ISO IEC TR 13841-1995 Information technology - Guidance on measurement techniques for 90 mm optical disk cartridges《信息技术 90 mm盒式光盘测量技术导则》.pdf
《ISO IEC TR 13841-1995 Information technology - Guidance on measurement techniques for 90 mm optical disk cartridges《信息技术 90 mm盒式光盘测量技术导则》.pdf》由会员分享,可在线阅读,更多相关《ISO IEC TR 13841-1995 Information technology - Guidance on measurement techniques for 90 mm optical disk cartridges《信息技术 90 mm盒式光盘测量技术导则》.pdf(77页珍藏版)》请在麦多课文档分享上搜索。
1、TECHNICAL REPORT ISO/IEC TR 13841 First edition 1995-07-01 Information technology - Guidance on measurement techniques for 90 mm optical disk cartridges Technologies de /information - Lignes directrices pour /es techniques de mesurage des cartouches de disque optique de diamktre 90 mm q m , Referenc
2、e number lSO/IEC TR 13841 :I 995(E) ISO/IEC TR 13841:1995(E) Contents 1. General 1.1 Scope 1.2 Purpose 1.3 Reference 1.4 Definitions 2 Measurement environments 2.1 General 2.2 Measurement environment A 2.3 Measurement environments B 2.4 Measurement environment C 3 Measurement set up 3.1 General 3.2
3、Measurement accuracy 3.3 Calibration disk 3.4 Measurement area 3.5 Reference Servo 4 Items for measurement techniques 4.1 General 4.2 List of measurement items 5 Measurement techniques 5.1 Shutter opening force 5.1.1 Definition 5.1.2 Measurement procedure 5.2 Clamping force 5.2.1 Introduction 5.2.2
4、Measurement procedure 5.3 Tilt 5.3.1 Introduction 5.3.2 Measurement method 1 5.3.3 Measurement method 2 5.4 Axial and Radial acceleration 5.4.1 Introduction 5.4.2 Measurement system 5.4.3 Procedure 1: Low-pass measurement system 5.4.4 Procedure 2: High-pass Measurement System 5.4.5 Procedure 3: Tota
5、l measurement system 5.5 Reflectance 3 3 3 3 3 3 4 4 4 4 4 4 5 5 7 7 7 7 8 9 14 0 ISO/IEC 1995 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, witho
6、ut permission in writing from the publisher. ISO/IEC Copyright Office l Case postale 56 l CH-1211 Geneve 20 l Switzerland Printed in Switzerland ii 0 IS0 ISOfiEC TR 13841: 1995(E) 5.6 Capture cylinder 5.7 Signals from grooves 5.7.1 Measurement equipment 5.7.2 Measurement conditions 5.7.3 Measuring p
7、rocedure 5.8 Signals from headers 5.8.1 General 5.8.2 Amplitude measurement 5.9 Read power 5.9.1 Definition 5.9.2 Measurement conditions 5.9.3 Measuring procedure 5.9.4 Analysis 5.10 Write power and erase power 5.10.1 Definition 5.10.2 Measurement conditions 5.10.3 Measuring procedure 5.10.4 Analysi
8、s 5.11 Imbalance of the magneto-optical signal 5.11.1 Measurement condition 5.11.2 Measuring procedure 5.12 Narrow-Band Signal-to-Noise Ratio (NBSNR) 5.12.1 Definition 5.12.2 Measurement conditions 512.3 Measuring procedure Annexes A - The flow chart for determining write power and erase power B - A
9、veraging Times and Spectrum Analyzer Data C - Measurement Frequency Point for Noise Level D - Notes on Measuring Noise Level E - Example of measurement procedure of signals from grooves F - The Measuring Method of The Capture Cylinder Radius for the Hub G - Better noise measurement with the HP3585A
10、- type 2, when the subject is still under technical development or where for any other reason there is the future but not immediate possibility of an agreement on an International Standard; - type 3, when a technical committee has collected data of a different kind from that which is normally publis
11、hed as an International Standard (“state of the art”, for example). Technical Reports of types 1 and 2 are subject to review within three years of publication, to decide whether they can he transformed into International Standards. Technical Reports of type 3 do not necessarily have to be reviewed u
12、ntil the data they provide are considered to be no longer valid or useful. ISO/IEC TR 13841, which is a Technical Report of type 3, was prepared by Joint Technical Committee ISO/IEC JTC 1, Information technology. TECHNICAL REPORT 0 ISO/IEC ISO/IEC TR 13841:1995(E) Information technology - Guidance o
13、n measurement techniques for 90 mm optical disk cartridges 1 General 1.1 Scope This technical report provides Guidance on Measurement Techniques for 90 mm Rewritable/Read-only Optical Disk Cartridges. 1.2 Purpose This technical report provides guidance on measurement techniques which are not well un
14、derstood in industry. The basic concept of this report is to aid in the understanding of interchangeability between disks and drives. This report gives guidance and provides some examples of measurement techniques to aid this understanding. 13 Reference ISO/IEC 10090: 1992, Information technology -
15、90 mm optical disk cartridges, rewritable and read only, for data interchange. 1.4 Definitions The definitions of this report are the same as the definitions of ISO/IEC 10090. 2 Measurement environments 2.1 General This report recommends 3 kinds of measurement environments. Each clause in section 5
16、may use 1 of 3 measurement environments as specified in this section. Basically, Measurement environment A is used for each clause in section 5 unless noted. Additional environments or conditions are recommended in each clause. 2.2 Measurement environment A Measurement environment A is the same as t
17、he testing environment of ISO/IEC 10090 i.e. temperature : 23 “C*2 “C relative humidity : 45% to 55% atmospheric pressure : 60kPato 106kRa air cleanliness : Class 100 000 magnetic field strength : 32OOOA/mmax. 2.3 Measurement environments B Measurement environments B are used for the highest tempera
18、ture marginal test temperature : 50 “C P/T = 6*SD/Tolerance 0.2 where SD is the standard deviation and Tolerance is the upper limit minus the lower limit of the specification. For example: In the case of reflectance P/T = 6* SD/(0,29-0,14) 0,2 i.e. SD 0,005 In the case of single ended specifications
19、, the system should be capable of resolving the number of significant digits in the parameter specification. 3.3 Calibration disk The laser power of the optical drive and/or the measurement equipment on the recording layer can be calibrated from the calibration disk which is provided by the Reliabil
20、ity Center for Electronic Components of Japan (RCJ) Note - This calibration disk cartridge has been established by RCJ, l-l-2 Hachiman Higashikurume Tokyo. Japan, and can be ordered under Part number JCM6272 until 2002. 3.4 Measurement area ISO/IEC 10090 requires disks to satisfy specifications in a
21、ll the areas of the disk unless noted. (See annex R in ISO/IEC 10090). This report shows the most critical measurement areas in each clause, as follows: (A) Innermost diameter is critical (R=24mm) for Read power, NBSNR, Signal from headers (Ivfo , Idmax /Idmin), Push-pull signal and cross-track sign
22、al in ROM area (B) Correspond to control track data ( R=24mm, 30mm, 40mm) Write power, Erase power (C) Outermost diameter is critical (R=40mm) for Tilt, Axial and radial accelerations, (D) Outermost and innermost diameters are critical (R=24mm, 40mm) for Reflectance, Imbalance of the MO signal (E) I
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISOIECTR138411995INFORMATIONTECHNOLOGYGUIDANCEONMEASUREMENTTECHNIQUESFOR90MMOPTICALDISKCARTRIDGES 信息技术

链接地址:http://www.mydoc123.com/p-1257389.html