1、 ISO 2016 Fire resistance tests Part 3: Door and shutter assemblies horizontally oriented Essais de rsistance au feu Partie 3: Assemblages de portes et volets orients horizontalement INTERNATIONAL STANDARD ISO 3008-3 First edition 2016-05-01 Reference number ISO 3008-3:2016(E) ISO 3008-3:2016(E)ii I
2、SO 2016 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2016, Published in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting o
3、n the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Ch. de Blandonnet 8 CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22
4、 749 09 47 copyrightiso.org www.iso.org ISO 3008-3:2016(E)Foreword v Introduction vi 1 Scope . 1 2 Normative references 1 3 T erms and definitions . 1 4 Test equipment. 2 5 Test conditions . 2 6 Test specimen 2 6.1 Size of specimen . 2 6.2 Design of specimen 2 6.3 Verification . 3 7 Installation of
5、test specimen 3 7.1 General . 3 7.2 Supporting construction . 3 7.3 Test construction . 3 7.3.1 Associated and supporting construction 3 7.3.2 Associated construction 4 7.3.3 Supporting construction . 4 7.4 Gaps 4 8 Conditioning 4 8.1 Moisture content . 4 8.2 Mechanical 4 9 Application of instrument
6、ation 4 9.1 Temperature measurements . 4 9.1.1 Furnace temperature measuring instrument . 4 9.1.2 Unexposed face thermocouples 5 9.2 Maximum temperature 6 9.3 Pressure measurements . 6 9.4 Heat flux measurement . 6 9.4.1 General 6 9.4.2 Apparatus . 7 9.4.3 Procedure . 7 9.4.4 Measurement 8 9.5 Loadi
7、ng 8 9.6 Deflection . 8 10 Test procedure 8 10.1 Gap measurements 9 10.2 Test Measurements . 9 11 Performance criteria 9 11.1 Integrity 9 11.2 Insulation . 9 11.3 Loadbearing capacity 9 12 Test report 10 13 Field of direct application of test results10 13.1 General 10 13.2 Timber constructions .11 1
8、3.3 Steel constructions .11 13.4 Glazed constructions 11 13.5 Fixings/hardware 11 ISO 2016 All rights reserved iii Contents Page ISO 3008-3:2016(E)Annex A (normative) Conditioning requirements for supporting constructions .13 Annex B (informative) Estimation of r adiant heat flux using measur ed sur
9、fac e t emper atur e and Stefan-Boltzmann law .14 iv ISO 2016 All rights reserved ISO 3008-3:2016(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally
10、 carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the w
11、ork. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the di
12、fferent approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document
13、 may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/pa
14、tents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO prin
15、ciples in the Technical Barriers to Trade (TBT), see the following URL: Foreword Supplementary information. The committee responsible for this document is ISO/TC 92, Fire safety, Subcommittee SC 2, Fire containment. ISO 3008 consists of the following parts, under the general title, Fire resistance t
16、ests: Part 2: Lift landing door assemblies Part 3: Door and shutter assemblies horizontally oriented ISO 2016 All rights reserved v ISO 3008-3:2016(E) Introduction This part of ISO 3008 specifies requirements for fire resistance testing which are unique to the elements of building construction descr
17、ibed as horizontally oriented doors and shutters. The requirements for these doors and shutters are intended to be applied in conjunction with the appropriate detailed and general requirements contained in ISO 834-1 and ISO 3008.vi ISO 2016 All rights reserved Fire resistance tests Part 3: Door and
18、shutter assemblies horizontally oriented CAUTION The attention of all persons concerned with managing and carrying out this f i r e - r e s i s t a n c e t e s t i s d r a w n t o t h e f a c t t h a t f i r e t e s t i n g m a y b e h a z a r d o u s a n d t h a t t h e r e i s a possibility that t
19、oxic and/or harmful smoke and gases may be evolved during the test. Mechanical and operational hazards may also arise during the construction of test elements or structures, their testing and disposal of test residues. An assessment of all potential hazards and health risks shall be made by the labo
20、ratory and safety precautions shall be identified and provided. Written safety instructions shall be issued. Appropriate training shall be given to relevant personnel. Laboratory personnel shall ensure that they follow written safety instructions at all times. 1 Scope This part of ISO 3008 specifies
21、 the test method for determining the fire resistance of horizontally oriented door and shutter assemblies which may be exposed to a fire from the underside. It is applicable to all types of door and shutter assemblies installed in a horizontal orientation within floor or roof assemblies requiring fi
22、re-resistance ratings in buildings. The test method allows for the measurement of integrity and, if required, the measurement of radiation and thermal insulation. In addition, this test method includes measurement of the load-carrying ability of the test specimens subjected to a standard fire-resist
23、ance test. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includin
24、g any amendments) applies. ISO 834-1:1999, Fire-resistance tests Elements of building construction Part 1: General requirements ISO 834-5, Fire-resistance tests Elements of building construction Part 5: Specific requirements for loadbearing horizontal separating elements ISO 3008, Fire-resistance te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO300832016FIRERESISTANCETESTSPART3DOORANDSHUTTERASSEMBLIESHORIZONTALLYORIENTED 耐火 试验 部分 百叶窗 水平 定向 组件

链接地址:http://www.mydoc123.com/p-1253198.html