VA 28 05 28 33-2011 CONDUITS AND BACKBOXES FOR ELECTRONIC SAFETY AND SECURITY.pdf
《VA 28 05 28 33-2011 CONDUITS AND BACKBOXES FOR ELECTRONIC SAFETY AND SECURITY.pdf》由会员分享,可在线阅读,更多相关《VA 28 05 28 33-2011 CONDUITS AND BACKBOXES FOR ELECTRONIC SAFETY AND SECURITY.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、09-11 28 05 28.33 - 1 SECTION 28 05 28.33 CONDUITS AND BACKBOXES FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete between /_/if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION A.
2、 This section specifies the finishing, installation, connection, testing certification of the conduit, fittings, and boxes to form a complete, coordinated, raceway system(s). Conduits and when approved separate UL Certified and Listed partitioned telecommunications raceways are required for a fully
3、functional Electronic Safety and Security (ESS) system. Raceways are required for all electronic safety and security cabling unless shown or specified otherwise. B. Definitions: The term conduit, as used in this specification, shall mean any or all of the raceway types specified. 1.2 RELATED WORK SP
4、EC WRITER NOTE: Delete any item or paragraph not applicable in the section and renumber the paragraphs. A. Section 01 00 00 - GENERAL REQUIREMENTS. For General Requirements. B. Section 06 10 00 - ROUGH CARPENTRY. Requirements for mounting board for communication closets. C. Section 07 84 00 - FIREST
5、OPPING. Requirements for sealing around penetrations to maintain the integrity of fire rated construction. D. Section 07 60 00 - FLASHING AND SHEET METAL. Requirements for fabrications for the deflection of water away from the building envelope at penetrations. E. Section 07 92 00 - JOINT SEALANTS.
6、Requirements for sealing around conduit penetrations through the building envelope to prevent moisture migration into the building. F. Section 09 91 00 - PAINTING. Requirements for identification and painting of conduit and other devices. G. Section 28 05 00 - COMMON WORK RESULTS FOR ELECTRONIC SAFE
7、TY AND SECURITY. For general electrical requirements, general arrangement of the contract documents, coordination, quality assurance, project conditions, equipment and materials, and items that is common to more than one section of Division 28. H. Section 28 05 26 - GROUNDING AND BONDING FOR ELECTRO
8、NIC SAFETY AND SECURITY. Requirements for personnel safety and to provide a low impedance path for possible ground fault currents. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 28 05 28.33 - 2 I. Section 28 08 00 - COMMISIONING OF ELECTRONIC
9、SAFETY AND SECURITY SYSTEMS. Requirements for commissioning - systems readiness checklists, and training. J. Section 31 20 00 - EARTH MOVING. For bedding of conduits. 1.3 DEFINITIONS SPEC WRITER NOTE: Retain abbreviations that remain after this Section has been edited. A. EMT: Electrical metallic tu
10、bing. B. ENT: Electrical nonmetallic tubing. C. EPDM: Ethylene-propylene-diene terpolymer rubber. D. FMC: Flexible metal conduit. E. IMC: Intermediate metal conduit. F. LFMC: Liquidtight flexible metal conduit. G. LFNC: Liquidtight flexible nonmetallic conduit. H. NBR: Acrylonitrile-butadiene rubber
11、. I. RNC: Rigid nonmetallic conduit. 1.4 QUALITY ASSURANCE A. Refer to Paragraph 1.4 Quality Assurance, in Section 28 05 00, COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY. 1.5 SUBMITTALS A. Submit in accordance with Section 28 05 00, COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY an
12、d Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Furnish the following: B. Shop Drawings: 1. Size and location of main feeders; 2. Size and location of panels and pull boxes 3. Layout of required conduit penetrations through structural elements. 4. The specific item proposed and its are
13、a of application shall be identified on the catalog cuts. C. Certification: Prior to final inspection, deliver to the Resident Engineer/COTR four copies of the certification that the material is in accordance with the drawings and specifications and has been properly installed. D. Completed System R
14、eadiness Checklists provided by the Commissioning Agent and completed by the contractor, signed by a qualified technician and dated on the date of completion, in accordance with the requirements of Section 28 08 00 COMMISSIONING OF ELECTRONIC SAFETY AND SECURITY SYSTEMS. E. Product Data: For surface
15、 raceways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 28 05 28.33 - 3 F. Shop Drawings: For the following raceway components. Include plans, elevations, sections, d
16、etails, and attachments to other work. SPEC WRITER NOTE: Retain subparagraph below for custom enclosures only. 1. Custom enclosures and cabinets. SPEC WRITER NOTE: Retain subparagraph and associated subparagraphs below if handholes or boxes for underground wiring are specified. 2. Handholes and boxe
17、s for underground wiring, including the following: a. Duct entry provisions, including locations and duct sizes. b. Frame and cover design. c. Grounding details. d. Dimensioned locations of cable rack inserts, and pulling-in and lifting irons. e. Joint details. SPEC WRITER NOTE: Retain paragraph and
18、 subparagraphs below if Drawings do not include detailed conduit routing plans and if Project involves unusual coordination requirements. G. Coordination Drawings: Conduit routing plans, drawn to scale, on which the following items are shown and coordinated with each other, based on input from insta
19、llers of the items involved: 1. Structural members in the paths of conduit groups with common supports. 2. HVAC and plumbing items and architectural features in the paths of conduit groups with common supports. SPEC WRITER NOTE: Retain paragraph and subparagraphs below if required by seismic criteri
20、a applicable to Project. Coordinate with Division 16 Section “Electrical Supports and Seismic Restraints.“ H. Manufacturer Seismic Qualification Certification: Submit certification that enclosures and cabinets and their mounting provisions, including those for internal components, will withstand sei
21、smic forces defined in Division 16 Section “Electrical Supports and Seismic Restraints.“ Include the following: 1. Basis for Certification: Indicate whether withstand certification is based on actual test of assembled components or on calculation. SPEC WRITER NOTE: Retain option in first subparagrap
22、h below for essential facilities where equipment must operate immediately after an earthquake. a. The term “withstand“ means “the cabinet or enclosure will remain in place without separation of any parts when subjected to the seismic forces specified and the unit will retain its enclosure Provided b
23、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 28 05 28.33 - 4 characteristics, including its interior accessibility, after the seismic event.“ 2. Dimensioned Outline Drawings of Equipment Unit: Identify center of gravity and locate and describe mountin
24、g and anchorage provisions. 3. Detailed description of equipment anchorage devices on which the certification is based and their installation requirements. I. Source quality-control test reports. 1.6 APPLICABLE PUBLICATIONS A. Publications listed below (including amendments, addenda, revisions, supp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA280528332011CONDUITSANDBACKBOXESFORELECTRONICSAFETYANDSECURITYPDF

链接地址:http://www.mydoc123.com/p-1074999.html