HD 586 1 S1-1994 Mineral Insulated Cables with a Rated Voltage not Exceeding 750 V Part 1 Cables《额定电压不超过750 V的矿物绝缘电缆 第1部分 电缆》.pdf
《HD 586 1 S1-1994 Mineral Insulated Cables with a Rated Voltage not Exceeding 750 V Part 1 Cables《额定电压不超过750 V的矿物绝缘电缆 第1部分 电缆》.pdf》由会员分享,可在线阅读,更多相关《HD 586 1 S1-1994 Mineral Insulated Cables with a Rated Voltage not Exceeding 750 V Part 1 Cables《额定电压不超过750 V的矿物绝缘电缆 第1部分 电缆》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、Rue de Stassart 35 - B - 1050 Bruxelles Td.: (+32 2) 618 68 71 -Fu: (+32 2) 618 69 18 Hinrr8l inrulatod erblos with 1 r8tOd voltage not oxceeding 750 V Part 1: Cables HO 586.1 $1 SHEET Issue 1 1994-01-31 JtnU8ty 199) Cibler 8 isolant mineral, de Hinrralisoliorte Leitungen mit einer tension assigne n
2、o diprrsrnt pas Nennrpannung bis 150 V IS0 V foil 1: Loitungon Partie 1: Cibles Related to Directive: 73123lEEC This Harmonization Document consists of the following: - Title Page - Text prepared by CENELEC Technical Comnittee TC 20 date of ratification : 1993-09-22 date of announcement : 1994-02-01
3、 date of latest publication : 1994-08-01 date of withdrawal : 1994-08-01 - LIST OF NATIONAL STANDARDS, IF ANY, IS 6IVEN OVERLEAF - HARHONIZATION DOCUMENT HO 506.1 S1 DOCUHENT DHARMONISATION HARMONfSIERUN6500KUHENT hU8ry 1994 _ UDC 621.315.2:621.315.613:621.3.027.26 Doscriptors: Eloctric instrllrtion
4、, inSUl8ted conductor, inrulrtod crblo, mineral matorial, tpocificrtion, dimension, tost, marking ENGLISH VERSION Mineral inrulrtod C8blOS with 8 rated voltrgo not excooding 750 V P8rt 1: CrblOr Ciblos 8 isolant ninirrl, do tonsion asrignie no diprrrrnt Partio 1: Cibler g8S 750 v Hinorrlirolirrte Lo
5、itungon nit 8in.r NOnnrP8nnUng bis 750 V Toil 1: Loitungon This Harmonization Document was approvod by CENELEC on 1993-09-22. CENELEC members are bound to comply with,the CENICENELEC Intornal Regulations which stipulate the conditions for implementation of this Harmonization Document on a national l
6、evel. Up-to-date lists and bibliographical references concerning national implomentation may be obtained on application to the Central Socretrriat or to any CENELEC momber. .- This Harmonization Document oxirtr in three official versions (English, French, German 1, CENELEC members are the national e
7、lectrotechnical committees of Austria, Belgium, Denmark, Finland., Frrnco, Gormany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, $pain, Sweden, SWitterlrnd rnd United Kingdom. CENELEC European Conmittee for Eloctrotochnical Strndardization Comit Europen de Normalisatio
8、n Electrotechnique Europaisches Komitoe fr Eloktrotechnische Normung Cintra1 Socrotariat: ruo do Strrrart 35, 8-1050 Brusrolr 1994 Copyright reserved to CENELEC nombers Ref. No. HD 586.1 S1:1994 E -i- 1 Page 2 - _ HD 586.1 S1:1994 m 3404583 OLL4038 02T m FOREWORD This Harmonization Document was prep
9、ared by CENELEC Technical Committee TC 20, Electric Cables. The text of the draft was submitted to the CENELEC Unique Acceptance Procedure (UAP) in January 1993 and was approved by CEWELEC as HD 586.1 S1 on 22 September 1993. Tne foliowing dates were fixed: - latest ate of announcement of the HD at
10、national level - latest date of publication of a harmonized national standard (dop) 1994-08-01 - iatest iate of withdrawal of confiicting national standaras (daw) 1994-08-01 For products which have complie with the relevant national standard before i994-08-01, as shown by the manufacturer or Dy a ce
11、rtification boy, this previous sranaard may continue to appiy for production until 1995-08-01. NOZ: Requirements for terminations for use with the cables described in this Part 1 of HD 586 are given in Part 2: Terminations. References are made, in this HD 586.1 to other Harmonisation Documents and I
