ISO 12645-1998 Graphic technology - Process control - Certified reference material for opaque area calibration of transmission densitometers《印刷技术 过程控制 用于透射密度计不透.pdf
《ISO 12645-1998 Graphic technology - Process control - Certified reference material for opaque area calibration of transmission densitometers《印刷技术 过程控制 用于透射密度计不透.pdf》由会员分享,可在线阅读,更多相关《ISO 12645-1998 Graphic technology - Process control - Certified reference material for opaque area calibration of transmission densitometers《印刷技术 过程控制 用于透射密度计不透.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、A Referencenumbe r ISO12645:1998 (E) INTERNATIONAL STANDARD ISO 12645 Firstedition 19981101 GraphictechnologyProcesscontrol Certifiedreferencematerialforopaquearea calibrationoftransmissiondensitometers TechnologiegraphiqueMatrisedeprocdMatrielderfrence certifipourlacalibrationdesdensitomtrestransmi
2、ssionenpourcentage desuperficieopaqueISO12645:1998(E) ISO1998 Allrightsreserved.Unlessotherwisespecified,nopartofthispublicationmaybereproducedorutilizedinanyformorbyan ymeans,electronic ormechanical,includingphotocopyingandmicrofilm,withoutpermissioninwritingfromthepublisher. InternationalOrganizat
3、ionforStandardization Casepostale56 CH1211Genve20 Switzerland Internet isoiso.ch PrintedinSwitzerland ii Foreword ISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISO memberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughIS
4、Otechnical committees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeenestablishedhas therighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnongovernmental,in liaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththeInternationalElectrotechnical
5、 Commission(IEC)onallmattersofelectrotechnicalstandardization. DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting. PublicationasanInternationalStandardrequiresapprovalbyatleast75%ofthememberbodiescastingavote. InternationalStandardISO12645waspreparedbyT
6、echnicalCommitteeISO/TC130, Graphictechnology . AnnexesAtoEofthisInternationalStandardforinformationonly.ISO ISO12645:1998(E) iii Introduction Inthegraphicarts,themodulationoftransmittanceorreflectanceisoftenachievedbyprintinghalftonesratherthan continuoustones,aswouldbethecaseinphotography. Theproc
7、esscontrolofthegenerationandtransferofhalftonepatternsisessentialtothegraphicartsindustry.For theprocesscontroloftransmissiontypematerialonemonitorsthepercentageofthetotalareathatisvirtually opaque.Measurementsarecarriedoutonwelldefinedhalftonecontrolpatcheswhichcontainregularlyspaced, circularhalft
8、onedots.Themeasuringinstrumentiseitheradensitometeroracolorimeterofthespectrophotometer ortristimulustype.Theopaqueareapercentageisusuallysetequaltotheratiooftherelativetransmittancefactors ofthehalftoneandthatofthesolid.WithdensitometersonecalculatesthetransmittancefactorsfromtheISO standarddiffuse
9、(opal)densities,thecorrespondingexpressionfortheratiohasbeengivenbyMurrayandDavies, seeE.2andequations(1)and(2)ofclause3. Inprinciple,theopaqueareapercentageforpositivepolarityfilmsshouldbeidenticaltothetonevalueasdefinedin thegraphicarts;fornegativepolarityfilmsitshouldbeidenticalto100%minusthetone
10、value.Inreality,however, theremaybeerrorswhichproducesmalldeviationsbetweenthetwoquantities;thereisthusaneedforan independentcheckonthedeterminationofthetonevaluebydensitometersandcolorimeters. Inthegraphicartsprocesschain,particularlyimportantstepsare“imagesetting“,“filmduplication“and “platemaking
