ISO 16200-2-2000 Workplace air quality - Sampling and analysis of volatile organic compounds by solvent desorption gas chromatography - Part 2 Diffusive samplin.pdf
《ISO 16200-2-2000 Workplace air quality - Sampling and analysis of volatile organic compounds by solvent desorption gas chromatography - Part 2 Diffusive samplin.pdf》由会员分享,可在线阅读,更多相关《ISO 16200-2-2000 Workplace air quality - Sampling and analysis of volatile organic compounds by solvent desorption gas chromatography - Part 2 Diffusive samplin.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、Reference number ISO 16200-2:2000(E) ISO 2000 INTERNATIONAL STANDARD ISO 16200-2 First edition 2000-06-15 Workplace air quality Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Part 2: Diffusive sampling method Qualit de lair des lieux de travail chantillo
2、nnage et analyse des composs organiques volatils par dsorption au solvant/chromatographie en phase gazeuse Partie 2: Mthode dchantillonnage par diffusionISO 16200-2:2000(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be print
3、ed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no lia
4、bility in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is
5、suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. ISO 2000 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
6、 any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 734 10 79 E-ma
7、il copyrightiso.ch Web www.iso.ch Printed in Switzerland ii ISO 2000 All rights reservedISO 16200-2:2000(E) ISO 2000 All rights reserved iii Contents Page 1 Scope 1 2 Normative references 1 3 Principle1 4 Reagents and materials 2 5 Apparatus .4 6 Sampling.5 7 Procedure .6 7.1 Desorption6 7.2 Analysi
8、s 6 7.3 Determination of desorption efficiency.6 7.4 Calibration of uptake rate .7 8 Calculations8 8.1 General8 8.2 Mass concentration of analyte .8 8.3 Volume concentration of analyte .9 8.4 Uptake rates .9 9 Interferences 9 10 Precision and bias .9 11 Storage and transport .10 12 Test report 10 13
9、 Quality control10 Annex A (informative) Description of sorbent types .11 Annex B (informative) Diffusive sampling rates (cm 3 /min)12 Annex C (informative) Equivalence of gas chromatographic stationary phases .20 Annex D (informative) Suppliers of charcoal-based organic vapour diffusive samplers21
10、Annex E (informative) Specific information on sampler type A .22 Annex F (informative) Specific information on sampler type B .23 Annex G (informative) Specific information on sampler type C.24 Annex H (informative) Specific information on sampler type D .25 Annex I (informative) Specific informatio
11、n on sampler type E.26 Annex J (informative) Retention indices of selected VOCS on BP-1 and BP-10 phases.27 Bibliography31ISO 16200-2:2000(E) iv ISO 2000 All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
12、member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, govern
13、mental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Di
14、rectives, Part 3. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the
15、elements of this part of ISO 16200 may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. International Standard ISO 16200-2 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 2, Workplace atmospheres. ISO 16200
16、 consists of the following parts, under the general title Workplace air quality Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography: Part 1: Pumped sampling method Part 2: Diffusive sampling method Annexes A to J of this part of ISO 16200 are for information
17、only.INTERNATIONAL STANDARD ISO 16200-2:2000(E) ISO 2000 All rights reserved 1 Workplace air quality Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Part 2: Diffusive sampling method 1 Scope This part of ISO 16200 gives general guidance for the sampling a
18、nd analysis of volatile organic compounds (VOCs) in air. This part of ISO 16200 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of devices and sorbents are recommended for the sampling of these VOCs, each
19、sorbent having a different range of applicability. NOTE Activated coconut shell charcoal is frequently used. Very polar compounds may require derivatization; very low boiling compounds will only be partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds wi
20、ll be fully retained by the sorbents, but may only be partially recovered. This part of ISO 16200 is valid for the measurement of airborne vapours of VOCs in a concentration range of approximately 1 mg/m 3 to 1000 mg/m 3 individual organic for an exposure time of 8 h. The upper limit of the useful r
21、ange is set by the sorptive capacity of the sorbent used and, subject to dilution of the analysed solution, by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depen
22、ds on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sampling devices or in the desorption solvent. Artefacts are typically sub-nanogram for activated charcoal, but higher levels of aromatic hydrocarbons have been noted in some batches. 2 Normative
23、 references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of ISO 16200. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on th
24、is part of ISO 16200 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid I
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO1620022000WORKPLACEAIRQUALITYSAMPLINGANDANALYSISOFVOLATILEORGANICCOMPOUNDSBYSOLVENTDESORPTIONGASCHROMATOGRAPHYPART2DIFFUSIVESAMPLINPDF

链接地址:http://www.mydoc123.com/p-1251541.html