made by the Institute to assure the accuracy and reliability of the data contained in them; however, the Institute makes no r
11、epresentation, warranty, or guarantee in connection with this pub- lication and hereby expressly disclaims any liability or responsibility for loss or damage re- sulting from its use or for the violation of any federal, state, or municipal regulation with which this publication may conflict. API sta
12、ndards are published to facilitate the broad availability of proven, sound engineer- ing and operating practices. These standards are not intended to obviate the need for applying sound engineering judgment regarding when and where these standards should be utilized. The formulation and publication
13、of API standards is not intended in any way to inhibit anyone from using any other practices. Any manufacturer marking equipment or materials in conformance with the marking re- quirements of an API standard is solely responsible for complying with all the applicable requirements of that standard. A
14、PI does not represent, warrant, or guarantee that such prod- ucts do in fact conform to the applicable API standard. Copyright O 1994 American Petroleum Institute CONTENTS SCOPE . OPERATION . 2.1 Checks Before Start-up . 2.2 System Start-up . 2.3 Adjustments After Well Stabilization 2.4 Operating Da
15、ta Gathering 2.5 Analyzing Operating Data . TROUBLESHOOTING . 3.1 Historical Operating Information for the Producing Area . 3.2 Ammeter Chart Analysis 3.3 Basic Problem Troubleshooting . MAINTENANCE . 4.1 Preventative Maintenance with Well Down and with Primary Power Disconnected . 4.3 Equipment and
16、 System Maintenance . 4.2 Preventative Maintenance Checks with System Operating Figures l-well Equipment . 2-Production Test Data Sheet 3 . 4 . 5 . 6 . 7 . 8 . 9 . 10 . 11 . 12 . 13 . 14 . 15 . 16 . 17 . Page 1 1 1 1 2 2 2 2 2 3 10 15 15 15 15 1 3 4 4 4 5 5 6 6 6 7 7 8 8 8 9 9 API RP*33S 94 m 073229
17、0 0539053 945 W FOREWORD This recommended practice (RF) is under the jurisdiction of the American Petroleum In- stitute (API) Committee on Standardization of Production Equipment. This document presents recommended practices for the operation, maintenance, and troubleshooting of electric submersible
18、 pumps and auxiliary equipment. This recommended practice is provided to meet the need for guidelines, procedures, and recommendations cov- ering electric submersible pumping equipment. These recommended practices are those generally considered necessary for successful submersible pump operation. Th
19、is standard shall become effective on the date printed on the cover but may be used voluntarily from the date of distribution. v API RP*llS 94 0732290 0539052 881 Recommended Practice for the Operation, Maintenance and Troubleshooting of Electric Submersible Pump Installations 1 Scope This recommend
20、ed practice covers all of the major components that comprise a standard electric submersible pumping system, their operation, maintenance, and trou- bleshooting. It is specifically prepared for installations in oil and water producing wells where the equipment is installed on tubing. It is not prepa
21、red for equipment selection or application. 2 Operation 2.1 CH.ECKS BEFORE START-UP 2.1.1 Make certain that the flowline hookup is completed, that all valves are of proper pressure ratings and are properly installed, including an adjustable tubing choke. All valves should be in their proper operatin
22、g position (open or closed, as appropriate). WARNING: A master or wing valve on the tubing could be exposed to the maximum discharge pressure of the pump when the fluid in the annulus is at the surface. Therefore, these valves must be able to withstand this pressure. 2.1.2 Check no-load voltage, pot
23、ential, and current trans- formers for proper ratios, and adjust the underload and over- load relays to proper setting for start-up according to the manufacturers or users specifications. Check to see that all the power fuses are sized properly for the downhole equip- ment. 2.1.3 Assure that other s
24、ystem relays and controls are in proper adjustment or position, and electrical connections are clean and tight. The system must be properly grounded and the junction box properly installed, including a cable vapor seal between the junction box and motor control panel. 2.1.4 Make certain that the pro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- APIRP11S1994RECOMMENDEDPRACTICEFORTHEOPERATIONMAINTENANCEANDTROUBLESHOOTINGOFELECTRICSUBMERSIBLEPUMPINSTALLATIONSTHIRDEDITION

链接地址:http://www.mydoc123.com/p-399972.html