VA 12 34 00-2011 MANUFACTURED PLASTIC CASEWORK.pdf
《VA 12 34 00-2011 MANUFACTURED PLASTIC CASEWORK.pdf》由会员分享,可在线阅读,更多相关《VA 12 34 00-2011 MANUFACTURED PLASTIC CASEWORK.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、11-11 12 34 00 - 1 SECTION 12 34 00 MANUFACTURED PLASTIC CASEWORK SPEC WRITER NOTES: 1. Delete between /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 2. Verify casework identified on drawing by prefix “MVL“. PART 1
2、 GENERAL 1.1 DESCRIPTION A. This section specifies interchangeable modular plastic casework system with countertops. B. System includes support components, storage units, accessories, electrical wiring chases, for wall hung and island arrangements. C. Casework identified by prefix “MVL“. 1.2 RELATED
3、 WORK A. Instructions: SECTION 01 00 00, GENERAL REQUIREMENTS. B. Steel studs 1.2 mm (0.047 inch, 18 gage) and heavier: SECTION 05 40 00, COLD-FORMED METAL FRAMING. C. Backing plates for wall mounted items: SECTION 09 22 16, NON-STRUCTURAL METAL FRAMING. D. Colors, patterns and finishes selected: SE
4、CTION 09 06 00, SCHEDULE FOR FINISHES. E. Other metal caseworks: SECTION 12 31 00, MANUFACTURED METAL CASEWORK. F. Countertop construction and materials and items installed in countertops: SECTION 12 36 00, COUNTERTOPS. G. Plumbing requirements: DIVISION 22, PLUMBING. H. Electrical requirements: DIV
5、ISION 26, ELECTRICAL. 1.3 SUBMITTALS A. Submit in accordance with SECTION 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Product data: 1. Manufacturers literature and other data showing compliance with the specification. 2. List of 3 similar projects completed within last 5 years with names
6、and addresses. C. Certification: 1. Manufacturers qualifications specified. 2. Installers qualifications specified. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 12 34 00 - 2 D. Shop drawings: 1. Drawings complete, accurate and to scale. 2. S
7、how: a. Location of each component. b. Dimensions and clearance as required. c. Identify each component with both drawing identification and manufacturers product number. d. Details including cuts, holes, scribes, attachments and specialized construction requirements. 3. Installation procedures: Sho
8、w dimensions, methods of assembly, anchorage, installation and conditions relating to adjoining work. 4. Placement Listing: Itemized listing by room number of components provided. 5. Complete listing of each component used. 6. Include the weight of each component. E. Samples: 1. Support rail, 1200 m
9、m (48 inches) long. 2. Wall strip two pieces each, 1200 mm (48 inches) long. 3. Storage unit, drawers with countertop each type. 4. Storage unit, tambour door. 5. Process table. 6. Shelf unit, open. 7. Shelf unit, closed. 8. Mobile storage cart. 9. Typical service module. F. Operational and Maintena
10、nce Manual 1.4 QUALITY ASSURANCE A. Approval by Contracting Officer is required of manufacturer and installer based upon certification of qualifications specified. B. Manufacturers qualifications: 1. Manufacturer is regularly engaged in design and manufacture of modular plastic casework, casework co
11、mponents and accessories of scope and type similar to requirements of this project for a period of not less than 5 years. 2. Manufacturer has successfully completed at least 3 projects of scope and type similar to requirements of this project. C. Installer Qualifications: 1. Installer is approved by
12、 modular plastic casework manufacturer. 2. Installer has completed at least 3 projects in last 5 years in which these products were installed. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 12 34 00 - 3 1.5 DELIVERY, STORAGE AND HANDLING A. De
13、liver, store and handle to prevent damage and deterioration until final acceptance of project. B. Deliver and store materials in manufacturers original, labeled containers after building is enclosed and wet work is complete and dry. C. Store materials in a secure, locked area. D. Repair or replace d
14、amaged items due to storage or handling. 1.6 WARRANTY Warranty casework system components against structural failure of components, disassembly of cabinets, shelves and countertops subject to terms of “Warranty of Construction” article specified in FAR clause 52.246-21, except that warranty period s
15、hall be 5 years. 1.7 APPLICABLE PUBLICATIONS A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in the text by basic designation. SPEC WRITER NOTE: Update applicable specifications to current issue at time of project specification prepara
16、tion. B. American Hardwood Association: A135.4-04 Basic Hardwood C. American National Standards Institute (ANSI): A208.1-09 Particleboard D. American Society for Testing and Materials (ASTM): A36M-08 Carbon Structural Steel A167-99 (R2009) Stainless and Heat-Resisting Chromium Steel Plate Sheet and
17、Strip A283/A283M-03(R 2007) Low and Intermediate Tensile Strength Carbon Steel Plates A1008/A1008M-11 Steel Sheet, Carbon Cold-Rolled, Commercial Quality A423/A423M-09 Seamless and Electric-Welded Low-Alloy Steel Tubes A568/A568M-11 Steel, Sheet, Carbon, Structural and High-Strength, Low-Alloy Hot-R
18、olled and Cold-Rolled, General Requirements B221-08 Aluminum and Aluminum-Alloy Extruded Bars, Rods Wire, Profiles and Tubes Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 12 34 00 - 4 B456-11 Electrodeposited Coatings of Copper Plus, Nickel P
19、lus Chromium and Nickel Plus Chromium D1201-99(R2004) Polyester Thermosetting Molding Compound D4673-02(R2008) Acrylonitrite-Butadiene-Styrene (ABS) Molding and Extrusion Materials E84-11 . Surface Burning Characteristics of Plastics and Alloys Building Materials E. National Association of Architect
20、ural Metal Manufacturers (NAAMM): AMP 500-06 . Metal Finishes Manual F. National Electrical Manufacturers Association (NEMA): LD-3-05 High Pressure Decorative Laminates LD-3.1-95 Performance, Application, Fabrication and Installation of High Pressure Decorative Laminates G. National Fire Protection
21、Association (NFPA): 70-11 National Electric Code (NEC) H. National Sanitation Foundation (NSF): 30-92 Cabinetry and Laboratory Furniture for Hospitals I. U.S. Department of Commerce, Product Standard (PS): PS1-95 . Construction and Industrial Plywood J. Scientific Equipment and Furniture Association
22、 (SEFA): 2-10 . Installation of Scientific Laboratory Furniture and Equipment K. Underwriters Laboratories (UL): Annual Fire Resistance Directories PART 2- PRODUCT 2.1 DESIGN REQUIREMENTS A. Components provided by one manufacturer. Products of other manufacturers used meet specified flexibility and
23、interchangeability requirements. B. Components interchangeable to form flexible system which will accommodate change: 1. Dimensions of products are nominal and shown on drawings and schedules. 2. Hanging components modular on same increments. 3. Selectively removable and replaceable without disturbi
24、ng adjacent components. C. Combustible components: Maximum flame spread rating of 25 and smoke development of 450 when tested in accordance with ASTM E84. D. Basic Support Components: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 12 34 00 - 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA1234002011MANUFACTUREDPLASTICCASEWORKPDF