ISO 16507-2013 Timber structures - Uniform concentrated static and concentrated impact loads on wood-based roof and floor panel assemblies - Test methods《木结构 木基.pdf
《ISO 16507-2013 Timber structures - Uniform concentrated static and concentrated impact loads on wood-based roof and floor panel assemblies - Test methods《木结构 木基.pdf》由会员分享,可在线阅读,更多相关《ISO 16507-2013 Timber structures - Uniform concentrated static and concentrated impact loads on wood-based roof and floor panel assemblies - Test methods《木结构 木基.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2013 Timber structures Uniform, concentrated static and concentrated impact loads on wood-based roof and floor panel assemblies Test methods Structures en bois Assemblages de panneaux en bois pour toitures et planchers sous charges concentres et rparties, statique et par impact Mthodes dessais
2、INTERNATIONAL STANDARD ISO 16507 First edition 2013-09-01 Reference number ISO 16507:2013(E) ISO 16507:2013(E)ii ISO 2013 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2013 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in
3、any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case pos
4、tale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ISO 16507:2013(E) ISO 2013 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references 1 3 Terms and definitions . 1 4 Symbo
5、ls 2 5 Specimen conditioning. 2 5.1 Dry . 2 5.2 Wet . 2 5.3 Redried . 2 6 Concentrated static load test . 2 6.1 Apparatus 2 6.2 Specimen preparation 4 6.3 Procedure 7 6.4 Report . 7 7 Concentrated impact load test . 8 7.1 Apparatus 8 7.2 Specimen preparation .11 7.3 Procedure .11 7.4 Report 13 8 Uni
6、formly distributed load test .14 8.1 General 14 8.2 Apparatus .14 8.3 Specimen preparation .15 8.4 Test procedure 16 8.5 Report 17 Annex A (informative) Structural performance requirements for span rating 18 Bibliography .22 ISO 16507:2013(E) Foreword ISO (the International Organization for Standard
7、ization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to
8、be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used
9、 to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of
10、 the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified
11、 during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on t
12、he meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information The committee responsible for this document is ISO
13、/TC 165, Timber structures.iv ISO 2013 All rights reserved ISO 16507:2013(E) Introduction During construction and occupancy of a building, floor and roof sheathing are subjected to uniform and concentrated static and impact loads that frequently govern the thickness required. Static loads may simula
14、te either foot traffic, or loads from fixtures, when applied through loading disks of appropriate size. Impact loads will occur during construction and also in service. Uniform loads may simulate snow, wind, or occupancy loads. Roof sheathing and subflooring are likely to be critical in strength or
15、stiffness, or both, under foot traffic and construction loads, while single-layer floors are generally critical under fixture loads, foot traffic, and in-service impact loads. Subfloors, like single floors, must also support fixture loads, but they will have an additional layer of material, such as
16、underlayment above, which will help to distribute concentrated loads. The procedures outlined will provide data that can be used to evaluate the structural performance, under concentrated and uniform loads, of roof and floor sheathing, separate from the effects of the framing, under simulated condit
17、ions representative of those in actual service. The concentrated static and impact test procedures are based upon ASTM E661-03 5 . The uniformly distributed load test is based upon NIST Voluntary Product Standard PS 1-09 3 . Annex A contains non-mandatory sampling and product performance guidelines
18、that correspond to span rating categories found in PS 1, PS 2, and CSA O325. These three structrural wood-based panel standards have been referenced in North American building codes for several decades. Over this period of time, the performance guidelines established in these standards have resulted
19、 in reliable and satisfactory in- service structural performance. ISO 2013 All rights reserved v Timber structures Uniform, concentrated static and concentrated impact loads on wood-based roof and floor panel assemblies Test methods 1 Scope This International Standard is applicable to determining th
20、e resistance to deflection and damage of wood- based panels subjected to concentrated impact loads from nonrigid blunt objects, concentrated static loads, and uniformly distributed loads. Surface indentation is not evaluated separately from deflection. The procedures are intended to simulate loading
21、 on roof or floor sheathing materials installed directly to framing. Three applications are covered: roof sheathing, subfloors, and single floors. Panels are tested parallel and/or perpendicular to the panel strength axis. Roof sheathing is tested in both a dry and a wet condition, while subfloors a
22、nd single floors are both tested in a dry condition, as well as a condition of having dried out after being wet. These moisture conditions are those commonly experienced with site-built construction. These procedures do not cover vibration and are not intended for the evaluation of the framed assemb
23、ly as a whole. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (incl
24、uding any amendments) applies. None. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 subfloor panel that provides the structural integrity of the floor and is directly fastened to the floor framing, in conventional timber framing 3.2 underlay
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO165072013TIMBERSTRUCTURESUNIFORMCONCENTRATEDSTATICANDCONCENTRATEDIMPACTLOADSONWOODBASEDROOFANDFLOORPANELASSEMBLIESTESTMETHODS

链接地址:http://www.mydoc123.com/p-1251594.html