1、11-11 11 40 11 - 1 SECTION 11 40 11 CUSTOM FABRICATED FOODSERVICE EQUIPMENT SPEC WRITER NOTES: 1. Delete between / _ / if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber the paragraphs. 3. Select custom-fabricated equipment according
2、 to usage requirements and local health codes. PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies custom-fabricated food service equipment as follows: /1. Tables./ /2. Prep and scullery sinks. / /3. Pot washer, prep, and scullery sinks. / /4. Hoods, condensate, warewashing./ /5. Urn stands./
3、 1.2 RELATED WORK SPEC WRITER NOTE: Show metal supports for cooking equipment on drawings and specify requirements for supports in Section 05 50 00, METAL FABRICATIONS. A. Metal Supports: Section 05 50 00, METAL FABRICATIONS. B. Warewashing Equipment: Section 11 48 00, CLEANING AND DISPOSAL EQUIPMEN
4、T. C. Waste Disposers: Section 22 42 26, COMMERCIAL DISPOSERS. D. Conveyors: Section 11 40 21, FOOD SERVICE EQUIPMENT-UTILITY DISTRIBUTION SYSTEM. E. Seismic Restraint of Equipment: Section 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS. F. Plumbing Connections: Section 22 05
5、 19, METERS AND GAGES FOR PLUMBING PIPING, Section 22 05 23, GENERAL-DUTY VALVES FOR PLUMBING PIPING, Section 22 05 33, HEAT TRACING FOR PLUMBING PIPING, Section 22 11 00, FACILITY WATER DISTRIBUTION, Section 22 13 00, FACILITY SANITARY SEWERAGE, Section 22 13 23, SANITARY WASTE INTERCEPTORS, Sectio
6、n 22 14 00, FACILITY STORM DRAINAGE, Section 22 66 00, CHEMICAL-WASTE SYSTEMS FOR LABORATORY AND HEALTHCARE FACILITIES and Section 23 11 23, FACILITY NATURAL-GAS PIPING. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 40 11 - 2 G. Electrical
7、 Connections: Section 26 05 11, REQUIREMENTS FOR ELECTRICAL INSTALLATIONS, Section 27 05 11, REQUIREMENTS FOR COMMUNICATIONS INSTALLATIONS and Section 28 05 11, REQUIREMENTS FOR ELECTRONIC SAFETY AND SECURITY INSTALLATIONS 1.3 QUALITY CONTROL A. Manufacturer Qualifications: Approved by NSF Internati
8、onal (NSF) for manufacturing items indicated. B. Installer Qualifications: Experienced in food service equipment installation or supervised by an experienced food service equipment installer. 1. Where required to complete equipment installation, electrician and plumber shall be licensed in jurisdict
9、ion where project is located. SPEC WRITER NOTE: UL Environmental and Public Health (EPH) Classification Mark is currently used by UL to certify compliance with NSF/ANSI standards. Equipment evaluated by UL before 2001 may bear the UL Food Service Product Certification Mark. C. NSF Compliance: Equipm
10、ent bears NSF Certification Mark or UL Classification Mark indicating compliance with NSF/ANSI 2. D. Electrical Components: Listed by UL and marked for intended use. E. Plumbing Fixture Fittings: Comply with ASME A112.18.1. SPEC WRITER NOTE: Retain paragraph and subparagraphs below if required for p
11、roject location. F. Seismic Restraint: 1. Comply with requirements in Section 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS. 2. Comply with applicable guidelines for seismic restraint of kitchen equipment contained in SMACNAs “Kitchen Ventilation Systems and Food Service Equ
12、ipment Guidelines,“ Appendix A. G. In-Use Service: At least one factory-authorized service agency for equipment shall be located in the geographical area of the installation and shall have the ability to provide service within 24 hours after receiving a service call. 1.4 SUBMITTALS A. Submit in acco
13、rdance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 40 11 - 3 B. Shop Drawings: Show dimensions, method of assembly, installation and conditions relating to adjoining work w
14、hich requires cutting or close fitting, reinforcement, anchorage, and other work required for complete installation. C. Operating Instructions: In accordance with requirements in Section 01 00 00, GENERAL REQUIREMENTS. 1.5 WARRANTY Warrant food service equipment to be free from defects in materials
15、and workmanship in accordance with requirements of “Warranty of Construction“, FAR clause 52.246-21. 1.6 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B.
16、ASME International (ASME): A112.18.1-11 . Plumbing Fixture Fittings C. ASTM International (ASTM): A554-10 Welded Stainless Steel Mechanical Tubing A666-10 Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar D. National Association of Architectural Metal Manufacturers
17、 (NAAMM): AMP 500-06 . Metal Finishes Manual E. NSF International/American National Standards Institute (NSF/ANSI): 2-10 . Food Equipment F. Sheet Metal and Air Conditioning Contractors National Association (SMACNA): Kitchen Ventilation Systems and Food Service Equipment Fabrication and Installation
18、 Guidelines, 2001 PART 2 PRODUCTS 2.1 STAINLESS STEEL, GENERAL A. Sheet, Strip, Plate, and Flat Bar: ASTM A 666, Type 304, stretcher leveled. B. Tube: ASTM A 554, Grade MT-304. C. Minimum Specified Thickness: 1. Table / and Counter / Surfaces: 2.0 mm (0.0781 inch). 2. Drainboards: 2.0 mm (0.0781 inc
19、h). 3. Shelf Surfaces: 1.6 mm (0.0625 inch). 4. Sink Bowls: 2.0 mm (0.0781 inch). 5. Legs: 1.6 mm (0.0625 inch). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 40 11 - 4 6. Crossbracing: 1.6 mm (0.0625 inch). D. Finishes: Comply with NAAMMs
20、 AMP 500-505, Metal Finishes Manual. Grind and polish surfaces to produce uniform, directional textured, polished, free of cross scratches. Run grain with long dimension of each piece. 1. Exposed Surfaces: No. 4 finish (bright, directional polish). 2. Concealed Surfaces: No. 2B finish (bright, cold-
21、rolled, unpolished finish). 2.2 COMPONENTS, GENERAL A. Sink Fittings: 1. Faucets: Equip sinks with one faucet per sink bowl, unless otherwise indicated. a. / Deck / Splash / mounted. b. Lever handles. c. Chrome-plated copper alloy. 2. Drains: Equip sinks with 50 mm (2 inch) diameter, nickel-plated b
22、ronze, rotary-handle wastes and stainless-steel strainer plates with chrome-plated brass connected overflows. B. Spray Rinse Assemblies: As specified in Section 22 42 26, COMMERCIAL DISPOSERS. C. Splashes: 1. Where backs of units abut walls, equip with splashbacks. 2. Where units abut walls on sides
23、, equip with side splashes. D. Legs: Fitted to top with 3 mm (1/8 inch) thick flange welded to underside of table/body. 1. Feet: Adjustable, stainless steel, NSF certified. 2. Spacing: Maximum 1825 mm (72 inches) o.c. E. Undercounter Shelves: / Stainless-steel sheet / 25 mm (1 inch) diameter, stainl
24、ess-steel tubing, running left to right, at 100 mm (4 inches) o.c. front to back /. F. Sink Covers: To fit within sink opening; perforated with 10 mm (3/8 inch) holes at 50 mm (2 inches) o.c.; and with turned down edges and two recessed handles. G. Baskets: Stainless-steel wire baskets, 406 by 406 b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA1140112011CUSTOMFABRICATEDFOODSERVICEEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-1074816.html