11、“.Duringthesesteps,thereisnohighlydiffusivemediumpresentwhichcouldbecomparedtothe opalglassdiffuserofdensitometersaccordingtoISO52E.3.Itwouldthusappearthattheopalglassinstrument isnotthebestsolutionforgraphicartsapplications.However,theopalglassdesignpermitsarelativelysimple construction;suchinstrum
12、entsarewidelyusedinthegraphicartsindustry. Whencalibratingadensitometerwithasteppeddensityreferencematerial(atleasttwosteps),usuallyboththezero pointandtheslopefactorareadjusted.Thelatteristheratioofthedensitydifferencebetweenthestepsasreadby thedensitometerandthedensitydifferenceasreportedbyanation
13、alstandardizinglaboratory.Iftheratiodeviates from1,thebaseofthelogarithmusedforconvertingtransmittancefactorintotransmittancefactordensityisnot10 asrequiredbydefinition.Asaconsequence,thetonevaluescalculatedfromthedensitiesmaydeviatefromthe opaqueareapercentages.Itisimportanttonotethatthe(absolute)I
14、SOstandarddiffusedensitycalibrationofa densitometermaybedependentonthethicknessofthesample.Thesteppeddensityreferencematerialusedfor thedensitycalibrationshouldthereforehavethesamethicknessasthesamplestobemeasured,otherwiseonly relativedensitiescanbemeasured.Formanygraphicartsapplications,however,ab
15、solutedensitymeasurements arenottheissuebutthecontroloftheopaqueareapercentageofhalftonefilm.Thisquantitydeterminesthesize ofimageelements,suchashalftonedotsorlines,producedbytransferstepssuchasfilmduplicationand platemaking.Thedensitometeristhenzeroedontheclearfilmandthedensitiesofahalftoneandasoli
16、dare measured.TheMurrayDaviesformula,E.2andequations(1)and(2)ofclause3,isusedtodeterminetone valuesfromthedensityvalues,seealsoISO126471. Itisknownthattransmissiondensitometersoftheopaltypearesubjecttomultipleobliqueangleinterreflections betweentheopalandthesurfacesclosetoit,seeISO52E.3.Theseinclude
17、thetwosurfacesofthesampleand thoseonthesideoftheinstrumentopposingtheopal.Forsamplesoflowdensity,reflectionsfromallthose surfacesmaycontributetotheeffluxmeasuredatthebackoftheopal.At(absolute)ISOstandarddiffusedensities nearzero,thedensitiesreadbyanopalinstrumentarethusslightlylowerthanthoseofadiffu
18、sespheretype instrument;0,03isatypicaldifference.Thiseffecthastobetakenintoaccountiftransmissiondensitiesor reflectancefactorsreadbyinstrumentsofdifferentdesignarecompared.Forsamplesofhigherdensities,the reflectionsfromallsurfacesbutthesurfacenexttotheopalareeffectivelysuppressed.Duringthemeasuremen
19、tof ahalftonepattern,thelatterinfluencestheinterreflectioneffectintwoways:Theimageelementsmayhavea reflectancedifferentfromthefilmbase,theyalsotendtoattenuatereflectionsfromsurfacesfurtherremovedfrom theopal.Therefore,thetonevaluesdeterminedfromdensitiesmeasuredwithanopalinstrumentmaydifferfrom thea
20、ctualopaqueareapercentageofthesamplewhichcanbedeterminedbymicroscopicmeasurementorbya spheretypeinstrument(whichdoesnotshowtheinterreflectioneffect). ISO126471specifiesthattransmissiondensitiesshallbemeasuredbyinstrumentscomplyingtoISO52,thus therecanbenoambiguitywhenquoting(absolute)ISOstandarddiff
21、usedensitiessuchasclearfilmdensities.ISO12645:1998(E) ISO iv Theinterreflectioneffectcanbeartificiallyattenuatediftheopaliskeptatadistanceof,say,25mmfromthe measuredobject.Anothermethodistoplaceaneutralfilterwithadensityofatleast0,3betweentheopalandthe sample.Thefiltertendstoattenuatethelightcomingb
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO126451998GRAPHICTECHNOLOGYPROCESSCONTROLCERTIFIEDREFERENCEMATERIALFOROPAQUEAREACALIBRATIONOFTRANSMISSIONDENSITOMETERS

链接地址:http://www.mydoc123.com/p-1250548.html