ISO 13017 AMD 1-2015 Dentistry - Magnetic attachments Amendment 1《牙科 磁性附着体 修改件1》.pdf
《ISO 13017 AMD 1-2015 Dentistry - Magnetic attachments Amendment 1《牙科 磁性附着体 修改件1》.pdf》由会员分享,可在线阅读,更多相关《ISO 13017 AMD 1-2015 Dentistry - Magnetic attachments Amendment 1《牙科 磁性附着体 修改件1》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2015 Dentistry Magnetic attachments AMENDMENT 1 Mdecine bucco-dentaire Attaches magntiques AMENDEMENT 1 INTERNATIONAL STANDARD ISO 13017 First edition 2012-07-15 Reference number ISO 13017:2012/Amd.1:2015(E) AMENDMENT 1 2015-11-15 ISO 13017:2012/Amd.1:2015(E)ii ISO 2015 All rights reserved COPY
2、RIGHT PROTECTED DOCUMENT ISO 2015, Published in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, w
3、ithout prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Ch. de Blandonnet 8 CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22 749 09 47 copyrightiso.org www.
4、iso.org ISO 13017:2012/Amd.1:2015(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body
5、interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotech
6、nical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO
7、documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2. www.iso.org/directives Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsibl
8、e for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received. www.iso.org/patents Any trade name used in this document is information given for the co
9、nvenience of users and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT), see the following URL: Fore
10、word - Supplementary information The committee responsible for this document is ISO/TC 106, Dentistry, Subcommittee SC 2, Prosthodontic materials. ISO 2015 All rights reserved iii Dentistry Magnetic attachments AMENDMENT 1 Page 1, Clause 2 Add the following reference: “ISO 14233, Dentistry Polymer-b
11、ased die materials”Page 1, Clause 3 Replace the definition of 3.1 with the following: “device to provide retention of a prosthesis utilizing magnetic attraction” Replace the definition of 3.1.1 with the following: “magnetic attachment which utilizes an open magnetic circuit between the coupled devic
12、e components” Replace the NOTE of 3.1.1 with the following: “The magnet is encased within a corrosion-resistant metal or alloy cover of titanium, titanium alloy or stainless steel to prevent corrosion of the magnet. The attachment uses either a magnet and a ferromagnetic alloy keeper or two magnets
13、as retentive coupling components.”Page 2, Clause 3 Replace the definition of 3.2 with the following: “assembly composed of a small magnet which is sealed within ferromagnetic yokes and a non- magnetic spacer, completing a closed magnetic circuit with a keeper”Page 3, Clause 3 Replace the definition
14、of 3.3 with the following: “ferromagnetic alloy component fixed to an abutment to retain a prosthesis” Replace the NOTE of 3.3 with the following: “The keeper is placed across the poles of a magnet or a magnetic assembly to complete the magnetic circuit.” Replace the definition of 3.4 with the follo
15、wing: “ferromagnetic alloy component connected to a permanent magnet and used for concentrating magnetic flux” ISO 13017:2012/Amd.1:2015(E) ISO 2015 All rights reserved 1 ISO 13017:2012/Amd.1:2015(E) Page 4, Subclause 4.4 Replace the superscript number “ 3 ” with the superscript number “ 5 ”.Page 4,
16、 Subclause 4.6.1 Replace the cross-reference “(see 6.4.1.4)” with “(see 6.4.1.3)”.Page 4, Subclause 4.6.2 Replace the existing subclause with the following: “Breakdown potentials of the magnet or the magnetic assembly and the keeper shall be equal to, or higher than, that of wrought stainless steel
17、in accordance with ISO 5832-1 when tested in accordance with 6.4.2.”Page 4, Subclause 5.1 Replace the cross-reference “(see 6.3.2)” with “(see 6.3.4)”.Page 5, Subclause 6.2.1.1 Replace the existing text with the following: “Gauss meter, using a Hall element and in accordance with ISO/IEC 17025.”Page
18、 5, Subclause 6.2.2 Replace the cross-reference to “(6.2.1)” with “(6.2.1.1)”.Page 5, Subclause 6.3.1.2 Replace the existing text with the following: “Device, containing a low friction ball bearing slider, for fixing and pulling the specimens vertically, installed in the mechanical testing machine.
19、NOTE The force required to move the shaft of the device when pulling a specimen should be 0,02 N or less. The lower or upper table can be modified to facilitate fixation of the specimen (magnet, magnetic assembly, or keeper) in a stable manner. See Figure 3.”Page 5, Subclause 6.3.1.2 Add the followi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO13017AMD12015DENTISTRYMAGNETICATTACHMENTSAMENDMENT1 牙科 磁性 附着 修改 PDF

链接地址:http://www.mydoc123.com/p-1250635.html