ISO 16895-2016 Wood-based panels - Dry-process fibreboard《木基板材 干燥处理的纤维板》.pdf
《ISO 16895-2016 Wood-based panels - Dry-process fibreboard《木基板材 干燥处理的纤维板》.pdf》由会员分享,可在线阅读,更多相关《ISO 16895-2016 Wood-based panels - Dry-process fibreboard《木基板材 干燥处理的纤维板》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2016 Wood-based panels Dry-process fibr eboar d Panneaux base de bois Panneaux de fibres obtenus par procd sec INTERNATIONAL STANDARD ISO 16895 First edition 2016-02-01 Reference number ISO 16895:2016(E) ISO 16895:2016(E)ii ISO 2016 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2016, Pub
2、lished in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permi
3、ssion can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Ch. de Blandonnet 8 CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22 749 09 47 copyrightiso.org www.iso.org ISO 16895:2016(E)Foreword v 1
4、Scope . 1 2 Normati v e r efer enc es 1 3 T erms and definitions . 2 4 S ymbols and abbr e viat ed t erms . 2 5 Classification, designation and c oding 3 5.1 General . 3 5.1.1 Classification matrices 3 5.1.2 Uses . 3 5.1.3 Additional classifications 3 5.1.4 Structural grades . 4 5.2 Ultra-low-densit
5、y fibreboard (UDF) . 4 5.3 Low-density fibreboard (LDF). 4 5.4 Medium density fibreboard (MDF) . 4 5.5 High-density fibreboard (HDF) . 5 6 T ests r elat ed to each gr ade 5 6.1 Mandatory tests . 5 6.2 Optional tests . 6 7 Thickness r anges 8 8 Expr ession of specification limits and gener al r equir
6、 ements 8 8.1 Expression of specification limits . 8 8.2 Lower specification limits . 8 8.3 Upper specification limits 9 8.4 Moisture resistance requirement options . 9 8.5 Density variation, dimension and moisture content requirements 9 8.6 Formaldehyde requirements .10 8.7 Load bearing fibreboard
7、10 9 Specific pr operty r equir ements for ultr a-lo w -density fibr eboar d (UDF -FN RE G) 10 10 Specific pr operty r equir ements for lo w -density fibr eboar d .11 10.1 General 11 10.2 Requirements for furniture grade low-density fibreboard for use in dry conditions (LDF-FN REG) 11 10.3 Requireme
8、nts for building grade low-density fibreboard for use in dry conditions (LDF-BL REG) 11 10.4 Requirements for general purpose low-density fibreboard for use in temperate humid conditions (LDF-GP MR1) .12 10.5 Requirements for furniture grade low-density fibreboard for use in temperate humid conditio
9、ns (LDF-FN MR1) .12 10.6 Requirements for building grade low-density fibreboard for use in temperate humid conditions (LDF-BL MR1) .13 10.7 Requirements for general purpose low-density fibreboard for use in tropical humid conditions (LDF-GP MR2) .13 10.8 Requirements for furniture grade low-density
10、fibreboard for use in tropical humid conditions (LDF-FN MR2) 14 11 Specific pr operty r equir ements for medium-density fibr eboar d 14 11.1 General 14 11.2 Requirements for general purpose medium-density fibreboard for use in dry conditions (MDF-GP REG) 15 11.3 Requirements for furniture grade medi
11、um-density fibreboard for use in dry conditions (MDF-FN REG) 15 ISO 2016 All rights reserved iii Contents Page ISO 16895:2016(E)11.4 Requirements for building grade medium-density fibreboard for use in dry conditions (MDF-BL REG) 15 11.5 Requirements for load bearing medium-density fibreboard for us
12、e in dry conditions (MDF-LB REG) 16 11.6 Requirements for general purpose medium-density fibreboard for use in temperate humid conditions (MDF-GP MR1) 16 11.7 Requirements for furniture grade medium-density fibreboard for use in temperate humid conditions (MDF-FN MR1) .17 11.8 Requirements for build
13、ing grade medium-density fibreboard for use in temperate humid conditions (MDF-BL MR1) .18 11.9 Requirements for load bearing medium-density fibreboard for use in temperate humid conditions (MDF-LB MR1) .18 11.10 Requirements for general purpose medium-density fibreboard for use in tropical humid co
14、nditions (MDF-GP MR2) .19 11.11 Requirements for furniture grade medium-density fibreboard for use in tropical humid conditions (MDF-FN MR2) .20 11.12 Requirements for building grade medium-density fibreboard for use in tropical humid conditions (MDF-BL MR2) .21 11.13 Requirements for load bearing m
15、edium-density fibreboard for use in tropical humid conditions (MDF-LB MR2) .21 11.14 Requirements for fitments grade medium-density fibreboard for use in high humid conditions (MDF-FN HMR) 22 11.15 Requirements for building grade medium-density fibreboard for use in high humid conditions (MDF-BL HMR
16、) .23 12 Specific pr operty r equir ements for hig h-density fibr eboar d .23 12.1 General 23 12.2 Requirements for general purpose high-density fibreboard for use in dry conditions (HDF-GP REG) .24 12.3 Requirements for building grade high-density fibreboard for use in dry conditions (HDF-BL REG) .
17、24 12.4 Requirements for general purpose high-density fibreboard for use in temperate humid conditions (HDF-GP MR1) 24 12.5 Requirements for building grade high-density fibreboard for use in temperate humid conditions (HDF-BL MR1) 25 12.6 Requirements for general purpose high-density fibreboard for
18、use in high humid conditions (HDF-GP MR2) 25 12.7 Requirements for building grade high-density fibreboard for use in tropical humid conditions (HDF-BL MR2) 26 13 Mar king .26 Annex A (normative) Calculation of 5-per c entile and 95-per c entile v alues 28 iv ISO 2016 All rights reserved ISO 16895:20
19、16(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for whi
20、ch a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all m
21、atters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This
22、 document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or
23、all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users
24、and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO168952016WOODBASEDPANELSDRYPROCESSFIBREBOARD 板材 干燥 处理 纤维板 PDF

链接地址:http://www.mydoc123.com/p-1251695.html