《HD 22 12 S1 A1-1999 AMD 1 Rubber Insulated Cables of Rated Voltages up to and Including 450 750 V Part 12 Heat Resistant EPR Cords and Flexible Cables《修改件1 额定电压.pdf》由会员分享,可在线阅读,更多相关《HD 22 12 S1 A1-1999 AMD 1 Rubber Insulated Cables of Rated Voltages up to and Including 450 750 V Part 12 Heat Resistant EPR Cords and Flexible Cables《修改件1 额定电压.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、HD 22.12 SIIA1 HARMONIZATION DOCUMENT DOCUMENT DHARMONISATION HARMONISIERUNGSDOKUMENT January 1999 ICs 29.060.20 Descriptors: Insulated conductor, insulated cable, flexible cable, rubber, ethylene-propylene, heat resistant material, protective sheath, insulation, designation, construction, dimension
2、, test, data table English version Rubber insulated cables of rated voltages up to and including 450/750 V Part 12: Heat resistant EPR cords and flexible cables Conducteurs et cbles isols au caoutchouc de tension assigne au plus gale 450/750 V Partie 12: Cbles souples isolation EPR rsistant ia chale
3、ur Gummi-isolierte Leitungen mit Nennspannungen bis 450/750 V Teil 12: Wrmebestndige Schlauchleitungen mit EPR Isolierhlle This amendment Al modifies the Harmonization Document HD 22.1 2 S1:1996; it was approved by CENELEC on 1998-08-01. CENELEC members are bound to comply with the CENKENELEC Intern
4、al Regulations which stipulate the conditions for implementation of this amendment on a national level. Up-to-date lists and bibliographical references concerning such national implementation may be obtained on application to the Central Secretariat or to any CENELEC member. This amendment exists in
5、 three official versions (English, French, German). CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United K
6、ingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Centrai Secretariat: rue de Stassart 35, B - 1050 Brussels 1999 CENELEC - All rights of exploitation in any form and by any means r
7、eserved worldwide for CENELEC members. Ref. No. HO 22.12 S1:1996/A1:1999 E Page 2 HD 22.12 S1:1996/A1:1999 Foreword This amendment was prepared by the Technical Committee CENELEC TC20, Electric cables, and agreed at the Dublin meeting (April 1997) to go forward to the Unique Acceptance Procedure. Th
8、is amendment has been prepared within the regular maintenance programme which covers all Parts of HD 22. Attention is especially drawn to Annex X and Annex Y, which will be incorporated into HD 22.1 and HD 516 at a later date. The text of the draft was submitted to the Unique Acceptance Procedure an
9、d was approved by CENELEC as amendment Al to HD 22.12 S1:1996 on 1998-08-01. The following dates were fixed: - latest date by which the existence of the amendment has to be announced at national level (doa) 1996-1 2-01 - latest date by which the amendment has to be implemented at national level by p
10、ublication of a harmonized national standard or by endorsement (dop) 1999-06-01 - latest date by which the national standards conflicting with the amendment have to be withdrawn (daw) 2000-06-01 Page 3 HD 22.12 51:1996/A1:1999 Amendment AI to HD 22.12 SI Clause 2 Delete HD 405.1 Insert: EN 50265-2-1
11、 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1 : Procedures - 1 kW pre- mixed flame Clause 3 Amend title to read: “Ordinary heat-resistant and low-temperature resistant EPR . . .“ Sub-clau
12、se 3.3.3 In line 1, amend “El 7“ to “El 6“ Sub-clause 3.3.7 Amend the end of the sub-ciause to read: I Part 1, sub-clause 3.2“ Clause 4 Amend title to read: “Heavy heat-resistant and low-temperature resistant EPR . . “ Sub-clause 4.3.3 In line 1, amend “EI 7“ to “Ei 6“ Sub-clause 4.3.8 Amend the end
13、 of the sub-ciause to read: “ Part 1, sub-clause 3.2“ Sub-clause 5.3.7 Amend the end of the sub-clause to read: “ Part 1, sub-clause 3.2“ Table VI Against Ref No.6 put “50265-2-1“ in column 4 in place of “405.1“ STDeCENELEC HD 22.12 SL/AL-ENGL 1977 m 3404583 0387888 T81 Page 4 HD 22.12 S1:1996/A1:19
14、99 Sub-clause 6.3.8 Amend the end of the sub-ciause to read: I Part 1, sub-ciause 3.2“ Table VIII Against Ref No.6 put “50265-2-1“ in column 4 in place of “405.1“ Sub-clause 7.3.8 Amend the end of the sub-clause to read: “ Part 1, sub-clause 3.2“ Table IX Amend the reference in Note (1 ) to read “IE
15、C 60502-1, Annex A“. Table X Delete existing Table X and replace as attached. Annex A Delete reference to IEC 502 and insert: “IEC 60502-1 “Power Cables with extruded insulation and their accessories for rated voltages 1 kV (U, = 1,2kV) up to 30kV (U, = 36kV) - Part 1 : Cables for rated voltages of
16、1 kV (U, = 1,2kV) and 3kV (U, = 3,6kV)“ Annex B Add new Annex B as attached. Annex c Add new Annex C as attached. Page 5 HD 22.12 S1:1996/A1:1999 Table X Tests for TvDe H07BN4-F 2 Tests Electrical tests Resistance of conductors Voltage test on cores at 2500V Voltage test on completed cable at 2500V
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HD2212S1A11999AMD1RUBBERINSULATEDCABLESOFRATEDVOLTAGESUPTOANDINCLUDING450750VPART12HEATRESISTANTEPRCORDSANDFLEXIBLECABLES

链接地址:http://www.mydoc123.com/p-1340811.html