1、11-11 11 12 00 - 1 SECTION 11 12 00 PARKING CONTROL EQUIPMENT SPEC WRITER NOTES: 1. Delete between /-/ if not applicable to project. Also delete any other items or paragraphs not applicable in section and renumber paragraphs. 2. This section includes parking gate arm and activator units, devices for
2、 card, key, or remote controlled access, and vehicle detection activators. 3. This section is for employee access to restricted employee parking areas. Can not use parking control equipment for patient parking areas. PART 1 GENERAL: 1.1 DESCRIPTION: A. Section Includes: 1. Automatic Barrier Gates. 2
3、. Vehicle Detectors. 3. Card Control Units. 1.2 RELATED WORK: A. Asphaltic paving: Section 32 12 16, ASPHALT PAVING. B. Concrete paving: Section 32 05 23, CEMENT AND CONCRETE FOR EXTERIOR IMPROVEMENTS. C. Concrete foundation work: Section 03 30 00, CAST-IN-PLACE CONCRETE. D. Color and texture: Secti
4、on 09 06 00, SCHEDULE FOR FINISHES. E. Conduit placement for equipment: Section 26 05 33, RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS, Section 27 05 33, RACEWAYS AND BOXES FOR COMMUNICATIONS SYSTEMS and Section 28 05 33, RACEWAYS AND BOXES FOR ELECTRONIC SAFETY AND SECURITY. F. Power supply to disconne
5、ct, junction box, in gate arm unit: Section 26 05 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW), Section 27 10 00, STRUCTURED CABLING and Section 28 05 13, CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY. G. Electrical characteristics and wiring connections: S
6、ection 26 27 26, WIRING DEVICES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 12 00 - 2 1.3 QUALITY CONTROL: A. Qualifications: 1. Approval by Contracting Officer is required of products or service of proposed manufacturer, suppliers, and
7、 installers, and will be based upon submission by Contractor of certification that: a. Installer: Approved by manufacturer of materials and has technical qualifications, experience, trained personnel and facilities to install specified items. b. Manufacturers product submitted has been in satisfacto
8、ry operation, on three installations similar and equivalent in size to this project, for three years. Submit list of installations. 2. Maintenance Proximity: Installer shall maintain a place of business with maintenance facilities not more than two (2) hours normal travel time from project site. 3.
9、UL and NEMA Compliance: Provide internal electrical components required as part of parking control equipment that are listed by UL and comply with applicable NEMA standards. 4. Single-Source Responsibility: Obtain parking control equipment from one source and from a single manufacturer. 1.4 SUBMITTA
10、LS: A. In accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES, submit following: 1. Manufacturers Literature and Data: a. Description of parking control equipment material and accessories to be provided. b. Provide data on operating equipment, characteristics and limitations,
11、and operating temperature ranges. 2. Samples: a. Submit two samples of access cards and security program, illustrating size, and coding method. 3. Shop Drawings and Certificates: Indicate plan layout of equipment access lanes, mounting bolt dimensions, conduit and outlet locations, power requirement
12、s, and conformation of building electrical requirements. Provide Contractor with mounting bolt template in time for installation. 4. Wiring Diagrams: Detailing wiring for parking control equipment operator, signal, and control systems differentiating clearly between manufacturer-installed wiring and
13、 field-installed wiring. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 11 12 00 - 3 a. Show locations of connections to electrical service provided as a unit of work under other Divisions. 5. Maintenance Data: For parking control equipment co
14、mponents for inclusion in Operating and Maintenance Manuals, include the following: a. Maintenance Instructions: Provide manufacturers instructions for maintenance of parking control equipment. 1) Include recommended methods and frequency for maintaining equipment in optimum operating condition unde
15、r anticipated traffic and use conditions. 2) Include precautions against materials and methods that may be detrimental to finishes and performance. 3) Lubrication Schedule and Information: Provide lubrication and periodic maintenance requirement schedules including parts list and parts numbers. 6. O
16、peration Data: Provide operating data for operating equipment, including clock timer, changing security access code, and any other pertinent information required for Government operation. 7. Certificates: Quality Control Certificate Submittals and lists specified in paragraph, QUALIFICATIONS. B. In
17、accordance with Section 00 72 00, GENERAL CONDITIONS, submit following at project closeout: Guaranty. C. In accordance with Section 01 00 00, GENERAL REQUIREMENTS, submit following at project closeout: 1. Project Record Documents: Record actual locations of concealed conduit and vehicle detection ac
18、tivators. SPEC WRITER NOTE: Use Article below if special code, regulation, applies to the project; delete this article if none apply. 1.5 REGULATORY REQUIREMENTS: A. Conform to / applicable /_/ code for fire/ambulance emergency vehicle access. B. Products Requiring Electrical Connection: Listed and
19、classified by / UL / testing firm acceptable to authority having jurisdiction / as suitable for purpose specified and indicated. 1.6 PROJECT CONDITIONS: A. Coordinate placement of conduit, accessories, and power wiring to operating equipment. Provided by IHSNot for ResaleNo reproduction or networkin
20、g permitted without license from IHS-,-,-11-11 11 12 00 - 4 B. Sequence installation to ensure utility connections are achieved in an orderly and expeditious manner. 1.7 DELIVERY, STORAGE AND HANDLING: A. Deliver materials to site in original sealed packages or containers; labeled for identification
21、 with manufacturers name and brand. B. Store materials in weathertight and dry storage facility. Protect from damage due to handling, weather, and construction operations before, during and after installation. 1.8 APPLICABLE PUBLICATIONS: A. Publications listed below form a part of this specificatio
22、n to extent referenced. Publications are referenced in text by basic designation only. B. American Society for Testing Materials (ASTM): A153/A153M-09 Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware. A500-10 Standard Specification for Cold-Formed Welded and Seamless Carb
23、on Steel Structural Tubing in Rounds and Shapes. A653/A653M-10 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Structural (Physical) Quality. C. National Electrical Manufacturers Association (NEMA): MG 1-09(R2010) . Motors and Generators. D. National Fire Pro
24、tection Association (NFPA): 70-11 National Electrical Code. E. Underwriters Laboratories Inc. (UL): Electrical Appliance and Utilization Equipment Directory. 1.9 SYSTEM DESCRIPTION: A. Parking Control System: / Attended / Automatic / operation at entrance and / attended / automatic / operation at ex
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA1112002011PARKINGCONTROLEQUIPMENTPDF