《ISO TR 23211-2009 Hydrometry - Measuring the water level in a well using automated pressure transducer methods《液体比重测定法 自动压力传感器法测定井中的水位》.pdf》由会员分享,可在线阅读,更多相关《ISO TR 23211-2009 Hydrometry - Measuring the water level in a well using automated pressure transducer methods《液体比重测定法 自动压力传感器法测定井中的水位》.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference number ISO/TR 23211:2009(E) ISO 2009TECHNICAL REPORT ISO/TR 23211 First edition 2009-07-01 Hydrometry Measuring the water level in a well using automated pressure transducer methods Hydromtrie Mthodes automatises, utilisant des transducteurs de pression, pour mesurer le niveau deau dans u
2、n puits ISO/TR 23211:2009(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editin
3、g. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be fo
4、und in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at th
5、e address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2009 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from eith
6、er ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reservedISO/TR 23211:2009(E) IS
7、O 2009 All rights reserved iiiContents Page Foreword .v Introductionvi 1 Scope1 2 Normative references1 3 Terms and definitions .1 4 Applications of the use of pressure transducers to ground-water resource investigations 1 4.1 Ground-water monitoring .1 4.2 Long-term monitoring.2 4.3 Short-term moni
8、toring 4 4.4 Reducing well-bore storage .4 5 Planning considerations for sensor systems.8 5.1 General .8 5.2 Study duration and system reliability .8 5.3 Required accuracy 8 5.4 Installation location and site accessibility9 5.5 System components and compatibility.9 5.6 Water quality 9 5.7 Number of
9、wells.9 5.8 Well location, diameter and depth .10 5.9 Data-collection frequency.10 5.10 Data transfer 11 5.11 Cost.11 6 Assembly, calibration and testing .11 6.1 General .11 6.2 Familiarization with transducer performance.11 6.3 Linear transducer calibration.13 6.4 Sources of error in linear calibra
10、tions 14 6.5 Temperature-corrected transducer calibration 14 7 Installation16 7.1 General .16 7.2 Care and handling .17 7.3 Shelter.18 7.4 Power requirements 19 7.5 Hanging transducers in wells 20 7.6 Measuring system drift .22 7.7 Desiccation systems .23 7.8 Transducer field calibration .23 7.9 Opt
11、imizing measurement-system performance.26 8 Data collection .27 8.1 General .27 8.2 Frequency of visits27 8.3 Field checks .27 8.4 Data recording and retrieval.28 8.5 Verification .30 8.6 Use with data loggers .30 8.7 Field documentation .30 8.8 Maintenance.30 ISO/TR 23211:2009(E) iv ISO 2009 All ri
12、ghts reserved9 Data processing.31 9.1 General31 9.2 Adjustments .31 9.3 Documentation.31 Annex A (informative) Pressure transducers Characterization, common problems and solutions .33 A.1 Pressure transducer characterization .33 A.1.1 General33 A.1.2 Types of pressure measurements .33 A.1.3 Common p
13、ressure units used in hydrology .34 A.1.4 Basic types of transducers for measuring pressure .35 A.1.5 Understanding pressure-transducer specifications 47 A.2 Common problems and solutions53 A.2.1 General53 A.2.2 Leakage.53 A.2.3 Open and short circuits 55 A.2.4 Grounding problems .56 A.2.5 Diaphragm
14、 failure 56 A.2.6 Power-supply failure .56 A.2.7 Data logger channel failure.56 A.2.8 Voltage surges .57 A.2.9 Faulty shielding57 A.2.10 Over-range problems 57 Bibliography 58 ISO/TR 23211:2009(E) ISO 2009 All rights reserved vForeword ISO (the International Organization for Standardization) is a wo
15、rldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented o
16、n that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted
17、 in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standa
18、rd requires approval by at least 75 % of the member bodies casting a vote. In exceptional circumstances, when a technical committee has collected data of a different kind from that which is normally published as an International Standard (“state of the art”, for example), it may decide by a simple m
19、ajority vote of its participating members to publish a Technical Report. A Technical Report is entirely informative in nature and does not have to be reviewed until the data it provides are considered to be no longer valid or useful. Attention is drawn to the possibility that some of the elements of
20、 this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO/TR 23211 was prepared by Technical Committee ISO/TC 113, Hydrometry, Subcommittee SC 8, Ground water. This Technical Report is based on, and much of the material i
21、s from, Freeman and others 8 . It complements ISO 4373, Hydrometry Water level measuring devices. ISO/TR 23211:2009(E) vi ISO 2009 All rights reservedIntroduction Submersible pressure transducers, developed in the early 1960s, have made the collection of water-level and pressure data much more conve
22、nient than former methods. Submersible pressure transducers, when combined with electronic data recorders have made it possible to collect continuous or nearly continuous water-level or pressure data from wells, piezometers, soil-moisture tensiometers, and surface water gages. These more frequent me
23、asurements have led to an improved understanding of the hydraulic processes in streams, soils, and aquifers. TECHNICAL REPORT ISO/TR 23211:2009(E) ISO 2009 All rights reserved 1Hydrometry Measuring the water level in a well using automated pressure transducer methods 1 Scope This Technical Report pr
24、ovides information about the functional requirements of instrumentation for measuring the water level in a well using automated pressure transducer methods. This Technical Report provides guidance for the proper selection, installation and operation of submersible pressure transducers and data logge
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISOTR232112009HYDROMETRYMEASURINGTHEWATERLEVELINAWELLUSINGAUTOMATEDPRESSURETRANSDUCERMETHODS 液体 比重 测定法

链接地址:http://www.mydoc123.com/p-1257852.html