ACI 437 2-2013 Code Requirements for Load Testing of Existing Concrete Structures (ACI 437 2-13) and Commentary.pdf
《ACI 437 2-2013 Code Requirements for Load Testing of Existing Concrete Structures (ACI 437 2-13) and Commentary.pdf》由会员分享,可在线阅读,更多相关《ACI 437 2-2013 Code Requirements for Load Testing of Existing Concrete Structures (ACI 437 2-13) and Commentary.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、ACI 437.2-13Code Requirements for Load Testing of Existing Concrete Structures (ACI 437.2-13) and CommentaryAn ACI StandardReported by ACI Committee 437First PrintingJanuary 2014Code Requirements for Load Testing of Existing Concrete Structures and CommentaryCopyright by the American Concrete Instit
2、ute, Farmington Hills, MI. All rights reserved. This material may not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ACI.The technical committees responsible for ACI committee reports an
3、d standards strive to avoid ambiguities, omissions, and errors in these documents. In spite of these efforts, the users of ACI documents occasionally find information or requirements that may be subject to more than one interpretation or may be incomplete or incorrect. Users who have suggestions for
4、 the improvement of ACI documents are requested to contact ACI via the errata website at http:/concrete.org/Publications/DocumentErrata.aspx. Proper use of this document includes periodically checking for errata for the most up-to-date revisions.ACI committee documents are intended for the use of in
5、dividuals who are competent to evaluate the significance and limitations of its content and recommendations and who will accept responsibility for the application of the material it contains. Individuals who use this publication in any way assume all risk and accept total responsibility for the ap-p
6、lication and use of this information.All information in this publication is provided “as is” without warranty of any kind, either express or implied, includ-ing but not limited to, the implied warranties of merchantability, fitness for a particular purpose or non-infringement.ACI and its members dis
7、claim liability for damages of any kind, including any special, indirect, incidental, or con-sequential damages, including without limitation, lost revenues or lost profits, which may result from the use of this publication.It is the responsibility of the user of this document to establish health an
8、d safety practices appropriate to the specific circumstances involved with its use. ACI does not make any representations with regard to health and safety issues and the use of this document. The user must determine the applicability of all regulatory limitations before applying the document and mus
9、t comply with all applicable laws and regulations, including but not limited to, United States Occupational Safety and Health Administration (OSHA) health and safety standards.Participation by governmental representatives in the work of the American Concrete Institute and in the develop-ment of Inst
10、itute standards does not constitute governmental endorsement of ACI or the standards that it develops.Order information: ACI documents are available in print, by download, on CD-ROM, through electronic subscription, or reprint and may be obtained by contacting ACI.Most ACI standards and committee re
11、ports are gathered together in the annually revised ACI Manual of Concrete Practice (MCP).American Concrete Institute38800 Country Club DriveFarmington Hills, MI 48331U.S.A.Phone: 248-848-3700Fax: 248-848-3701www.concrete.orgISBN: 978-0-87031-857-3American Concrete InstituteAdvancing concrete knowle
12、dgeACI 437.2-13Code Requirements for Load Testing of Existing Concrete Structures (ACI 437.2-13) and CommentaryReported by ACI Committee 437Carl J. Larosche*, Chair J. Gustavo Tumialan*, SecretaryJoseph A. AmonNicholas J. CarinoPaolo CasadeiJohn A. FrauenhofferNestore Galati*Zareh B. GregorianPawan
13、R. GuptaFrederick D. HeidbrinkAshok M. KakadeDanielle D. KleinhansAndrew T. KrauklisDaniel J. McCarthyJaveed MunshiAntonio NanniThomas E. Nehil*Renato ParrettiK. Nam ShiuJeffrey S. West*Paul H. Ziehl*Consulting MembersMarco ArduiniHabib M. Zein Alabideen*Member of the subcommittee that prepared this
14、 reportThis code provides requirements for test load magnitudes, test protocols, and acceptance criteria for conducting a load test as a means of evaluating the safety and serviceability of concrete struc-tural members and systems for existing buildings as provided for by ACI 562-13. A load test may
15、 be conducted as part of a struc-tural evaluation to determine whether an existing building requires repair and rehabilitation, or to verify the adequacy of repair and rehabilitation measures applied to an existing building, or both. This code contains provisions for both a cyclic load test and a mo
16、notonic load test procedure.Keywords: acceptance criteria; cyclic loading; load test; monotonic loading; test load magnitude; test protocol.CONTENTSCHAPTER 1GENERAL, p. 31.1General, p. 31.2Scope, p. 31.3Purpose, p. 31.4Limitations, p. 41.5Interpretation, p. 41.6Language and units of measurement, p.
17、4CHAPTER 2NOTATION AND DEFINITIONS, p. 52.1Notation, p. 52.2Definitions, p. 6CHAPTER 3REFERENCED STANDARDS, p. 8CHAPTER 4TEST LOAD, p. 94.1Service loads, p. 94.2Test load magnitude, p. 91ACI 437.2-13 replaces ACI 437-12, was adopted October 23, 2013, and published January 2014.Copyright 2014, Americ
18、an Concrete Institute.All rights reserved including rights of reproduction and use in any form or by any means, including the making of copies by any photo process, or by electronic or mechanical device, printed, written, or oral, or recording for sound or visual reproduc-tion or for use in any know
19、ledge or retrieval system or device, unless permission in writing is obtained from the copyright proprietors.CHAPTER 5LOADING PROTOCOL, p. 115.1Safety, p. 115.2Load arrangement, p. 115.3Monotonic loading protocol, p. 125.4Cyclic loading protocol, p. 125.5Load application, p. 135.6Response measuremen
20、ts, p. 145.7Visual inspection, p. 14CHAPTER 6ACCEPTANCE CRITERIA, p. 156.1Distress caused by load test, p. 156.2Performance assessment at service load level, p. 166.3Acceptance criteria for monotonic loading protocol, p. 176.4Acceptance criteria for cyclic loading protocol, p. 176.5Provision for low
21、er load rating, p. 19R7COMMENTARY REFERENCES, p. 21Cited references, p. 21American Concrete Institute Copyrighted Materialwww.concrete.org2 CODE REQUIREMENTS FOR LOAD TESTING OF EXISTING CONCRETE STRUCTURES (ACI 437.2-13)CHAPTER 1GENERAL 1.1General 1.1.1 The scope, purpose, applicability, limitation
22、s, inter-pretation principles, and units of measure are defined in this chapter.1.1.2 This code supplements and is part of the “Code Requirements for Evaluation, Repair, and Rehabilitation of Existing Concrete Buildings (ACI 562-13) and Commen-tary” through reference. 1.2Scope 1.2.1 The requirements
23、 of this code shall govern for the evaluation of safety and serviceability of members in existing concrete structures by load testing.1.2.2 The requirements of this code shall apply to rein-forced concrete with prestressed reinforcement, nonpre-stressed reinforcement, or both.1.2.3 Procedures and re
24、quirements provided in this code are not applicable to existing structures having concretes with compressive strengths above 8000 psi unless permitted by the licensed design professional.1.2.4 For structures being erected under the requirements of a legally adopted general building code, of which AC
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACI43722013CODEREQUIREMENTSFORLOADTESTINGOFEXISTINGCONCRETESTRUCTURESACI437213ANDCOMMENTARYPDF

链接地址:http://www.mydoc123.com/p-1242866.html