HD 187 S4-1989 A C Metal-Enclosed Switchgear and Controlgear for Rated Voltages above 1KV and up to and Including 72 5 KV《额定电压1 KV以上至72 5 KV及以下交流金属封闭开关设备和控制设备》.pdf
《HD 187 S4-1989 A C Metal-Enclosed Switchgear and Controlgear for Rated Voltages above 1KV and up to and Including 72 5 KV《额定电压1 KV以上至72 5 KV及以下交流金属封闭开关设备和控制设备》.pdf》由会员分享,可在线阅读,更多相关《HD 187 S4-1989 A C Metal-Enclosed Switchgear and Controlgear for Rated Voltages above 1KV and up to and Including 72 5 KV《额定电压1 KV以上至72 5 KV及以下交流金属封闭开关设备和控制设备》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、.* .i 1 1 . 1% fr: - ._ ,i,$.?, d sac: *- -. . - . A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 72.5 kV . rET*q:y,w .E - According to the CENELEC Internal Regulations the CENELEC member National Committees are bound: to announce the existence o
2、f this Harmonization Document at national level by Or beforo 1989-9-15 - _. - to publish their new harmonized irationa1 standard by or before 1990-03-15 CO withdraw a11 conflicting national standards by or before 1990-03-15. : _. .= The CENELEC National Committees are the national electrotechnical c
3、ommittees of Austria, Belgium, Denmark, FinlaVd, France, Germany, Gree.:e, fceliind, Ireiand, - italy. uxemburg, Netherlands, Norway, Portugal, Spain, Sweden, Switzarland and United Kingdom. - -4 A- .? - - i. - . .-fi a Copyright reserved to all CENELEC members - HD 187 - Page 2 FOREWORD This Harino
4、nization Cocument was prepared by CENELEC TC 17C and sup2rsedes HD 187 S3. -: - - The testfinger is stan- dardized in HD 365 S3 -:. (IEC Pblicaticn 5291,. i -1 ro TECHNICAL ANNEX PARTIAL DISCEARGE TESTS .-. -L ,.: 1. General . The measurement of partial discharges is a suitable means2of detecting ce
5、rtain defects in the equipment under test and is a useful complement to the dielectric tests. Experience shows that partial discharges may lead in particular arrangements to a progressive degradation in tge dielectric strength of the insulation, especially of solid insulation. On the other hand, it
6、is not yet possible to establish a reliable relationship between the results of partial discharge measurements an the life expectancy of the equipment owing to the complexity of the insulation systems y:- used in - . .- -_ metal-enclosed switchgear and controlgear. .- /. - - . 1. -. _. - - - _- 2. A
7、pplication The measurement of partial discharges is recommended forcgetal-enclosed switchgear and controlgear if organic insulation materiax are largely Used therein. .- Because of the design variations a general specification-zor the test object cannot be given. In general, the test object should c
8、onsi$t of assemblies or sub-assemblies with dielectric stresses which are identicl .- to those which -. ._- would occur in the complete assembly of the equipment. - . a. Notes 1. - 2. - i. - lest objects consisting of a complete assembly are to be -I preferred. In the case of integrated switchgear d
9、esign, -.$- especially uhere various live parts and connections are ecgedded in solid insulation, tests on a complete asseiblv are nec-SsarY. .-ype test to show, in correlation with the other dielectric tests, if and where there are weak points with respect to the dielectric stresses resulting fgtm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HD187S41989ACMETALENCLOSEDSWITCHGEARANDCONTROLGEARFORRATEDVOLTAGESABOVE1KVANDUPTOANDINCLUDING725KV 额定

链接地址:http://www.mydoc123.com/p-1340776.html