ISO 16293-2-2017 Glass in building - Basic soda lime silicate glass products - Part 2 Float glass《建筑用玻璃 基本钠钙硅酸盐玻璃制品 第2部分 浮法玻璃》.pdf
《ISO 16293-2-2017 Glass in building - Basic soda lime silicate glass products - Part 2 Float glass《建筑用玻璃 基本钠钙硅酸盐玻璃制品 第2部分 浮法玻璃》.pdf》由会员分享,可在线阅读,更多相关《ISO 16293-2-2017 Glass in building - Basic soda lime silicate glass products - Part 2 Float glass《建筑用玻璃 基本钠钙硅酸盐玻璃制品 第2部分 浮法玻璃》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2017 Glass in building Basic soda lime silicate glass products Part 2: Float glass Verre dans la construction Verre de silicate sodocalcique Partie 2: Glace INTERNATIONAL STANDARD ISO 16293-2 First edition 2017-03 Reference number ISO 16293-2:2017(E) ISO 16293-2:2017(E)ii ISO 2017 All rights re
2、served COPYRIGHT PROTECTED DOCUMENT ISO 2017, Published in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an
3、intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Ch. de Blandonnet 8 CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22 749 09 47 copyrighti
4、so.org www.iso.org ISO 16293-2:2017(E)Foreword iv 1 Scope . 1 2 Normative references 1 3 T erms and definitions . 1 4 Dimensional requirements . 3 4.1 Thickness . 3 4.1.1 General 3 4.1.2 Tolerances 3 4.2 Length, width and squareness . 4 4.2.1 Jumbo and split sizes 4 4.2.2 Supplied and final cut size
5、s 4 5 Quality requirements 5 5.1 General . 5 5.2 Methods of observation and measurement . 5 5.2.1 Optical faults 5 5.2.2 Visual faults 6 5.2.3 Edge defects for final cut sizes . 7 5.3 Acceptance levels 8 5.3.1 Optical faults 8 5.3.2 Spot faults 8 5.3.3 Linear/extended faults . 8 5.3.4 Edge defects f
6、or final cut sizes . 9 6 Designation 9 Annex A (informative) Method for measuring the halo size of spot fault .10 Bibliography .12 ISO 2017 All rights reserved iii Contents Page ISO 16293-2:2017(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of nationa
7、l standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. Internation
8、al organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended
9、for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www .iso
10、 .org/ directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document wi
11、ll be in the Introduction and/or on the ISO list of patent declarations received (see www .iso .org/ patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on the voluntary nature of standards, the m
12、eaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following URL: w w w . i s o .org/ iso/ foreword .html. The committee responsib
13、le for this document is ISO/TC 160, Glass in building, Subcommittee SC 1, Product considerations. A list of all parts in the ISO 16293 series can be found on the ISO website.iv ISO 2017 All rights reserved INTERNATIONAL ST ANDARD ISO 16293-2:2017(E) Glass in building Basic soda lime silicate glass p
14、roducts Part 2: Float glass 1 Scope This document specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass for use in building, as defined in ISO 16293-1. This document applies to float glass supplied in stock sizes and final cut sizes. 2 Norma
15、tive references There are no normative references in this document. 3 T erms a nd definiti ons For the purposes of this document, the terms and definitions given in ISO 16293-1 and the following apply. ISO and IEC maintain terminological databases for use in standardization at the following addresse
16、s: IEC Electropedia: available at h t t p :/ www .electropedia .org/ ISO Online browsing platform: available at h t t p :/ www .iso .org/ obp 3.1 length H dimension of the straight edge of the glass parallel to the direction of draw of the glass ribbon Note 1 to entry: See Figure 1. SOURCE: ISO 1148
17、5-1:2011, 2.26, modified l H B Key l direction of draw H length B width Figure 1 Relationship between length, width and direction of draw ISO 2017 All rights reserved 1 ISO 16293-2:2017(E) 3.2 width B dimension of the edge of the glass perpendicular to the direction of the glass ribbon Note 1 to ent
18、ry: See Figure 1. 3.3 stock sizes glass sizes that are intended to be re-cut to obtain final cut sizes (3.7) Note 1 to entry: Stock sizes can be jumbo sizes, split sizes or supplied sizes. 3.4 jumbo sizes glass delivered in the following sizes:Nominal length H: 4 500 mm, 5 100 mm or 6 000 mm;Nominal
19、 width B: 3 210 mm Note 1 to entry: The usual width is 3 210 mm. Exceptional production requirements can cause this to be reduced, but the nominal width is never below 3 150 mm. Note 2 to entry: The usual maximum length is 6 000 mm. Oversize plates where the nominal length, H, is greater than 6 000
20、mm, can be produced to special order. 3.5 split sizes glass delivered in the following size ranges:Nominal length H: 1 000 mm to 2 550 mm;Nominal width B: 3 210 mm Note 1 to entry: The usual width is 3 210 mm. Exceptional production requirements can cause this to be reduced, but the nominal width is
21、 never below 3 150 mm. 3.6 supplied size pane of glass that has been supplied as raw material for cutting down to a size for installation, delivered in the following size ranges:Nominal length H: any;Nominal width B: 3 210 mm Note 1 to entry: In some cases, nominal width can be B 3 810 mm 3.7 f i n
22、a l c u t s i z e pane of glass that has been cut down to the dimensions being required either for installation or processing into a final product, e.g. insulating glass units, thermally toughened safety glass, of those dimensions Note 1 to entry: The minimum final cut size shall have dimensions H o
23、r B not less than 100 mm and a minimum surface area of not less than 0,05m 2 . 3.8 optical faults faults which lead to distortions in the appearance of objects observed through the glass2 ISO 2017 All rights reserved ISO 16293-2:2017(E) 3.9 visual faults faults which alter the visual quality of the
24、glass Note 1 to entry: Visual faults include spot faults and linear/extended faults. 3.10 spot fault defect in the glass having a limited size and being composed of a nucleus, which can be accompanied by a halo (3.11) of distorted glass 3.11 halo area of glass locally distorted, generally around a n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO1629322017GLASSINBUILDINGBASICSODALIMESILICATEGLASSPRODUCTSPART2FLOATGLASS 建筑 玻璃 基本 硅酸盐 玻璃制品 部分 PDF

链接地址:http://www.mydoc123.com/p-1251556.html