ISO 10803-2011 Design method for ductile iron pipes《球墨铸铁管的设计方法》.pdf
《ISO 10803-2011 Design method for ductile iron pipes《球墨铸铁管的设计方法》.pdf》由会员分享,可在线阅读,更多相关《ISO 10803-2011 Design method for ductile iron pipes《球墨铸铁管的设计方法》.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference number ISO 10803:2011(E) ISO 2011INTERNATIONAL STANDARD ISO 10803 Second edition 2011-12-01 Design method for ductile iron pipes Mthode de calcul des tuyaux en fonte ductile ISO 10803:2011(E) COPYRIGHT PROTECTED DOCUMENT ISO 2011 All rights reserved. Unless otherwise specified, no part of
2、 this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH
3、-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2011 All rights reservedISO 10803:2011(E) ISO 2011 All rights reserved iiiContents Page Foreword iv 1 Scope 1 2 Normative references 1 3 Terms and definitions . 1 4 De
4、sign procedure 2 5 Design for internal pressure 3 6 Design for external loads 3 Annex A (informative) Dimensions of preferred and other class pipes 9 Annex B (informative) Allowable depths of cover for pipes conforming to ISO 2531 . 12 Annex C (informative) Allowable depths of cover for pipes confor
5、ming to ISO 7186 . 54 Annex D (informative) Trench types . 58 Annex E (informative) Soil classification 59 Bibliography 60 ISO 10803:2011(E) iv ISO 2011 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO me
6、mber bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governme
7、ntal and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Dire
8、ctives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bod
9、ies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 10803 was prepared by Technical Committee ISO/TC 5, Ferrous metal pipes and m
10、etallic fittings, Subcommittee SC 2, Cast iron pipes, fittings and their joints. This second edition cancels and replaces the first edition (ISO 10803:1999), which has been technically revised. INTERNATIONAL STANDARD ISO 10803:2011(E) ISO 2011 All rights reserved 1Design method for ductile iron pipe
11、s 1 Scope This International Standard specifies the design of ductile iron pipes used for conveying water, sewerage and other fluids with or without internal pressure, and with or without earth and traffic loading. 2 Normative references The following referenced documents are indispensable for the a
12、pplication of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 2531, Ductile iron pipes, fittings, accessories and their joints for water applications ISO 7186, Ductile i
13、ron products for sewerage applications ISO 7268, Pipe components Definition of nominal pressure ISO 10802, Ductile iron pipelines Hydrostatic testing after installation 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 7268 and the following apply. 3.1
14、 allowable operating pressure PFA maximum internal pressure, excluding surge, which a component can safely withstand in permanent service 3.2 allowable maximum operating pressure PMA maximum internal pressure, including surge, which a component can safely withstand in service 3.3 allowable site test
15、 pressure PEA maximum hydrostatic pressure that a newly installed component can withstand for a relatively short duration, when either fixed above ground level or laid and backfilled underground, in order to ensure the integrity and leaktightness of the pipeline NOTE This test pressure is different
16、from the system test pressure, which is related to the design pressure of the pipeline. ISO 10803:2011(E) 2 ISO 2011 All rights reserved3.4 embedment arrangement and type(s) of material around a buried pipeline, which contribute to its structural performance See Figure D.1. 3.5 bedding lower part of
17、 the embedment, composed of the lower bedding (if necessary) and the upper bedding See Figure D.1. 3.6 bedding reaction angle conventional angle used in the calculation model to account for the actual soil pressure distribution at pipe invert 3.7 compaction deliberate densification of soil during th
18、e installation process 3.8 standard Proctor density degree of soil compaction, as defined in AASHTO T99 using a 2,5 kg rammer and a 305 mm drop 4 Design procedure 4.1 The pipe wall thickness shall provide adequate strength against the internal pressure of the fluid and against the effects of externa
19、l loads due to backfill and surcharge, i.e. traffic loadings. Ductile iron pipes in compliance with ISO 2531 are classified according to their allowable operating pressure for use in water applications. Ductile iron pipes in compliance with ISO 7186 are for sewerage applications either under pressur
20、e or under gravity. Using the equations given in Clauses 5 and 6, the design of buried pipes is performed by determining a) the minimum pipe wall thickness for the allowable operating pressure (PFA), and b) the depths of cover as given in Annexes B and C. 4.2 The design procedure for the pipes is th
21、e following: a) from the allowable operating pressure of the pipeline, select the class of pipe as appropriate from ISO 2531 or ISO 7186 the minimum pipe wall thickness of these pipes has been calculated from Equation (1); b) calculate the allowable depth of cover in accordance with Clause 6; c) if
22、the allowable depth of cover is not adequate, select higher a pressure class of pipe and repeat steps 4.2 a) and b) until the allowable depth of cover is acceptable. NOTE 1 In practice, in most cases, the pressure class and the allowable depth of cover for the pipes can be selected from the appropri
23、ate tables in Annexes B or C without carrying out the detailed calculations as explained above. NOTE 2 When installed and operated under the conditions for which they are designed, ductile iron pipes, fittings, accessories and their joints maintain all their functional characteristics over their ope
24、rating life, due to constant material properties, to the stability of their cross-section and to their design with high safety factors. NOTE 3 In certain countries, national standards or regulations can specify other design procedures. ISO 10803:2011(E) ISO 2011 All rights reserved 35 Design for int
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO108032011DESIGNMETHODFORDUCTILEIRONPIPES 球墨铸铁 设计 方法 PDF

链接地址:http://www.mydoc123.com/p-1249892.html