ISO 9096-2003 Stationary source emissions - Manual determination of mass concentration of particulate matter《固定源排放 颗粒物质量浓度的手动测定》.pdf
《ISO 9096-2003 Stationary source emissions - Manual determination of mass concentration of particulate matter《固定源排放 颗粒物质量浓度的手动测定》.pdf》由会员分享,可在线阅读,更多相关《ISO 9096-2003 Stationary source emissions - Manual determination of mass concentration of particulate matter《固定源排放 颗粒物质量浓度的手动测定》.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference numberISO 9096:2003(E)ISO 2003INTERNATIONAL STANDARD ISO9096Second edition2003-02-01Stationary source emissions Manual determination of mass concentration of particulate matter missions de sources fixes Dtermination manuelle de la concentration en masse de poussires Copyright Internationa
2、l Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ISO 9096:2003(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be print
3、ed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no lia
4、bility in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is
5、suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. ISO 2003 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
6、 any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-ma
7、il copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2003 All rights reservedCopyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ISO 9096:2003(E) ISO 2003 All
8、rights reserved iiiContents Page Foreword iv Introduction v 1 Scope 1 2 Normative references . 1 3 Terms and definitions. 1 4 Principle . 4 4.1 General. 4 4.2 Interferences 5 5 Sampling plane and sampling points . 5 5.1 General. 5 5.2 Sampling plane 6 5.3 Requirements for sampling points 6 5.4 Minim
9、um number and location of sampling points. 6 5.5 Access ports 7 5.6 Sampling time 7 6 Apparatus and materials 8 6.1 Gas velocity, temperature, pressure, and gas composition measurement devices 8 6.2 Sampling equipment. 8 6.3 Equipment for particulate matter recovery 14 6.4 Equipment for conditioning
10、 and weighing. 14 7 Sampling and weighing procedures . 15 7.1 General aspects 15 7.2 Weighing procedure . 16 7.3 Sampling 18 7.4 Validation of results 21 8 Additional aspects 22 8.1 Thermal behaviour of particulate matter 22 8.2 Particulate deposits upstream of the filter. 24 8.3 Improvement of the
11、weighing procedure . 24 9 Calculations. 24 9.1 Isokinetic flowrate. 24 9.2 Dust concentration . 25 10 Performance characteristics 26 10.1 General aspects 26 10.2 Experimental data for sampling 27 11 Test report . 27 Annex A (normative) Proven design of the entry nozzle 29 Annex B (normative) Determi
12、nation of positions of sampling points in circular and retangular ducts. 30 Annex C (informative) Examples of weighing bias . 34 Annex D (informative) Isokinetic sampling conditions. 36 Annex E (informative) Summary validation information 38 Annex F (informative) Examples of suitable access ports fo
13、r sampling equipment. 41 Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ISO 9096:2003(E) iv ISO 2003 All rights reservedForeword ISO (the International Organization for
14、Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the r
15、ight to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Internation
16、al Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as
17、 an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. IS
18、O 9096 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 1, Stationary source emissions. This second edition cancels and replaces the first edition (ISO 9096:1992), which has been technically revised. Copyright International Organization for Standardization Provided by IHS
19、 under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ISO 9096:2003(E) ISO 2003 All rights reserved vIntroduction Close liaison and cooperation between ISO/TC 146/SC 1 and CEN/TC 264 has resulted in the preparation of this International Standard (I
20、SO 9096), ISO 12141 and European Standard EN 13824-1. This International Standard is similar to EN 13284-1 with additional emphasis given on the use of high-volume sampling techniques. A representative, integrated sample is extracted from the flue gas and particulate matter entrained in the gas samp
21、le is separated by a filter. The pre-weighed filter is subsequently dried and weighed. A relative increase in the mass is attributed to the collection of particulate matter on the filter. To meet the specifications of this International Standard, the particulate sample must be weighed to a specified
22、 level of accuracy. This level of accuracy is achieved by: a) exercising extreme care in weighing, in accordance with the procedures of this International Standard; b) extending the sampling time at conventional sampling rates; c) sampling at higher rates for conventional sampling times (high-volume
23、 sampling); d) recovering all dust upstream of the filter. Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright International Organization for Standardization Provid
24、ed by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-INTERNATIONAL STANDARD ISO 9096:2003(E) ISO 2003 All rights reserved 1Stationary source emissions Manual determination of mass concentration of particulate matter 1 Scope This Internati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO90962003STATIONARYSOURCEEMISSIONSMANUALDETERMINATIONOFMASSCONCENTRATIONOFPARTICULATEMATTER 固定 排放 颗粒

链接地址:http://www.mydoc123.com/p-1256281.html