1、11-11 11 48 00 - 1 SECTION 11 48 00 CLEANING AND DISPOSAL EQUIPMENT SPEC WRITER NOTES: 1. Delete between / _ / if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber the paragraphs. 3. Select warewashing machines according to usage requi
2、rements (volume and type of ware), available space and utilities, and local plumbing codes. PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies food service warewashing equipment as follows: /1. Dishwashing machines, undercounter./ /2. Dishwashing machines, single tank, electric./ /3. Dishwas
3、hing machines, conveyer, single tank, electric./ /4. Dishwashing machines, conveyor, double tank, electric./ /5. Fight-type dish machines, rackless conveyor, electric./ /6. Dishwashing system, circular./ /7. Pot washer, electric, rack./ /8. Warewasher booster heater, electric./ 1.2 RELATED WORK A. W
4、arewashing Tables. B. Waste Disposers: Section 22 42 26, COMMERCIAL DISPOSERS. SPEC WRITER NOTE: Retain paragraph below if required for project location. C. Seismic Restraint of Equipment: Section 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS. D. Plumbing Connections: Sectio
5、n 22 11 00, FACILITY WATER DISTRIBUTION AND Section 22 13 00, FACILITY SANITARY SEWERAGE. E. Electrical Connections: Section 26 05 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW). F. Electrical Disconnect Switches: Section 26 29 21, DISCONNECT SWITCHES. 1.3 QUALITY CONTR
6、OL A. Installer Qualifications: Licensed electrician and plumber either experienced with food service equipment installation or supervised by an experienced food service equipment installer. SPEC WRITER NOTE: UL Environmental and Public Health (EPH) Classification Mark Provided by IHSNot for ResaleN
7、o reproduction or networking permitted without license from IHS-,-,-11-11 11 48 00 - 2 is currently used by UL to certify compliance with NSF/ANSI standards. Equipment evaluated by UL before 2001 may bear the UL Food Service Product Certification Mark. B. NSF Compliance: Equipment bears the NSF Cert
8、ification Mark or UL Classification Mark indicating conformance with NSF/ANSI 3. C. UL Listing: Equipment has been evaluated according to UL 921, is listed and labeled by UL. SPEC WRITER NOTE: Retain paragraph and subparagraphs below if required for project location. D. Seismic Restraint: 1. Comply
9、with requirements in Section 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS. 2. Comply with applicable guidelines for seismic restraint of kitchen equipment contained in SMACNAs “Kitchen Ventilation Systems and Food Service Equipment Guidelines 1767,“ Appendix A. E. In-Use Se
10、rvice: At least one factory-authorized service agency for equipment shall be located in the geographical area of the installation and shall have the ability to provide service within 24 hours after receiving a service call. 1.4 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS,
11、 PRODUCT DATA, AND SAMPLES. B. Manufacturers Literature and Data: 1. Include manufacturers address and telephone number. 2. Include catalog or model numbers, and illustrations and descriptions of warewashing equipment and accessories. 3. Proof of appliance being Energy Star qualified. C. Installatio
12、n Drawings: Show dimensions; method of assembly; and details of installation, adjoining construction, coordination with plumbing and electrical work, and other work required for a complete installation. D. Operating Instructions: Comply with requirements in Section 00 72 00, GENERAL CONDITIONS. 1.5
13、WARRANTY Warrant food service equipment to be free from defects in materials and workmanship in accordance with requirements of “Warranty of Construction“, FAR clause 52.246-21. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 48 00 - 3 1.6 A
14、PPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B. NSF International/American National Standards Institute (NSF/ANSI): 3-2010 . Commercial Warewashing Equipm
15、ent C. Sheet Metal and Air Conditioning Contractors National Association (SMACNA): 1767-2001 - Kitchen Ventilation Systems and Food Service Equipment Fabrication and Installation Guidelines. D. Underwriters Laboratories Inc. (UL): 921-06 . Commercial Electric Dishwashers, including revision through
16、and including March 16, 2000 PART 2 PRODUCTS SPEC WRITER NOTE: 1. Select capacity of units according to anticipated use; actual use should not exceed 80 percent of capacity of unit. 2. Symbols below correspond with “Room Equipment Guide“ identification system. Verify project requirements before spec
17、ifying equipment that deviates from “Room Equipment Guide.“ 3. Edit symbols to coordinate with identification shown on drawings. 2.1 DISHWASHING MACHINES, UNDERCOUNTER A. General Requirements: 1. Stainless-steel construction. 2. Stainless-steel top and side panels. 3. Capacity based on 508 by 508 mm
18、 (20 by 20 inch) racks. 4. Accessories: a. Water-pressure regulating valve. 5. Provide Energy Star qualified appliances. B. Sanitizing Systems: SPEC WRITER NOTE: 1. Select booster heater or chemical sanitizing according to functional requirements and hot-water temperature that is available. 2. Selec
19、t booster heater temperature rise according to hot-water temperature that is available; water delivered to warewasher from booster heater must be 82 degrees C (180 degrees F). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 48 00 - 4 1. Boos
20、ter Heater: Built-in, electric that produces a / 22 degrees C (40 degrees F) / 39 degrees C (70 degrees F) / water-temperature rise. 2. Chemical: Low-temperature chemical sanitizing system. C. Undercounter Dishwashing Machine Units: SYMBOL CAPACITY RACKS/HR. SANITIZING SYSTEM K8010 40 Booster heater
21、 K8011 30 Chemical 2.2 DISHWASHING MACHINES, SINGLE TANK, ELECTRIC A. General Requirements: 1. Stainless-steel construction. 2. Stainless-steel enclosure panels. 3. Control panel. 4. Electric tank heat. 5. Capacity based on 508 by 508 mm (20 by 20 inch) racks. SPEC WRITER NOTE: 1. Select accessories
22、 according to functional requirements and space available. 2. Select booster heater temperature rise according to hot-water temperature that is available; water delivered to warewasher from booster heater must be 82 degrees C (180 degrees F). 6. Accessories: a. Built-in, electric booster heater that
23、 produces a / 22 degrees C (40 degrees F) / 39 degrees C (70 degrees F) / water-temperature rise. b. Water-pressure regulating valve. c. Corner application. d. 686 mm (27 inch) wide door opening to accommodate trays and sheet pans. 7. Provide Energy Star qualified appliances. B. Electric, Single-Tan
24、k Dishwashing Machine Units: SYMBOL CAPACITY RACKS/HR. K8015 53 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 48 00 - 5 2.3 DISHWASHING MACHINES, CONVEYOR, SINGLE TANK, ELECTRIC A. General Requirements: 1. Stainless-steel construction. 2.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA1148002011CLEANINGANDDISPOSALEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-1074821.html