12、nternational Standards as follows: HD21 Polyvinyl chloride insulated cables of voltages up to and including 450/750V HD405.1 Tests on Electric Cables Under Fire Conditions. Part 1 : Test on a single vertical cable (Endor! HD505 Common test methods for insulating and sheathing materials of Electric C
13、ables (Endorsing IEC 811) HD602 Test on gases evolved during combustion of materials from cables: Determination of Degree Acidity (Corrosivity) of gases by measuring pH and conductivity (Endorsing IEC 754-2) HD606 Measurement of smoke density of electric cables burning under defined conditions (Endo
14、rsing IEC 1034) IEC33 1 Fire resisting charactefistics of electric cables. IEC 332-1 I (doa) 1994-02-01 Page 3 - 3404583 0334039 Tbb HD 586.1 S1 :i994 CONTENTS eane 2. Obiect 3. Voltaoe Ratinp 3.1 500V mineral insulated cable (light duty grade) 3.2 750V minerai insulated cable (heavy duty grade) 4.
15、o nductors 4.1 Material and form 4.2 Resistance 5. Insulation 5.1 Material 5.2 Resistance 5.3 Thickness 5.4 Dielectric strength 6. Sheath 6.1 Material 6.2 Thickness 6.3 integrity 6.4 Diameter over copper sheath 6.5 Electrical resistance 7. Outer Covering 7.1 General 7.2 Material 7.3 Optional perform
16、ance requirements under fire conditions 8. Comdete Cable 8.1 Bending 8.2 Flattening 8.3 Fire Resistance 8.4 Voltage 9. Marking 10. Cable Tests 10.1 General 10.2 Test Conditions Appendix A - Test Methods for Type and Sample Tests Appendix B - Test Methods for Routine Tests Tables 1-1 1 Figures 1-2 Pa
17、ge 4 HD 586.1 S1:1994 - 1. 2. 3. 4. MINERAL INSULA TED CAMS WITH A RATED Vol T AGE NO T FXCEED ING 750 V ScoPe This standard applies to mineral insulated general wifing cables with copper sheath and copper conductors with rated voltages up to 750V. Ptovkion s made for a corrosion resistant mer covet
18、inp over the sheath, when required. This outer coveting is not rpecfed for the purposes of electrical insulation of the metal sheath. * Obiect The object of this standard is to specify mineral insulated cables that are safe and reliable when properly used, to state the manufacturing requirements and
19、 characteristics to achieve this, rnd to specify methods for checking conformiry witti those requirements. Cables shall be rated as follows: 3.1 500V mineral insulated cab le liaht dutv P rade) For use where the voltage between conductors and sheath and between conductors does not exceed 500V r.m.s.
20、 or 500V d.c. 3.2 750V mineral insulated cab le heaw dutv a radel For use where the voltage between conductors and sheath and between conductors does not exceed 750V r.m.s. or 750V d.c. Conductors 4.1 Material and Form Conductors shall be of plain, annealed high conductivity copper. The cross sectio
21、n shall be approximately circular. 4.2 Resistance The resistance of all conductors of each finished cable, corrected if necessary to 2OoC shall not be greater than the appropriate values given in Tables 1 and 2. Compliance shall be checked by measuring the resistance of each conductor of each comple
22、te coil of completed cable and meas,uring the length of the cable. jmrhclc. 02 5 3404583 OLL404L bL4 Page 5 HD 586.1 s1:1994 If necessary, correction to 2OoC and to a kngth of 1 km shall be nude by apPlying th formula: lo00 x- 254.5 Ra3 4 m.5 + t L in which: t R, L R, is the temperature of the cable
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HD5861S11994MINERALINSULATEDCABLESWITHARATEDVOLTAGENOTEXCEEDING750VPART1CABLES 额定 电压 不超过 750 矿物 绝缘 电缆

链接地址:http://www.mydoc123.com/p-1341429.html