ISO 9088-1997 Carbonaceous materials used for the production of aluminium - Cathode blocks an prebacked anodes - Determination of the density in xylene by a pyk.pdf
《ISO 9088-1997 Carbonaceous materials used for the production of aluminium - Cathode blocks an prebacked anodes - Determination of the density in xylene by a pyk.pdf》由会员分享,可在线阅读,更多相关《ISO 9088-1997 Carbonaceous materials used for the production of aluminium - Cathode blocks an prebacked anodes - Determination of the density in xylene by a pyk.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL STANDARD First edition 1997-03-01 Carbonaceous materials used for the production of aluminium - Cathode blocks and prebacked anodes - Determination of the density in xylene by a pyknometric method Produits carbon a=400net; p=iso; o=isocs; s=central Printed in Switzerland ii INTERNATION
2、AL STANDARD o Iso IS0 9088:1997(E) Carbonaceous materials used for the production of aluminium - Cathode blocks and prebaked anodes - Detemination of the density in xylene by pyknometric method 1 Scope This International Standard specifies a pyknometric method for the determination of the true densi
3、ty in xylene of cathode blocks and prebacked anodes used for the production of aluminium. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated
4、were valid. All standards are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and IS0 maintain registers of currently valid Internat
5、ional Standards. IS0 3507: 1976, Pyknometers. IS0 8007: 1985, Carbonaceous materials used in the production of aluminium - Sampling from cathodic blocks and prebaked anodes - General. 3 Principle The true density of cathode blocks and prebaked anodes is measured in xylene in a pyknometer after degas
6、sing under a vacuum. 4 Reagents and materials During the determination, unless otherwise stated, use only reagents of recognized analytical grade and only distilled water, or water of equivalent purity, degassed by boiling for 1 h. 4.1 Ethanol, 95 % (V/V). 4.2 Acetone. 4.3 Sulfuric acid, density app
7、rox. I,84 g/ml, about 98 % (m/m) solution. 1 ISO9088:1997(E) IS0 4.4 Xylene, commercial grade, density about 0,86 g/ml. WARNING - Xylene burns the skin and can also be absorbed into the system through the skin. In addition, inhalation of the vapour from hot material is to be avoided. 5 Apparatus 5.1
8、 Pyknometer, type 3 as defined in IS0 3507 (Gay-Lussac), capacity 25 ml. 5.2 Degassing apparatus (see figure I), comprising the following items: 52.1 Container (1) for the pyknometer, consisting of a glass beaker (2) with removable lid (3) and O-ring (4), capable of containing the pyknometer without
9、 its stopper. The container outlet (5) is connected to a pump (not shown). + 5.2.2 Filling device (6), fitted to the container by a ground-glass joint (7). A tube (8) extends down into the pyknometer. A reservoir (9) with a ground-glass stopper (10) contains the pyknometer liquid which is allowed to
10、 flow into the pyknometer through a teflon valve (11). 5.2.3 Stand (12), to support the beaker when no vacuum is applied to the degassing apparatus. A rod (13) with a spring (14) allows the beaker (Z),with the pyknometer in it, to be shaken to facilitate the evolution of a gas bubbles during degassi
11、ng. The apparatus is made of glass. A rotary pump is connected to the outlet of the apparatus via an oil trap (15). A manometer (16) is connected to the vacuum system between the pump and the oil trap. The vacuum is adjusted so that the manometer, which is about 600 mm from the joint (7) between the
12、 container and the filling device, registers I,3 kPa + 0,3 kPa. A valve (17) is fitted to allow air back into the apparatus. This has to be done slowly and with due care. NOTE - At a pressure of I,3 kPa + 0,3 kPa and an ambient temperature of 25 OC, slight vapourization of xylene may occur until equ
13、ilibrium is reached, but this is of no consequence. The apparatus described above is only an example; other apparatus with the same characteristics may be used. 5.3 Drying oven, capable of being maintained at 120 “C + 2 “C. 5.4 Thermostatically controlled bath, capable of being maintained at 25 “C k
14、 0,05 OC. 5.5 Grinder, capable of grinding the sample to a particle size of less than 63 pm. The parts which come into contact with the sample shall be made of hardmetal to avoid contamination. 5.6 Filter paper. 5.7 Jaw-type crusher. 6 Sampling Sample in accordance with IS0 8007. 2 IS0 9088:1997(E)
15、Dimensions in millimetres Volume 50 ml I) Container 2) Glass beaker 3) Lid 4) O-ring 5) Outlet 6) Filling device 7) Ground-glass joint 8) Tube 9) Reservoir Voiume 330 ml 10) 11) 12) 13) 14) 15) 16) 17) Ground-glass stopper Teflon valve Stand Rod Spring Oil trap Manometer Valve -12 Figure 1 - Typical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO90881997CARBONACEOUSMATERIALSUSEDFORTHEPRODUCTIONOFALUMINIUMCATHODEBLOCKSANPREBACKEDANODESDETERMINATIONOFTHEDENSITYINXYLENEBYAPYKPDF

链接地址:http://www.mydoc123.com/p-1256275.html