ISO 20492-2-2008 Glass in buildings - Insulating glass - Part 2 Chemical fogging tests《建筑玻璃材料 保温玻璃 第2部分 化学雾化实验》.pdf
《ISO 20492-2-2008 Glass in buildings - Insulating glass - Part 2 Chemical fogging tests《建筑玻璃材料 保温玻璃 第2部分 化学雾化实验》.pdf》由会员分享,可在线阅读,更多相关《ISO 20492-2-2008 Glass in buildings - Insulating glass - Part 2 Chemical fogging tests《建筑玻璃材料 保温玻璃 第2部分 化学雾化实验》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference number ISO 20492-2:2008(E) ISO 2008INTERNATIONAL STANDARD ISO 20492-2 First edition 2008-10-01 Glass in buildings Insulating glass Part 2: Chemical fogging tests Verre dans la construction Verre isolant Partie 2: Essais dembuage chimique ISO 20492-2:2008(E) PDF disclaimer This PDF file ma
2、y contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the resp
3、onsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creati
4、on parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2008
5、 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the count
6、ry of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2008 All rights reservedISO 20492-2:2008(E) ISO 2008 All rights reserved iiiContents Page Foreword iv Intro
7、duction.v 1 Scope1 2 Normative references1 3 Terms and definitions .1 4 Requirements.2 5 Test methods .2 6 Test report8 Bibliography13 ISO 20492-2:2008(E) iv ISO 2008 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards
8、bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizat
9、ions, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in th
10、e ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of
11、the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 20492-2 was prepared by Technical Committee ISO/TC 160, Glass i
12、n building, Subcommittee SC 1, Product considerations. ISO 20492 consists of the following parts, under the general title Glass in buildings Insulating glass: Part 1: Durability of edge seals by climate tests Part 2: Chemical fogging tests Part 3: Gas concentration and gas leakage Part 4: Test metho
13、ds for the physical attributes of edge seals ISO 20492-2:2008(E) ISO 2008 All rights reserved vIntroduction This part of ISO 20492 consists of a series of procedures for testing the performance of pre-assembled, permanently sealed insulating glass units or insulating glass units with capillary tubes
14、 that have been intentionally left open. This part of ISO 20492 is intended to help ensure that energy savings are made, as the U-value and solar factor (solar heat gain coefficient) do not change significantly; health is preserved, because sound-reduction and vision do not change significantly; saf
15、ety is provided because mechanical resistance does not change significantly. This part of ISO 20492 also covers additional characteristics that are important to the trade, and marking of the product (i.e. CE marking or other regulatory groups) is also included. There are distinct markets to be consi
16、dered for insulating glass. As within each market there are technical differences with respect to rebate sizes, vision lines and methods of application, two approaches are included in this part of ISO 20492. Approach 1 addresses requirements for markets such as North America. Approach 2 addresses re
17、quirements for markets such as Europe. Each approach includes separate test methods and specifications pertaining to minimum requirements for the durability of edge seals by climate tests. This part of ISO 20492 does not cover the physical requirements of sealed glass insulating units such as appear
18、ance, thermo-physical properties, heat and light transmission and glass displacement. The main intended uses of the insulating glass units are installations in buildings and constructions such as in windows, doors, curtain walling, skylights, roofs and partitions where protection against direct ultr
19、aviolet radiation exists at the edges. NOTE In cases where there is no protection against direct ultraviolet radiation at the edges, such as structural- sealant glazing systems, it is still necessary to review factors such as sealant longevity when exposed to long-term ultraviolet light and the stru
20、ctural properties of the sealant for these applications. For more information on the requirements for structural sealant glazing applications, reference can be made to ASTM C13691 , ASTM C12492and ASTM C12653 . The test methods in this part of ISO 20492 are intended to provide a means for testing th
21、e performance of the sealing system and construction of sealed insulating glass units. Sealed, insulating glass units tested in accordance with these methods are not intended for long-term immersion in water. The options for testing apply only to sealed, insulating glass units that are constructed w
22、ith glass. The methods of this part of ISO 20492 might not be applicable in certain cases, such as insulating glass units containing spandrel glass or absorptive coatings, as these products can experience field temperatures that exceed the temperature limitations of the sealant. INTERNATIONAL STANDA
23、RD ISO 20492-2:2008(E) ISO 2008 All rights reserved 1Glass in buildings Insulating glass Part 2: Chemical fogging tests 1 Scope This part of ISO 20492 establishes two methods for testing the resistance to fogging of pre-assembled, permanently sealed insulating glass units or insulating glass units w
24、ith capillary tubes intentionally left open. The two methods are designated as Approach 1 for markets such as North America, and Approach 2 for markets such as Europe. This part of ISO 20492 is not applicable to sealed, insulating glass units containing a spandrel glass coating due to testing limita
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO2049222008GLASSINBUILDINGSINSULATINGGLASSPART2CHEMICALFOGGINGTESTS 建筑 玻璃 材料 保温 部分 化学 雾化 实验 PDF

链接地址:http://www.mydoc123.com/p-1252250.html