HD 22 1 S2 A19-1995 AMD 19 Rubber Insulated Cables of Rated Voltages up to and Including 450 750 V Part 1 General Requirements《修改件19 额定电压450 750 V及以下的橡胶绝缘电缆 第1部.pdf
《HD 22 1 S2 A19-1995 AMD 19 Rubber Insulated Cables of Rated Voltages up to and Including 450 750 V Part 1 General Requirements《修改件19 额定电压450 750 V及以下的橡胶绝缘电缆 第1部.pdf》由会员分享,可在线阅读,更多相关《HD 22 1 S2 A19-1995 AMD 19 Rubber Insulated Cables of Rated Voltages up to and Including 450 750 V Part 1 General Requirements《修改件19 额定电压450 750 V及以下的橡胶绝缘电缆 第1部.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、c HARMONIZATION DOCUMENT HD 22.1 S2lA19 DOCUMENT DHARMONISATION HARMONISIERUNGSDOKUMENT June 1995 UDC 621.31 5.21 1.2.027.457-777.1 /.2-777.6.001.2.002.2.001.4(083.71)(083.73)621.315.616 ICs 29.060.20 Descriptors: See HD 22.1 S2:1992 English version Rubber insulated cables of rated voltages up to an
2、d including 450/750 V Part 1 : General requirements Conducteurs et cbles isols au caoutchouc, de tension assigne au plus gale 450/750 V Partie 1 : Prescriptions gnrales Isolierte Starkstromleitungen mit einer Isolierung aus Gummi mit Nennspannungen bis 450/750 V Teil 1 : Allgemeine Anforderungen Thi
3、s amendment A19 modifies the Harmonization Document HD 22.1 S2:1992; it was approved by CENELEC on 1995-05-15. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for implementation of this amendment on a national level. Up-to-date lists and bi
4、bliographical references concerning such national implementation may be obtained on application to the Central Secretariat or to any CENELEC member. This amendment exists in three official versions (English, French, German). CENELEC members are the national electrotechnical committees of Austria, Be
5、lgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr
6、Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels * 1995 Copyright reserved to CENELEC members Ref. No. HD 22.1 C2:1992/A19:1995 E _ - CENELEC HD*ZZ-L*SZ/ A19 95 3404583 0159449 778 Page 2 ? HD 22.1 S2: 1 992/A19: 1 995 Foreword This amendment was prepared by the T
7、echnical Committee CENELEC TC 20, Electric cables. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A19 to HD 22.1 S2:1992 on 1995-05-15. The following dates were fixed: - latest date by which the existence of the amendment has to be ann
8、ounced at national level - latest date by which the amendment has to be implemented at national level by publication of a harmonized national standard or by endorsement - latest date by which the national standards conflicting with the amendment have to be withdrawn (doa) 1996-01-01 (dop) 1996-07-01
9、 (daw) 1996-07-01 For products which have complied with HD 22.1 S2:1992 and its amendments A1 1 :1992 to A18:1995 before 1996-07-01, as shown by the manufacturer or by a certification body, this previous standard may continue to apply for production until 1997-07-01. P Page 3 HD 22.1 S2:1992/A19:199
10、5 Sub-clause 5.2.1 Insert new lines: Type EI 8 for flexible cables insulated with polyolefin-based cross-linked compound having a low level of emission of corrosive gases. 7OoC for compound EI 8. Table 1 Reauirements for the non electrical test for vulcanis. ed rubber insulation Insert new column fo
11、r EI 8 as attached. Sub-clause 5.5.1 insert new lines: Type EM 8 for flexible cables sheathed with polyolefin-based cross-linked compound, having a low level of emission of corrosive gases. Table II Reauirements for the non electrical test for vulcanised rubber sheath insert new column for EM 8 as a
12、ttached. Table III Add new ref. no. 5 Long term resistance of insulation to direct current as attached. CENELEC HD*22*l*S2/ AL9 95 3404583 OL5945L 346 6 Page 4 HD 22.1 S2: 1992/A19: 1995 6 TABLE I Reauirements for the non-electrical tests for vulcanised rubber insulation 1 Ref. No. 1. 1.1 1.1.1 1.1.
13、2 1.2 1.2.1 1.2.2 1.2.3 1.3 1.4 2 Tests Maximum rated conductor temperatures Tensile strenath and elonaation at break Properties in the state as delivered Value to be obtained for the tensile strength: - median, min. Value to be obtained for the elongation at break: - median, min. Properties after a
14、geing in air oven Ageing conditions: (2)(4) - temperature - duration of treatment Value to be obtained for the tensile strength: - median, min. - variation il), max. Value to be obtained for the elongation: - median, min. - variation (1). max. (Spare) (Soarei - 3 Unit OC N/mm % OC h Nlmm YO % Oh 4 T
15、ype of compound El8 70 6.0 126 110f2 7 x 24 -30 (3) 126 f 30 HD 505.1.1 505.1.2 Clause 9.1 8.1.3.2a CENELEC HD*ZZ.L*SZ/ AL9 95 I 3404583 0359452 282 6 1 Ref. No. 1.6 1.6.1 1.6.2 1.6.3 2. 2.1 2.2 3. 4. 4.1 4.2 5. 5.1 5.1.1 6.1.2 6 Page 5 HD 22.1 S2:1992/A19:1995 TABLE I jcontinuedl 2 Tests Vlaximum r
16、ated conductor temperature roperties after ageing in the air bomb 4geing Conditions (4) temperature . duration of treatment Value to be obtained for the tensile strength: . median, min. . variation, (1 ) max. Value to be obtained for the elongation Bt break . median, min. - variation, max. Hot set t
17、est Conditions of treatment - temperature - time under load - mechanical stress Test requirements - max. elongation under load - max. elongation under unloading (Spare) Ozone resistance test Method A Test conditions - test temperature - test duration - ozone concentration Method B Test conditions -
18、test temperature - test duration - ozone concentration Low temoerature tests Bending test Test conditions - temperature - period of application of low temperature Result to be obtained 3 Unit OC OC h Nlrnm Oh % % OC min. N/cm2 % % OC h PPm OC h PPhm OC 4 Type of compound El8 70 nla 200 i 3 16 20 1 O
19、0 25 25*2 24 260 to 300 40k2 72 200 f 60 nia HD 606.1.2 605.2.1 505.2.1 22.2 505.1.4 see 606.1.4 sub- clause 8.1.4 and 8.1.6 Clause 8.2 9 8 7 8.1 _- CENELEC HD*ZZ*L*SZ/ AL9 95 3404583 0159453 119 Page 6 HD 22.1 S2: 1992/A19:1995 TABLE I jconcluded) 1 Ref. No. 6.2 6.2.1 5.2.2 6. 7. 7.1 7.2 7.3 NOTES
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HD221S2A191995AMD19RUBBERINSULATEDCABLESOFRATEDVOLTAGESUPTOANDINCLUDING450750VPART1GENERALREQUIREMENTS

链接地址:http://www.mydoc123.com/p-1340807.html