1、 STD-IS0 8858-1-ENGL 1770 I 4851903 0878733 078 INTERNATIONAL STANDARD IS0 8858-1 :1990 TECHNICAL CORRIGENDUM 1 Published 2001 -04-01 INTERNATIONAL ORGANIZATION FOR STANDARDIZATION MDKCIYHAPOflHAR OPrA”3Al collecting agent: A reagent added to a pulp to bring about adhesion between solid parti- cles
2、and air bubbles. 3.2 flotation concentrate: The clean product recov- ered in froth flotation. 3.3 conditioning: The preparatory stage in the flotation process in which the reagents are brought into intimate contact with the solids of the pulp. 3.4 frother; frothing agent: A reagent used to con- trol
3、 the size and stability of the air bubbles in the flotation process. 3.5 froth flotation: A process for cleaning fine coal in which the coal, with the aid of a reagent or rea- gents, becomes attached to air bubbles in a liquid medium and floats as a froth. 3.6 pulp: A mixture of solid particles and
4、water. 1 IS0 BB58 PT*I 90 IS0 8858-1:1990(E) 3.7 flotation tailings: The reject from froth flotation cells. 4 Principle Mixing of a coal sample with water to form a sus- pension in the flotation cell. Addition of collector and frother and introduction of air. Separate recovery of the concentrate and
5、 tailings and determination of the yield and ash of each. NOTE 1 the flotation characteristics of the coal. The use of chemical additives or heat can affect 5 Reagents During the analysis, use only reagents of recognized analytical grade and only distilled water or water of equ va lent purity. 5.1 C
6、ollector, n-Dodecane. 5.2 Frother, Methyl so-butyl carbinol (MIBC), (4-MethyIpentan-2-01), 0,14 YO (V/V) aqueous sol- ution. 6 Apparatus The apparatus shall be a mechanical impeller type flotation machine (see figure 1) with the following specifications. 6.1 Flotation cell, manufactured from stainle
7、ss steel. Figure 2 shows the dimensions of the flotation cell. The capacity of the cell with the deflector block and impeller in place is approximately 3,5 litres. It has been shown that the results obtained from laboratory froth flotation tests are very dependent on the procedure used to remove the
8、 concentrate from the surface of the pulp. For this reason, a de- flector block manufactured from plastics material (see figure3) is used to guide the concentrate to a rectangular area in front of the impeller housing. The concentrate can then be removed by means of a scraper (see figure4) which is
9、designed to cover the full width of the cell to a constant depth. In order to establish the volume of pulp which can be contained in the flotation cell, the deflector block is fitted into the cell and water is added to the flotation cell to about 20 mm to 30 mm below the required pulp level. The imp
10、eller is started (air valve off) and additional water is added to the required mark (see 8.4). The impeller is stopped, the deflector block removed, and the volume of water in the flotation cell is measured. 2 Li851903 0095878 7 6.2 Impeller assembly, of stainless steel and capa- ble of rotation at
11、frequencies up to 1500 rev/min (equivalent to a speed of 5,7 m/s at the periphery). The dimensions of the impeller and diffuser are shown in figures 5 and 6. The lower face of the impeller shall be positioned no more than 5 mm from the base of the cell. NOTE 2 Impellers constructed of other material
12、s may be used, provided that it can be shown that the charac- teristics of flotation for the cell are similar to those ob- tained when a stainless steel impeller is used. To achieve this, different impeller rotational frequencies may be used if necessary. 6.3 Constant level control, maintaining the
13、level of the pulp in the cell during the flotation test. 6.4 Scraper, of the design shown in figure4. Its clearance at the sides of the cell shall be minimal and should not exceed 2 mm. The scraper shall be of such dimensions that it clears the pulp level (as defined in 8.4) by not more than 2 mm. 6
14、.5 Calibrated micro-syringe, for the addition of the collector (5.1). 6.6 Pipette, of capacity 25 ml, complying with IS0 648, for the addition of the frother solution (5.2). 6.7 Timlng device, accurate to 1 s and capable of being zeroed and started as required. 6.8 Test sieves, complying with IS0 56
15、5, for the particle size analysis of the feed. 7 Sampling The history and method of preparation of samples can affect considerably the flotation characteristics of the coal. The origin of the sample should be re- corded and care should be taken to ensure that samples for comparison purposes are prep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO885811990HARDCOALFROTHFLOTATIONTESTINGPART1LABORATORYPROCEDURE 硬煤 泡沫 浮选 试验 部分 实验室 程序 PDF

链接地址:http://www.mydoc123.com/p-1256166.html